| The technique of detecting systolic and diastolic pressure from the transducer output of a PC-based blood pressure monitoring system. | |
| | |
MedLine Citation:
|
PMID: 17891676 Owner: NLM Status: MEDLINE |
Abstract/OtherAbstract:
|
A pressure to voltage transducer is used along with a cuff, in a PC-based blood pressure and pulse rate monitoring system for human body. During the blood pressure measurement cycle, the output voltage of the pressure to voltage transducer is recorded digitally using a data acquisition system. The recorded data are then analyzed using software routines to determine the blood pressure and pulse rate of the person under test. However, it is difficult to identify the points of systole and diastole correctly from the recorded data. This paper presents the technique that may be used to determine the systolic and diastolic pressure from the collected data. |
| | |
Authors:
|
M S Rahman; R Parveen; K H Kabir |
Related Documents
:
|
20489686 - Arterial stiffness and wave reflections in marathon runners. 986616 - Intraluminal pressure of the small intestine of the unanesthetized dog. 7728846 - Development of a new technique for reducing pressure pulse generation during 308-nm exc... 679436 - Aortic input impedance in heart failure. 7053636 - Recurrent compartment syndrome in the posterior thigh. report of a case. 11740156 - Effect of progesterone on peripheral blood flow in prepubertal female anesthetized pigs. |
Publication Detail:
|
Type: Evaluation Studies; Journal Article Date: 2007-09-24 |
Journal Detail:
|
Title: Computer methods in biomechanics and biomedical engineering Volume: 10 ISSN: 1025-5842 ISO Abbreviation: Comput Methods Biomech Biomed Engin Publication Date: 2007 Dec |
Date Detail:
|
Created Date: 2008-03-31 Completed Date: 2008-04-23 Revised Date: - |
Medline Journal Info:
|
Nlm Unique ID: 9802899 Medline TA: Comput Methods Biomech Biomed Engin Country: England |
Other Details:
|
Languages: eng Pagination: 409-17 Citation Subset: IM |
Affiliation:
|
Bangladesh University of Engineering and Technology, Dhaka, Bangladesh. saifur@eee.buet.ac.bd |
Export Citation:
|
APA/MLA Format Download EndNote Download BibTex |
| MeSH Terms | |
Descriptor/Qualifier:
|
Algorithms* Blood Pressure Determination / instrumentation*, methods Diagnosis, Computer-Assisted / instrumentation*, methods Diastole / physiology* Equipment Design Equipment Failure Analysis Humans Pattern Recognition, Automated / methods Reproducibility of Results Sensitivity and Specificity Systole / physiology* Transducers* |