Document Detail


The value of reporting pressure-time integral data in addition to peak pressure data in studies on the diabetic foot: A systematic review.
MedLine Citation:
PMID:  23273847     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
BACKGROUND: In plantar pressure studies on the diabetic foot, pressure-time integral data is often analyzed and reported next to peak pressure data, mostly because of its assumed additional value. The aim was to assess this additional value by systematically reviewing the relevant literature. METHODS: The MEDLINE database was searched for original articles that report both pressure-time integral and peak pressure data measured in the diabetic foot. Eligible articles were assessed according to differences in reported results between both parameters, the quality of discussion and specific conclusions drawn on pressure-time integral data, and the added value of the pressure-time integral data. FINDINGS: All 35 eligible papers described studies on gait. Differences in reported results between parameters were found to be clear, minimal, or absent in 15, 8, and 12 papers, respectively. In 15 papers, the pressure-time integral results were discussed with respect to the peak pressure results, but in only 5 papers the explanation given for reported differences was considered meaningful. Specific conclusions were drawn in 11 papers. Some added value was found in 10 papers, but in all papers one or more limitations to this value applied. INTERPRETATION: The study findings suggest that the added value of reporting pressure-time integral data is limited. Unless clear benefit can be shown such, as that ulceration can be better predicted using pressure-time integral than using peak pressure data, the reporting of pressure-time integral data seems redundant to express the plantar loading in the diabetic foot.
Authors:
S A Bus; R Waaijman
Related Documents :
18002697 - Motion artifact reduction in blood pressure signals using adaptive digital filter with ...
6948627 - Photodetector assessment of velopharyngeal activity.
23413067 - Biomechanical analysis of the calcaneocuboid joint pressure after sequential lengthenin...
17717617 - Physiological and psychological stress reactions in relation to classroom noise.
8549177 - Total respiratory system, lung, and chest wall mechanics in sedated-paralyzed postopera...
3992247 - Adaptation of the membrane lipids of a deep-sea bacterium to changes in hydrostatic pre...
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2012-12-26
Journal Detail:
Title:  Clinical biomechanics (Bristol, Avon)     Volume:  -     ISSN:  1879-1271     ISO Abbreviation:  Clin Biomech (Bristol, Avon)     Publication Date:  2012 Dec 
Date Detail:
Created Date:  2012-12-31     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  8611877     Medline TA:  Clin Biomech (Bristol, Avon)     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Copyright Information:
Copyright © 2012 Elsevier Ltd. All rights reserved.
Affiliation:
Human Performance Laboratory, Department of Rehabilitation, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands. Electronic address: s.a.bus@amc.uva.nl.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Systematic review and meta-analysis of comparative studies reporting early outcomes after robot-assi...
Next Document:  Expression of sulfatases in Rhodopirellula baltica and the diversity of sulfatases in the genus Rhod...