| A tale of four atrioventricular intervals. | |
| | |
MedLine Citation:
|
PMID: 19897504 Owner: NLM Status: MEDLINE |
Abstract/OtherAbstract:
|
The introduction of new pacing algorithms for preserving intrinsic atrioventricular conduction has made the interpretation of normal pacemaker function at times challenging. Electrocardiographic (ECG) findings in a patient with apparent pacemaker malfunction is presented and interpretation given. During this process, the managed ventricular pacing algorithm is described to interpret the ECG findings and the potential pitfalls of this algorithm is discussed. |
| | |
Authors:
|
Anandaraja Subramanian; Raja J Selvaraj; Douglas Cameron |
Related Documents
:
|
1104364 - Use of atrial and bifocal cardiac pacemakers for treating resistant dysrhythmias. 11248774 - Pacemaker repetitive nonreentrant ventriculoatrial synchronous rhythm. a review. 7616144 - Spontaneous shifts in the sinus node pacemaker complex. 16627454 - Electromechanical synchronization of the heterotopic and native heart by dual atrial st... 12123564 - Endocardial mapping and ablation of tachycardia guided by noncontact balloon catheter m... 83634 - Overdrive pacing for supraventricular tachycardia: a review of theoretical implications... |
Publication Detail:
|
Type: Case Reports; Journal Article Date: 2009-11-06 |
Journal Detail:
|
Title: Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology Volume: 12 ISSN: 1532-2092 ISO Abbreviation: Europace Publication Date: 2010 Mar |
Date Detail:
|
Created Date: 2010-02-22 Completed Date: 2010-05-07 Revised Date: - |
Medline Journal Info:
|
Nlm Unique ID: 100883649 Medline TA: Europace Country: England |
Other Details:
|
Languages: eng Pagination: 441-2 Citation Subset: IM |
Affiliation:
|
Division of Electrophysiology, Department of Cardiology, Toronto General Hospital, University Health Network, 200 Elizabeth Street, Toronto, ON, Canada M5G 2C4. saraja79@yahoo.com |
Export Citation:
|
APA/MLA Format Download EndNote Download BibTex |
| MeSH Terms | |
Descriptor/Qualifier:
|
Aged, 80 and over Algorithms Atrioventricular Block* / diagnosis, physiopathology, therapy Cardiac Pacing, Artificial / adverse effects*, methods* Electrocardiography* Humans Pacemaker, Artificial |
From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine
Previous Document: Value of right ventricular-left ventricular interlead electrical delay to predict reverse remodellin...
Next Document: Fluconazole at subinhibitory concentrations induces the oxidative- and nitrosative-responsive genes ...