Document Detail

The role of transesophageal echocardiography in the intraoperative period.
Jump to Full Text
MedLine Citation:
PMID:  22758616     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
The goal of hemodynamic monitoring and management during major surgery is to guarantee adequate organ perfusion, a major prerequisite for adequate tissue oxygenation and thus, end-organ function. Further, hemodynamic monitoring should serve to prevent, detect, and to effectively guide treatment of potentially life-threatening hemodynamic events, such as severe hypovolemia due to hemorrhage, or cardiac failure. The ideal monitoring device does not exist, but some conditions must be met: it should be easy and operator-independently to use; it should provide adequate, reproducible information in real time. In this review we discuss in particular the role of intraoperative use of transesophageal echocardiography (TOE). Although TOE has gained special relevance in cardiac surgery, its role in major non cardiac surgery is still to be determined. We particularly focus on its ability to provide measurements of cardiac output (CO), and its role to guide fluid therapy. Within the last decade, concepts oriented on optimizing stroke volume and cardiac output mainly by fluid administration and guided by continuous monitoring of cardiac output or so called functional parameters of cardiac preload gained particular attention. Although they are potentially linked to an increased amount of fluid infusion, recent data give evidence that such pre-emptive concepts of hemodynamic optimization result in a decrease in morbidity and mortality. As TOE allows a real time direct visualization of cardiac structures, other potentially important advantages of its use also outside the cardiac surgery operation room can be postulated, namely the ability to evaluate the anatomical and functional integrity of the left and the right heart chambers. Finally, a practical approach to TOE monitoring is presented, based on a local experience.
Authors:
Veronica Gouveia; Paulo Marcelino; Daniel A Reuter
Related Documents :
25461646 - Electrical excitation of the heart in a basal vertebrate, the european river lamprey (l...
25234056 - Tissue doppler, strain and strain rate in ischemic heart disease "how i do it"
16039036 - Epinephrine and vasopressin during cardiopulmonary resuscitation.
10750806 - Sergei s. brukhonenko: the development of the first heart-lung machine for total body p...
21640216 - Effect of clopidogrel pretreatment on ischemic complications of percutaneous coronary i...
12569326 - Prognostic significance of ischemic electrocardiographic changes during adenosine infus...
Publication Detail:
Type:  Journal Article; Review    
Journal Detail:
Title:  Current cardiology reviews     Volume:  7     ISSN:  1875-6557     ISO Abbreviation:  Curr Cardiol Rev     Publication Date:  2011 Aug 
Date Detail:
Created Date:  2012-07-04     Completed Date:  2013-02-11     Revised Date:  2013-07-12    
Medline Journal Info:
Nlm Unique ID:  101261935     Medline TA:  Curr Cardiol Rev     Country:  United Arab Emirates    
Other Details:
Languages:  eng     Pagination:  184-96     Citation Subset:  IM    
Affiliation:
Department of Anesthesiology and Intensive Care Medicine, Klinikum Itzehoe, Germany. gouveia.v@gmx.de
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Cardiac Output
Cardiac Surgical Procedures / methods*
Cardiac Volume
Echocardiography, Transesophageal*
Fluid Therapy / methods
Humans
Monitoring, Intraoperative / methods*
Ventricular Dysfunction, Left / ultrasonography
Comments/Corrections

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine

Full Text
Journal Information
Journal ID (nlm-ta): Curr Cardiol Rev
Journal ID (publisher-id): CCR
ISSN: 1573-403X
ISSN: 1875-6557
Publisher: Bentham Science Publishers
Article Information
Download PDF
© 2011 Bentham Science Publishers
open-access:
Received Day: 15 Month: 2 Year: 2011
Revision Received Day: 18 Month: 2 Year: 2011
Accepted Day: 21 Month: 2 Year: 2011
Print publication date: Month: 8 Year: 2011
Volume: 7 Issue: 3
First Page: 184 Last Page: 196
ID: 3263482
PubMed Id: 22758616
Publisher Id: CCR-7-184
DOI: 10.2174/157340311798220511

The Role of Transesophageal Echocardiography in the Intraoperative Period
Verónica Gouveia1*
Paulo Marcelino3
Daniel A Reuter2
1Department of Anesthesiology and Intensive Care Medicine Klinikum Itzehoe, Germany
2Department of Anesthesiology, Center of Anesthesiology and Intensive Care Medicine, Hamburg-Eppendorf University Medical Center, Hamburg, Germany
3CEDOC, Faculdade de Ciências Médicas, Lisboa
* Address Correspondence to this author at the Department of Anesthesiology and Intensive Care Medicine, Klinikum Itzehoe, Robert-Koch-Str. 2, 25524 Itzehoe, Germany; Tel:/Fax: 04821/7772-3999; E-mail: gouveia.v@gmx.de

INTRODUCTION

Perioperative hemodynamic management during major surgery can be challenging for the anaesthesiologist, especially if hemodynamic instability is likely to occur. For this reason patients are monitored in order to trace several physiological parameters. In the hemodynamically unstable patient, fluid infusion and catecholamine support are the choices of treatment, based on the information retrieved by adequate monitoring. Basic monitoring during anesthesia for surgical procedures consists of electrocardiography, pulse oximetry, non-invasive measurement of blood pressure, and, when general anesthesia is applied, capnometry and -graphy. Perhaps the most commonly used devices for advanced hemodynamic monitoring during major surgery are intravasal catheters for the continuous monitoring of arterial and central venous pressure (CVP) and, in selected cases and according to local experience, the continuous monitoring of cardiac output (CO) using transcardiopulmonary indicator dilution or arterial pulse contour analysis (PiCCO, LiDCO ,Vigileo, PRAM, and others). Pulmonary artery catheters were frequently used in the past, however, its use extremely decreased over the last decade, since several trials in the field of intensive care medicine and perioperative care could not prove any benefit for its use [1,2].

Among the new techniques for intraoperative management Transesophageal Echocardiography (TOE) is considered promising [3]. The unique ability of TOE in direct, real-time visualization of cardiac structures provides an invaluable role in the intraoperative management of cardiac surgery [4-6]. Anaesthesiologists can acquire competence in this field through specific training programmes [7].

Its systematic use in non cardiac surgery seems helpful, but publications in the field are yet scarce [8]. However, in particular in complex non-cardiac procedures, such as liver surgery or even liver transplantation its use can add important information on hemodynamic management [9]. During these procedures, hemodynamic instability frequently occurs because of surgical manipulation, and in particular because of blood loss. Wax et al. [10] analyzed the experience of using TOE during liver transplantation in the United States, and demonstrated that TOE was performed by 86% of anaesthesiologists in some or all liver transplant cases, although most performed only a limited scope examination. Further, only 12% of the care giving anesthesiologists were board certified regarding TOE, and only 1 centre was reported to have a policy related to credentialing requirements for TOE.

However, regarding the use of TOE in the perioperative phase, two basic questions need to be answered: First, which information needs to be gathered by an advanced monitoring device in order to enable successful management of intraoperative hemodynamic incidents; second, it needs to be analyzed, which information can be retrieved from a specific monitoring tool.


TRANSESOPHAGEAL ECHOCARDIOGRAPHY IN CARDIAC SURGERY

In cardiac surgery, transesophageal echocardiography is used with increasing frequency for diagnostic purposes, as well as for perioperative hemodynamic monitoring. The use of TOE in adult as well as in pediatric cardiac surgery has provided a large amount of new information not previously available, and an increasing number of complex procedures also in interventional cardiology are today simply not possible without TOE.

When analyzing the literature the most frequently measured hemodynamic parameters assessed by TOE are cardiac output and left ventricular filling, i.e. preload. Further, TOE is used for functional assessment of the LV by identifying global or regional LV wall motion abnormalities, as well as for the assessment of valvular dysfunctions [11,12,13]. In valve surgery, TOE plays a particular role, because it allows assessing the immediate results of surgical reconstruction or replacement. For example, in during aortic valve replacement, TOE allows sizing the valve annulus and confirming satisfactory function after implantation.

Compared to other monitoring techniques, the use of TOE can be categorized as being very safe because of its minimal invasiveness. Kallmeyer et al. [14] reported the incidence of intraoperative TOE- associated complications in a retrospective case series of 7200 patients in cardiac surgery. The most common TOE- associated complication was severe odynophagia, which occurred in 0.1% of the study population. Other complications included dental injury (0.03%), endotracheal tube malpositioning (0.03%), upper gastrointestinal hemorrhage (0.03%) and esophageal perforation (0.01%) [15,16]. Kremer et al. studied 400 patients using TOE for up to 12 hours during elective cardiac surgery and demonstrated that TOE was associated with fewer complications than intravascular pressure and flow measurements by the use of the pulmonary artery catheter, [17].

A current literature review shows from small to large series of patients in cardiac surgery, that the use of TOE is a valuable instrument in the intraoperative period. Compared to other monitoring techniques TOE had more influence in intra-operative decision making. Bergquist et al. showed that TOE was the single most important guiding factor in 17% of the 587 interventions, which were assessed. Interventions involving fluid administration contributed to 47% of the total clinical decisions. TOE was the most relevant decision tool leading to fluid administration in 30% of cases, compared to only 7% by the pulmonary artery catheter in these cases. In a prospective cohort study, Mishra et al. [18] evaluated 5016 adult patients, 1356 underwent valve procedures and 3660 coronary artery bypass grafting. They observed that in 36% there were TOE- guided hemodynamic interventions, and in 23% TOE was the sole guiding factor initiating therapy. Pierre et al. [19] showed that during cardiac surgery TOE changed in 53% of the cases actual medical therapy and 30% it influenced surgical decisions. In a large series of 12 566 patients undergoing cardiac surgery, studied by Eltzschig et al. [20], the impact of intraoperative TOE on surgical decisions was assessed. In more than 9% intraoperative procedures TOE influenced cardiac surgical decisions.

According to the literature TEE is obviously advisable in cardiac surgery. But available literature also confirms the need for specific training for its use in the perioperative phase.. Guidelines are well defined by the American Society of Echocardiography (ASE) and the Society of Cardiovascular Anaesthesiologists (SCA) [7].


TRANSESOPHAGEAL ECHOCARDIOGRAPHY FOR NON CARDIAC SURGERY

The questions faced by anaesthesiologists during non cardiac surgery are rather different. Hemodynamic instability and rapid changes in volume status (mainly due to acute blood loss) are the most serious complications and challenges for perioperative management.

Most frequently, hemodynamic instability is associated with hypotension and/or arrhythmias. Episodes of hypotension are dangerous. Organ perfusion is rapidly impaired, and intra and post operative complications may appear as result of organ ischemia. Some organs are more sensitive to ischemia, as the case for the central nervous system or the kidneys.

The main issue is the rapid recognition of these life threatening situations, and identification of their causes, which is the basis for adequate treatment [21]. The pathophysiology of hypotension, regardless of aetiology, may be due to cardiac (pump) failure, hypovolemia, or reduced peripheral vascular resistance. For discrimination, one usually needs to determine cardiac output, vascular filling and peripheral vascular resistance. As peripheral vascular resistance is dependent on cardiac output, a normal or increased cardiac output in a patient with hypotension usually indicates a reduced peripheral resistance. So, cardiac output in this setting can be discriminative, identifying patients needing vasopressor therapy. However, unfortunately, at the bedside, pathophysiology is frequently not so easy to recognize because different hemodynamic aberrations can be present in parallel. Even in acute blood loss, reduced peripheral resistance can be present, as for example due to systemic inflammation, along with signs of hypovolemia. Therefore, the assessment of cardiac output and cardiac preload play a central role in advanced intraoperative monitoring.

Transesophageal echocardiography can be helpful and add important information. In experienced hands, the correlation between echocardiography and thermodilution for measurement of cardiac output is generally acceptable [22-23]. Although the focus so far was on the evaluation of cardiac output monitoring by echocardiography, the impact of direct visualization of cardiac structures has so far not extensively studied in non-cardiac surgery. But of course, also in the perioperative care for non-cardiac surgery, for example monitoring left ventricular function, allowing the detection of pump failure, or visualization of right heart chambers, allowing the real-time diagnosis of pulmonary hypertension and overload (pulmonary thromboembolism) can be potentially life-saving. Other advantages can become evident with the regular use of the technique.

In the following, the basic cornerstones of hemodynamic assessment by TEE are discussed.


ASSESSMENT OF CARDIAC OUTPUT

Monitoring of CO has gained particular attention as it is one main determinant of oxygen transport. But if circulatory flow is adequate to fulfil the needs of the end organs, can of course not be determined by its measurement. Perhaps the main use of monitoring CO is to detect changes in this variable over time, especially during episodes of hemodynamic instability and following therapeutic interventions. Considering this main function of CO monitoring, the changes are more important than the absolute values. Other variables provided by the continuous CO monitoring systems, such as the stroke volume variation and systemic vascular resistance index can be also provided directly by TOE. However, systemic vascular resistance can be easily derived from the CO and CVP.

Nonetheless CO alone can not be considered a surrogate for left ventricular function. It depends not only on the left ventricular stroke volume and heart rate, but it is also strongly load-dependent, i.e. cardiac filling (preload) and peripheral vascular resistance (afterload). This means that the sole information on CO does not give an accurate picture of a specific situation. The only exception may be the presence of a normal or high CO in patients with a mean blood pressure lower than 60 mmHg, indicating a low peripheral vascular resistance. However, left ventricular performance is still undetermined.

The gold standard for CO determination are direct measurements of blood flow in the ascending aorta by electromagnetic or ultrasonic flow probes mounted around the aorta (experimental gold standard), or, in the clinical setting, using the Fick principle. However, this technique requires a controlled airway to assess in- and expired gas concentrations. Further, patients need to be hemodynamically stable during the measurement period.

The most common technique used at the bedside is the thermodilution method, an application of the indicator dilution principle, in which the indicator is cold saline [25]. Actually, for many authors this method represents the clinical “gold-standard”, due to its extensive use in the past, often leading to ignorance to methodological limitations of this technique. Further, serious concerns have arise on the routine use of pulmonary artery catheterization in several settings, especially in the critically ill. The available devices for continuous CO measurements, based on dilution methods, have been introduced in medical practice in the recent years [26,27].


MEASUREMENT OF CARDIAC OUTPUT BY ECHOCARDIOGRAPHY

Echocardiography has been studied for several years as a non invasive tool for CO determination. Several technical approaches have been used, both using the transthoracic and transesophageal approach. The comparison between echocardiographic methods for CO evaluation and the more frequently used other monitoring techniques, such as thermodilution is discussed here. Two main approaches of echocardiography are used. The first is provided by esophageal probes, placed on the descending aorta. Pulsed-wave analysis is used, which, after correction for the CO loss in the upper branches of the aorta (usually standardized to 30%), provides a continuous CO determination. These probes are “blind”, i.e. they cannot provide a visualization of cardiac structures. Other methods rely on the classic TOE views, assessing the CO either through Doppler analysis in several places (mitral orifice, left ventricular outflow tract). Considering methodology, they can be divided in Doppler derived measurements, and volumetric assessment of heart chambers. The volumetric approach is based on the determination of end-systolic and end-diastolic ventricular volumes, through a short axis transgastric view, calculating the stroke volume.

Bettex et al. [28] studied 30 patients undergoing cardiac surgery. Several echocardiographical Doppler derived methods were used, namely transmitral, transpulmonary, right and left outflow tract, as were area calculations using transgastric views (Simpson´s rules). The comparator was pulmonary artery thermodilution. Overall a low agreement was observed between the methods. The best echocardiographical method was the Doppler based flow assessment over the left ventricular outflow tract, assuming a triangular shape of valve opening. Stoddard et al. [29] evaluated patients under mechanical ventilation in the ICU, using the transgastric view in order to obtain the pulsed-wave Doppler of the left ventricular outflow tract. A good correlation was found between echocardiography and a simultaneous measurement of CO using thermodilution. Estagnaise et al. [30] performed a study in 22 mechanically ventilated patients, and the echocardiographical method used was the CO obtained in a single plane of the mitral valve. A total of 74 measurements were performed, and a significant correlation was found (r=0.78). More importantly, changes in CO were similar by both methods, concluding that TEE derived CO was capable to trace its changes. Su et al. [31] compared bolus thermodilution and continuous thermodilution methods for CO measurement with Doppler derived esophageal CO, in 24 patients undergoing coronary artery bypass graft surgery. A better agreement was found between continuous thermodilution and esophageal CO (0.84) and was poorer between bolus thermodilution and esophageal CO (0.406). Axler et al. [32] compared a Doppler derived method and a volumetric method of CO determination, comparing both to thermodilution. The best method was the Doppler derived one, especially in the group of patients with sepsis (n=40 out of 55 patients enrolled). The authors concluded that the best option is the left ventricular outflow tract pulsed Doppler CO. Dark et al. [33] performed a meta-analysis on the comparison of 2 available ultrasonographic devices, which use the analysis of the pulsed-wave Doppler of the descending aorta. These devices are the CardioQ and HemoSonic 100. Left ventricular stroke volume is estimated by mean systolic velocity measurement using a nomogram in the CardioQ, and an M-mode echocardiography estimate of aortic diameter using HemoSonic 100. Twenty-one studies analysed CardioQ, and 3 Hemosonic 100, both comparing to thermodilution using a pulmonary artery catheter. In total, these studies involved 314 patients and 2400 paired measurements. A good correlation was found between both methods, with a mean difference of -0.69 to 2.00 l/min. The authors concluded that there is a good agreement between both echocardiographical methods and thermodilution CO. Gola et al. [34] analysed the accuracy of Doppler measurements in low output states, as in patients with congestive heart failure. A total of 73 patients who underwent evaluation for cardiac transplantation with dilated cardiomyopathy were evaluated. Simultaneous right heart catheterization with determination of CO through the Fick method, and a transthoracic echocardiogram with CO determination using the left ventricular outflow tract pulsed-Doppler analysis were performed. The correlation between thermodilution and Fick was 0.81, and 0.90 for the Fick method vs. echocardiography. In patients with significant tricuspid regurgitation (n=34) the r value for the agreement between the Fick method and thermodilution was 0.68, and 0.86 for the agreement between echocardiography and the Fick method. The authors concluded that the presence of significant tricuspid regurgitation influences significantly the accuracy of thermodilution CO. Also acceptable agreements between CO measurements with transcardiopulmonary thermodilution and echocardiography were described [35]. In a recent study performed by our group in liver transplant patients [36], we observed an agreement between CO determined by transthoracic echocardiography using the pulsed-wave Doppler analysis of the left ventricular outflow tract and simultaneous bolus thermodilution of 97% (r=0.97). The higher differences were observed in high output states (patients with cirrhosis), which is in accordance to earlier reports, linked to the limitations of pulsed-wave Doppler to detect higher flow velocities. Also, a significant number of patients were hypothermic immediately after surgery, with central temperatures frequently between 32 to 34 degrees Celsius, which increases errors in measurement of the thermodilution techniques. Similar results in liver transplant patients were described by Boucaud et al. [37]. Comparing the new techniques for CO assessment, Nissen and co-workers [38] compared CO obtained through arterial pulse contour analysis and thermodilution in liver transplant patients. They also described a good agreement between the techniques.

Another method to determine CO using TOE is the measurement through the mitral pulsed-Doppler [40]. In this method mitral valve annulus is used as a surrogate for cross-sectional area. The accuracy of determining stroke volume through the mitral valve has not been accurately investigated so far. The mitral valve orifice does not have a perfect geometrical shape, and it is therefore not the preferred structure for CO determination. Data published on this technique are solely from the transthoracic approach. However, one limitation of all echocardiographic techniques for CO determination is the operator dependency, which includes both intra-observer variability, as well as inter-observer variability. This further stresses the need profound and continuous education and training, when using these techniques.


ASSESSMENT OF VOLUME STATUS AND GUIDING VOLUME THERAPY

The assessment of volume status is a cornerstone of perioperative hemodynamic management. Monitoring filling pressures, i.e. central venous pressure and pulmonary artery occlusion pressure (PAOP) were the “standard” methods used for decades. However, these static, pressure-based parameters are now under serious criticism. Past concepts of fluid and volume therapy in several contexts, including the intraoperative period, based on the achievement of higher than normal physiologic filling pressures. By that, adequate volume status, and therefore maintenance of adequate cardiac output should be assured [42]. But the limitations of these parameters are now well characterized. Cardiac filling pressures do not allow predicting the increase in intravascular volume and cardiac output [43,44,45]. This means that a low filling pressure can not indicate that volume administration will lead to an increase in intravascular volume or cardiac output. Several factors contribute to this inability of the filling pressures to serve as reliable parameters of preload or volume responsiveness, which includes their dependency on cardiac compliance (i.e. diastolic properties of the heart), on changes in intrathoracic pressure during mechanical ventilation, on the hemodynamic consequences of positive end-expiratory pressure (PEEP) or intra-abdominal pressure. Interestingly, the concept of using filling pressures as parameters of cardiac preload and volume responsiveness was even questioned in healthy individuals [46]. The actual concepts of volume responsiveness use a set of parameters that can accurately predict an increase in CO, due to volume administration. These are the so called dynamic parameters of volume responsiveness [43,47].

However, also the global question, whether fluid restriction or a more liberal approach of perioperative fluid and volume therapy should be aimed, has extensively been discussed within the last decade. In sepsis, a situation characterized by an increased leak of fluid to extravascular space, early and “goal-directed” hemodynamic stabilization, i.e. also in particular volume loading in the early phase is associated with improved outcome. In the recent years several groups of investigators had provided evidence that in the perioperative period, an excess of fluid can be harmful in particular because of edema formation [48]. More recently, Brandstrup et al. [49] conducted a study of 172 patients, monitoring the weight gain in the postoperative period of colorectal surgery. In the patients subjected to restricted fluid administration, assessed by weight gain, a lower number of complications could be observed, including cardiopulmonary (7% vs 24%), and tissue-healing (16% vs. 31%) complications. The same findings were observed by Walsh et al. [50], in which the authors describe a decreased number of complications after major gastrointestinal surgery, mostly performed in ASA 2-3 patients. Further, Adesanya et al. [51], described a beneficial effect in a cohort of 41 patients undergoing vascular surgery. In liver transplant patients the beneficial effect of a restrictive fluid regimen is also described by Jiang et al. [52]. In 62 patients, these authors observed that a negative fluid balance <500ml in the first 3 days after surgery was independently associated with post-operative complications. Also the effect of the amount of fluid in different organs and healing process was studied. Marjanovic et al. [53] demonstrated that the amount of crystalloid infused influenced the intestinal anastomotic stability. In a rat model they observed a bursting cardiac output in the high volume group as well as tissue oedema. Reports of such oedema and bowel swelling are often observed in our patients, impeding surgery, and increasing the probability of complications. In an animal model, Hiltebrand et al. [54] studied tissue oxygen pressure in the small bowel and colon under different fluid regimens. In this model, no difference was found, and the authors suggest efficient auto-regulation of intestinal blood flow. Ozmen et al. [55] also studied the effects of large fluid infusion in an animal model, observing the deleterious effects of larger amounts of extravascular fluids. The influence of excessive fluid administration in several tissues was also confirmed by other authors [55-62].

Several meta-analyses support the previous data. Rahbari et al. [62] observed that a restrictive and goal-directed fluid therapy rather than standard regimens are linked to a better outcome in colorectal surgery. However, the decisive point is that infusion regimens within the single studies were not comparable. What was defined in one study to be “fluid restrictive”, was already “liberal” in other studies [63], and vice versa [61], making the final drawing of conclusions out of these studies difficult [64]. Further, the type of fluid used for a) fluid replacement (i.e. compensation of extravascular and intracellular fluid deficits), and b) intravascular volume deficits (i.e. hypovolemia due to blood loss) has to be taken into consideration, when analyzing these data [65]. On the other hand, an increasing number of studies within the last decade repeatedly gave evidence that early and goal-directed hemodynamic optimization in the perioperative phase with the aim to optimize stroke volume and cardiac output mainly by optimizing cardiac preload (i.e. volume loading) reduces postoperative complications [66-73]. These findings were recently strengthened by a meta-analysis conducted by Hamilton et al. [74]. Those authors showed that a pre-emptive strategy focusing on interventions targeted to optimize major hemodynamic parameters (i.e. stroke volume and cardiac output) in fact can reduce not only postoperative morbidity, but also mortality. However, it needs to be pointed out that in all of these studies, the defined end-points of hemodynamic optimization (hemodynamic goals) were not uniform. Even where hemodynamic parameters like CO output or oxygen delivery were evaluated, an increase in these parameters cannot be directly be indicative of a positive influence. Further, originally the dynamic parameters of volume responsiveness were described to optimize preload in the hemodynamically unstable patient, i.e. in patients with low cardiac output and/or hypotension. Therefore, additional volume loading in a hemodynamically stable patient free of catecholamine support just because of the presence of a parameter indicating volume responsiveness may potentially lead to non-necessary volume- fluid application with the risk of edema formation.


TOE AND DYNAMIC CONCEPTS OF FLUID INFUSION IN THE OPERATING ROOM

By far the most assessed echocardiographical technique for assessment of volume status is the evaluation of the inferior vena cava, i.e. its diameter as a “static” parameter of preload, as well as its ventilation-induced changes, reflecting a “dynamic” parameter of volume responsiveness. In several settings, this was found to be easy to assess, and effective in guiding fluid infusion [75-78]. But its main limitation for perioperative use is that it is although recently described by the use of TEE, mainly a transthoracic echocardiographical approach [79]. As transesophageal echocardiography is the main tool in the operating room, parameters derived from this approach are more extensively studied. Here, the most commonly used parameter for left ventricular preload assessment is left ventricular end-diastolic area (LVEDA). However, LVEDA is also a static assessment of preload, not allowing assessing volume responsiveness [43]. However, assessment of volume responsiveness by functional parameters based on heart-lung interactions under mechanical ventilation is also possible with echocardiography, mainly by techniques using pulsed-wave Doppler within the left ventricular outflow tract or the descending aorta. Using TOE, the left ventricular outflow tract is assessed by deep the transgastric view. The validity of aortic flow measurements and its ventilation induced variations by transesophageal Doppler was broadly evaluated vs. the more widely used systems of continuous cardiac output measurement within the last years, however with varying results. Biais et al. [80] found acceptable limits of agreement between stroke volume variation derived by arterial pulse contour analysis using the FlowTrac/Vigileo device and transesophageal aortic flow Doppler. In contrast, Belloni et al. [81] showed that there was not a good correlation between pulse contour derived stroke volume variation using the LiDCO device and transesophageal parameters, including aortic flow-derived stroke volume variation and end-diastolic and end-systolic left ventricular areas. This discrepancy could also be impressively demonstrated in a small series of cardiac surgery patients, in which both, Doppler derived measurements of beat to beat stroke volume, and those derived from a peripheral (radial artery) arterial pulse contour signal were compared against measurements with a flow probe placed around the aorta (i.e. gold standard measurements) under acute changes in preload [82]. Also Gouvea et al. [83], reported in 15 patients undergoing liver transplantation that pulse pressure variation, proclaimed as one parameter for preload optimization in Doppler-guided hemodynamic strategies, failed to assess volume responsiveness in this group of patients.

Besides this ongoing discussion upon accuracy of the less invasive approaches of cardiac output monitoring by pulse contour analysis and Doppler techniques, a multitude of clinical outcome studies using these beat-to-beat monitoring devices have been published within the last years. Diaper et al. [84] used esophageal Doppler monitoring to guide fluid therapy in 127 high-risk patients undergoing lung surgery due to cancer, concluding that this approach may valuable for this purpose. Goddard et al. [85] studied 128 patients undergoing colorectal surgery and compared CVP-guided and Doppler-guided fluid infusion. They found that in the Doppler-guided fluid therapy arm there was a lower hospital stay and, by authors’ judgement, a more preferable hemodynamic situation reflected by higher oxygen delivery and cardiac output. In another setting, where fluid infusion is critical, Benes et al. [86] evaluated a Doppler-guided protocol in multiple trauma patients, concluding that these patients presented lower levels of blood lactate. Walsh et al. [87] performed a meta-analysis of 4 studies, 393 patients undergoing abdominal surgery, comparing Doppler-guided fluid administration and standard fluid infusion. In the arm of Doppler guided fluid therapy there were fewer postoperative complications, shorter hospital stay, but the amount of fluid infused did not differ significantly. As the authors pointed out a cost-effective analysis between Doppler guided therapy and restrictive fluid regimens is required. In another meta-analysis performed by Abbas et al. [88], the same findings are described, including a beneficial effect of Doppler-guided fluid therapy in early outcomes in patients undergoing abdominal surgery. However, CO and central hemodynamic parameters could not be the sole parameters in guiding intra operative therapy in the future [89].


LEFT VENTRICULAR FUNCTION ASSESSMENT

There is a large amount of literature regarding the use of echocardiography for risk stratification before surgery [90,91]. But its use for the assessment of both left and right ventricular performance in the operating theatre besides for cardiac surgery procedures has not been broadly evaluated so far. However, the possible additional advantages of the perioperative use of transesophageal echocardiography, i.e. the anatomical and functional evaluation of cardiovascular structures can often have clinically highest relevance. An excellent example is the report by Cavallaro et al. [92], who described systolic anterior wall motion (SAM, dynamic left ventricular obstruction) causing hemodynamic instability. Although a feature of hypertrophic cardiomyopathy, in conditions of extreme hypovolemia, as can be found in severe acute haemorrhage, it may cause relevant hypotension, which can be corrected by volume infusion. Interestingly, this is phenomenon not restricted to patients with left ventricular hypertrophy.

However, several issues need to be discussed, when transesophageal echocardiography should be recommended as a “monitoring device” on a broader basis in the perioperative phase. It is obvious that complex, time consuming methods, requiring assessment of multiple single parameters or equations will not be helpful in an acute setting of hemodynamic instability in the operating theatre, where immediate therapeutic consequences are needed. Skiles [93] discussed several methods for the assessment of left ventricular performance. However they all rely on complex measurements or require specific software for analysis. Perrino et al. [94] described an automated echocardiographical analysis method for serial intraoperative measurements in a study conducted in 16 patients undergoing non cardiac surgery. However, clear recommendations on the structured use of transesophageal echocardiography in non-cardiac surgery are scarce.

In the following we describe a standardized approach implemented at Hospital Curry Cabal, Lisbon, for routine assessment of biventricular performance in patients undergoing major non-cardiac surgery, mostly liver surgery and liver transplantation.


AN EXPERIMENTAL PROTOCOL

In Hospital Curry Cabral, a public institution in Lisbon, an experimental protocol was used to establish the feasibility of TOE with direct visualization of cardiac structures as a monitoring tool in patients undergoing major non-cardiac surgery. In a first step, the three clinically most relevant items of echocardiographic evaluation for perioperative care were defined. This was the assessment of CO, of volume status (and its changes as in particular seen in acute blood loss), and of left ventricular performance.

The usual monitoring tools were the continuous monitoring of arterial pressure and central venous pressure, and, in selected cases, additionally the continuous monitoring of cardiac output using PiCCO system.

We defined a standardized study protocol for TOE assessment, which had to be used perioperatively. It should be on the one hand easy enough to be applied during clinical routine, but on the other hand should also provide the care giving anaesthesiologist clinical relevant and reproducible information on cardiac function. On that basis the following sets of measurements were chosen: First the left ventricular influx by evaluation of the mitral E/A ratio in the 4-chamber view was analysed. Further, left ventricular CO was assessed by measuring the mitral velocity time integral (VTI), calculating the stroke volume index (SVI) and multiplying it by heart rate Fig. (1). Necessary information upon the width of the mitral valve orifice was measured in the same view Fig. (2). In the same 4-chamber view a measurement of the external mitral annulus systolic excursion (MAPSE) was registered Fig. (3). Then the probe was slightly retracted, in order to visualize the left atrium (LA), and to determine diameter and area of the left atrium in the aortic valve plane Fig. (4). Afterwards, the probe was repositioned for the assessment of the right atrium and ventricle. In particular the right atrial area was measured Fig. (5). Finally, the probe was slightly retracted, in order to visualise the superior vena cava (SVC), where the respiratory changes were measured (maximum and minimum dimensions, and their ratio; the SVC index was calculated: maximum dimension – minimum dimension x 100 / maximum dimension) Fig. (6). Those hemodynamic assessments using TOE had to be performed every 15 minutes or whenever considered necessary.

Data from 17 patients was gathered, submitted to liver surgery, 6 of them to liver transplantation. Here we found a good correlation between CO obtained with PiCCO system using transcardiopulmonary thermodilution and mitral valve CO (r=0.84, Figs. (7 and 8)); acute blood loss causing hypotension and requiring red packed cells transfusion, was earlier detected by changes in LA dimensions than by changes in CVP; further, TOE allowed to directly assess left ventricular performance The use of MAPSE as a monitoring parameter for left ventricular performance has been previously validated in several studies [95,96].

This represents first preliminary experiences with such a standardized protocol for perioperative TOE examination. Further data are needed from a larger number of patients in a prospective study to evaluate in more detail the usefulness of TOE monitoring during major non-cardiac surgery. This also comprises assessment of acute right heart dysfunction, as seen for example in acute pulmonary embolism. Also, the use of TOE is not free from potential complications, although the reported rate of occurrence is low [97,98]. In the case series described here, its use was safe with no complications. Only in one patient, the introduction of the probe needed to be facilitated by the use of a laryngoscope. Further, the assessment of calculated parameters, such as CO, could be used in an automated mode, which would further facilitate clinical utility.

In conclusion, TOE with a direct visualization of cardiac structures has the potential to provide important information on cardiovascular function during non-cardiac surgery, relevant to hemodynamic management. Its widespread use and increasing experience intraoperatively is desirable.


REFERENCES
1. Connors AF Jr,Speroff T,Dawson NV,et al. The effectiveness of right heart catheterization in the initial care of critically ill patients. SUPPORT InvestigatorsJAMAYear: 199627611889978782638
2. Sandham JD,Hull RD,Brant RF,et al. Canadian Critical Care Clinical Trials GroupA randomized, controlled trial of the use of pulmonary-artery catheters in high-risk surgical patients N Engl J MedYear: 2003348151412510037
3. Oxorn D. Non-invasive imaging. Intraoperative echocardiographyHeartYear: 20089412364318703702
4. Minhaj M,Patel K,Muzic D,et al. The effect of intraopeative trasesophageal echocardiography on surgical managementJ Cardiothorac Vasc AnesthYear: 200721800418068055
5. Kovlev N,Brase R,Swanevelder J,et al. The influence of trnasesophageal echocardiography on intraoperative decision making. A European multicentre studyAnaesthesiaYear: 199853767739797521
6. Klein AA,Snell A,Nashef SA,Hall RM,Kneeshaw JD,Arrowsmith JE. The impact of intraoperative transesophageal echocardiography on cardiac surgical practiceAnaesthesiaYear: 20096494795219686478
7. Calahan MK,Abel M,Goldman M,et al. American Society of echocardiography and Society of cardiovascular anesthesiologists task force guidelines for training in perioperative echocardiographyAnesth AnalgYear: 2002941384812031993
8. Catena E,Mele D. Role of intraoperative transesophageal echocardiography in patients undergoing noncardiac surgeryJ Cardiovasc Med (Hagerstown)Year: 20089993100318799961
9. Ozier Y,Klinck J. Anesthetic management of hepatic transplantationCurr Opin AnaesthesiolYear: 20082139140018458561
10. Wax DB,Torres A,Scher C,Leibowitz AB. Transesophageal echocardiography utilization in high volume liver transplantation centers in the United StatesJ Cardiothorac Vasc AnesthYear: 200822811318834818
11. Matsumoto M,Oka Y,Strom J,et al. Applicationof transesophageal echocardiography to continuous intraoperativ monitoring of left ventricular performanceAm J CardiolYear: 1980461951057386399
12. Alan J,et al. Bryan, Benico Barzilai.Current Review Transesophageal echocardiography and adult cardiac operationsAnn Thorac SurgYear: 19955977397887737
13. Reichert SL,Visser CA,Moulijn AC,et al. Intraoperative transesophageal color-coded Doppler echocardiography for evaluation of residual regurgitation after mitral valve repairJ Thorac Cardiovasc SurgYear: 19901005756612232837
14. Kallmeyer IJ,Collard CD,Fox JA,et al. The safety of intraoperative transesophageal echocardiography: a case series of 7200 cardiac surgical patientsAnesth AnalgYear: 20029512556
15. Sheikh KH,de Bruijn NP,Rankin JS,et al. The utility of transesophageal echocardiography and Doppler color flow imaging in patients undergoing cardiac valve surgeryJ Am Coll CardiolYear: 1990152363722299078
16. Alan J,et al. Bryan, Benico Barzilai. Current Review Transesophageal echocardiography and adult cardiac operationsAnn Thorac SurgYear: 19955977397887737
17. Kremer P,Cahalan M,Beaupre P,et al. Intraoperativ monitoring using transesophageal 2- dimensional echocardiographyAnaesthesistYear: 198534311173993897
18. Mishra M,Chauhan R,Sharma KK,et al. Real-time intraoperative transesophageal echocardiography. How useful?Experience of 5016 cases
19. Pierre Couture,André Y,et al. Denault. Impact of routine use of intraoperative transesophageal echocardiography during cardiac surgeryCan J AnesthYear: 20004720610626713
20. Eltzschig HK,Rosenberger P,Löffler M,et al. Impact of intraoperative transesophageal echocardiography on surgical decisions in 12 666 patients undergoing cardiac surgeryAnn Thorac SurgYear: 2008853852318291155
21. Bergquist BD,Bellows WH,Leung JM,et al. Transesophageal echocardiography in myocardial revascularization: II. Influence on intraoperative decision makingAnesth AnalgYear: 19968261139458638781
22. Savino JS,Troianos CA,Aukburg S,Weiss R,Reichek N. Measurement of pulmonary blood flow with transesophageal echocardiography two-dimensional and doppler ecocardiographyAnesthYear: 19917544551
23. Muhiudeen IA,Kuecherer HF,Lee E,et al. Intraoperative estimation of cardiac output by transesophageal pulsed doppler echocardiographyAnesthYear: 199174914
24. Marino PL. Respiratory gas transport. The ICU Book, Chapter 10Year: 19982nd edPensylvania, USAWilliams & Wilkins15465
25. Reuter DA,Huang C,Edrich T,Sherman SK,Eltzschig HK. Cardiac output monitoring using indicator dilution techniques: basics, limits, and perspectivesAnesth AnalgYear: 20105462231
26. Linton RA,Band DM,Haire KM. A new method of measuring cardiac output in man using lithium dilutionBr J AnaesthYear: 19937166
27. Uchino S,Bellomo R,Morimatsu H,et al. Pulmonary artery catheter versus pulse contour analysis: a prospective epidemiological studyCrit CareYear: 2006106R17417169160
28. Bettex DA,Hinselmann V,Hellermann JP,Jenni R,Schmid ER. Transesophageal echocardiography is unreliable for cardiac output assessment after cardiac surgery compared with thermodilutionAnaesthesiaYear: 20045911849215549977
29. Stoddard MF,Prince CR,Ammash N,Goag JL,Vogel RL. Pulsed Doppler transesophageal echocardiographic determination of cardiac output in human beings: comparision with thermodilution techniqueAm Heart JYear: 1993126956628213455
30. Estagnaise P,Djedaini K,Mier L,Coste F,Dreyfuss D. Measurement of cardiac output by transesophageal echocardiography in mechanically ventilated patients. Comparision with thermodilutionIntensive Care MedYear: 19972375399290989
31. Su NY,Huang CJ,Tsai P,Hsu YW,Hung YC,Cheng CR. Cardiac output measurement during cardiac surgery: esophageal Doppler versus pulmonary artery catheterActa Anaesthesiol SinYear: 2002401273312434609
32. Axler O,Megarbane B,Lentschener C,Fernandez H. Comparison of cardiac output measured with echocardiographic volumes and aortic Doppler methods during mechanical ventilationIntensive Care MedYear: 2003292081712541152
33. Dark PM,Singer M. The validity of trans-esophageal Doppler ultrasonography as a measure of cardiac output in critically ill adultsIntensive Care MedYear: 20043020606615368037
34. Gola A,Pozzoli M,Capomolla S,et al. Comparision of Doppler echocardiography with thermodilution for assessing advanced heart failureAm J CardiolYear: 19967870712
35. Hofer CK,Ganter MT,Matter-Ensner S,et al. Volumetric assessment of left heart preload by thermodilution: comparing the PiCCO-VoLEF system with transoesophageal echocardiographyAnaesthesiaYear: 2006Month: 4 6143162116548948
36. Marcelino P,Germano N,Marum S,Fernandes AP,Ribeiro P,Lopes MG. Haemodynamic parameters obtained by transthoracic echocardiography and Swan-Ganz catheter: a comparative study in liver transplant patientsActa Med PortYear: 200619319720517234080
37. Boucaud C,Bouffard Y,Dumortier J,et al. Transoesophageal echo-Doppler vs. thermodilution cardiac output measurement during hepatic vascular exclusion in liver transplantationEur J AnaesthesiolYear: 200825485918298871
38. Nissen P,Van Lieshout JJ,Novovic S,Bundgaard-Nielsen M,Secher NH. Techniques of cardfiac output measurement during liver transplantation: arterial pulse wave versus thermodilutionLiver TransplYear: 2009152879119242994
39. Dark PM,Singer M. The validity of trans-esophageal Doppler ultrasonography as a measure of cardiac output in critically ill adultsIntensive Care MedYear: 2004302060615368037
40. Miller W,Richard KL,Crawford MH. Accuracy of mitral Doppler echocardiographic cardiac output determinations in adultsAm Heart JYear: 1990591337
41. Roeck M,Jakob SM,Boehlen T,et al. Change in stroke volume in response to fluid challenge: assessment using esophageal DopplerIntensive Care MedYear: 20032916172014635624
42. McKinley BA,Sucher JF,Todd SR,et al. Central venous pressure versus pulmonary artery catheter-directed shock resuscitationShockYear: 20093254637019829240
43. Michard F,Teboul JL. Predicting fluid responsiveness in ICU patients: a critical analysis of the evidenceChestYear: 20021212000812065368
44. Michard F,Reuter DA. Assessing cardiac preload or fluid responsiveness? It depends on the question we want to answerIntensive Care MedYear: 200329139612827236
45. Andritsos MJ,Park K. Advantages and limitations of static parameters of fluid loadingInt Anesthesiol ClinYear: 201048112120065723
46. Kumar A,Anel R,Bunnell E,et al. Pulmonary artery occlusion pressure and central venous pressure fail to predict ventricular filling volume, cardiac performance, or the response to volume infusion in normal subjectsCrit Care MedYear: 2004323691915090949
47. Santry HP,Alam HB. Fluid resuscitation: past, present, and the futureShockYear: 20103332294120160609
48. Lowell JA,Schifferdecker C,Driscoll DF,Benotti PN,Bistrian BR. Postoperative fluid overload: not a benign problemCrit Care MedYear: 199018728332364713
49. Brandstrup B,Tønnesen H,Beier-Holgersen R,et al. Effects of intravenous fluid restriction on postoperative complications: comparison of two perioperative fluid regimens: a randomized assessor-blinded multicenter trialDanish Study Group on Pe-rioperative Fluid Therapy
50. Walsh SR,Tang TY,Farooq N,Coveney EC,Gaunt ME. Perioperative fluid restriction reduces complications after major gastrointestinal surgerySurgeryYear: 20081434466818374042
51. Adesanya A,Rosero E,Timaran C,Clagett P,Johnston WE. Intraoperative fluid restriction predicts improved outcomes in major vascular surgeryVasc Endovascular Surg 2008Year: 20094265316
52. Jiang GQ,Peng MH,Yang DH. Effect of perioperative fluid therapy on early phase prognosis after liver transplantationHepatobiliary Pancreat Dis IntYear: 2008743677218693171
53. Marjanovic G,Villain C,Juettner E,zur Hausen A,Hoeppner J,Hopt UT,Drognitz O,Obermaier R. Impact of different crystalloid volume regimes on intestinal anastomotic stabilityAnn SurgYear: 2009Month: 2 2492181519212167
54. Hiltebrand LB,Kimberger O,Arnberger M,Brandt S,Kurz A,Sigurdsson GH. Crystalloids versus colloids for goal-directed fluid therapy in major surgeryCrit CareYear: 2009132R4019302713
55. Ozmen S,Kusza K,Ulusal BG,Pryor L,Siemionow M,Zins JE. Hemodynamic changes and fluid shifts after large-volume fluid infiltration: results from a porcine modelAnn Plast SurgYear: 2010Month: 1 64183819801916
56. Raue W,Haase O,Langelotz C,Neuss H,Müller JM,Schwenk W. Influence of pre-operative fluid infusion on volume status during oesophageal resection--a prospective trialActa Anaesthesiol ScandYear: 2008Month: 10 52912182518823460
57. Vega D,Badami CD,Caputo FJ,Watkins AC,Lu Q,Xu da Z,Berezina TL,Zaets SB,Feketeova E,Deitch EA. The influence of the type of resuscitation fluid on gut injury and distant organ injury in a rat model of trauma/hemorrhagic shockJ TraumaYear: 2008Month: 8 6524091418695480
58. Rushing GD,Britt LD. Reperfusion injury after hemorrhage: a collective reviewAnn SurgYear: 2008Month: 6 24769293718520219
59. Hiltebrand LB,Pestel G,Hager H,Ratnaraj J,Sigurdsson GH,Kurz A. Perioperative fluid management: comparison of high, medium and low fluid volume on tissue oxygen pressure in the small bowel and colonEur J AnaesthesiolYear: 2007Month: 11 24119273317582246
60. Kimberger O,Arnberger M,Brandt S,Plock J,Sigurdsson GH,Kurz A,Hiltebrand L. Goal-directed colloid administration improves the microcirculation of healthy and perianastomotic colonAnn SurgYear: 2003Month: 11 2385641814578723
61. Boldt J,Suttner S,Brosch C,Lehmann A,Röhm K,Mengistu A. The influence of a balanced volume replacement concept on inflammation, endothelial activation, and kidney integrity in elderly cardiac surgery patientsIntensive Care MedYear: 2009Month: 3 3534627018807007
62. Rahbari NN,Zimmermann JB,Schmidt T,Koch M,Weigand MA,Weitz J. Meta-analysis of standard, restrictive and supplemental fluid administration in colorectal surgeryBr J SurgYear: 2009Month: 4 9643314119283742
63. Bundgaard-Nielsen M,Secher NH,Kehlet H. 'Liberal' vs 'restrictive' perioperative fluid therapy--a critical assessment of the evidenceActa Anaesthesiol ScandYear: 20095378435119519723
64. Jacob M,Chappell D,Rehm M. Clinical update: perioperative fluid managementLancetYear: 20073691984617574081
65. Strunden MS,Heckel K,Goetz A,Reuter DA. Perioperative fluid and volume management: physiological basis, tools and strategiesAnnals-Intensive-CareYear: 20112
66. Walsh SR,Tang T,Bass S,Gaunt ME. Doppler-guided intra-operative fluid management during major abdominal surgery: systematic review and meta-analysisInt J Clin PractYear: 20086234667018031528
67. Kobayashi M,Ko M,Kimura T,et al. A. Perioperative monitoring of fluid responsiveness after esophageal surgery using stroke volume variationExpert Rev Med DevicesYear: 200853311618452380
68. Buettner M,Schummer W,Huettemann E,Schenke S,van Hout N,Sakka SG. Influence of systolic-pressure-variation-guided intraoperative fluid management on organ function and oxygen transportBr J AnaesthYear: 20081012194918511439
69. Lopes MR,Oliveira MA,Pereira VO,Lemos IP,Auler JO Jr,Michard F. Goal-directed fluid management based on pulse pressure variation monitoring during high-risk surgery: a pilot randomized controlled trialCrit CareYear: 2007115R10017822565
70. Mayer J,Boldt J,Mengistu AM,Röhm KD,Suttner S. Goal-directed intraoperative therapy based on autocalibrated arterial pressure waveform analysis reduces hospital stay in high-risk surgical patients: a randomized, controlled trialCrit CareYear: 2010141R1820156348
71. Van der Linden PJ,Dierick A,Wilmin S,Bellens B,De Hert SG. A randomized controlled trial comparing an intraoperative goal-directed strategy with routine clinical practice in patients undergoing peripheral arterial surgeryEur J AnaesthesiolYear: 20102797889320613538
72. Giglio MT,Marucci M,Testini M,Brienza N. Goal-directed haemodynamic therapy and gastrointestinal complications in major surgery: a meta-analysis of randomized controlled trialsBr J AnaesthYear: 200910356374619837807
73. Phan TD,Ismail H,Heriot AG,Ho KM. Improving intraoperative outcomes: fluid optimization with the esophageal Doppler monitor, a metaanalysis and reviewJ Am Coll SurgYear: 20082079354119183542
74. Hamilton MA,Cecconi M,Rhodes A. A Systematic Review and Meta-Analysis on the Use of Preemptive Hemodynamic Intervention to Improve Postoperative Outcomes in Moderate and High-Risk Surgical PatientsAnesth AnalYear: 2010
75. Michard F,Lopes MR,Auler JO. Pulse pressure variation: beyond the fluid management of patients with shockJr Crit CareYear: 2007113131
76. Barbier C,Lubieres Y,Schmit C,et al. Respiratory changes in vena cava diameter are helpful in predicting fluid responsiveness in ventilated septic patientsIntensive Care MedYear: 2004301740174615034650
77. Marcelino P,Fernandes AP,Marum S,Ribeiro JP. Non-invasive evaluation of central venous pressure by echocardiographyRev Port CardiolYear: 20022121253311963282
78. Yanagawa Y,Sakamoto T,Okada Y. Hypovolemic shock evaluated by sonographic measurement of the inferior vena cava during resuscitation in trauma patientsJ TraumaYear: 20076361245818212645
79. Arthur ME,Landolfo C,Wade M,Castresana MR. Inferior vena cava diameter (IVCD) measured with transesophageal echocardiography (TEE) can be used to derive the central venous pressure (CVP) in anesthetized mechanically ventilated patientsEchocardiographyYear: 200926140919054047
80. Biais M,Nouette-Gaulain K,Roullet S,Quinart A,Revel P,Sztark F. A comparison of stroke volume variation measured by Vigileo/FloTrac system and aortic Doppler echocardiographyAnesth AnalgYear: 20091092466919608819
81. Belloni L,Pisano A,Natale A,et al. Assessment of fluid-responsiveness parameters for off-pump coronary artery bypass surgery: a comparison among LiDCO, transesophageal echochardiography, and pulmonary artery catheterJ Cardiothorac Vasc AnesthYear: 2008222243818375327
82. Marquez J,McCurry K,Severyn DA,et al. Ability of pulse power, esophageal Doppler, and arterial pulse pressure to estimate rapid changes in stroke volume in humansCrit Care MedYear: 2008363001300718824912
83. Gouvêa G,Diaz R,Auler L,Toledo R,Martinho JM. Evaluation of the pulse pressure variation index as a predictor of fluid responsiveness during orthotopic liver transplantationBr J AnaesthYear: 200910322384319454548
84. Diaper J,Ellenberger C,Villiger Y,Robert J,Tschopp JM,Licker M. Transoesophageal Doppler monitoring for fluid and hemodynamic treatment during lung surgeryJ Clin Monit ComputYear: 20082253677418932010
85. A Goddard NG,Menadue LT,Wakeling HG. A case for routine oesophageal Doppler fluid monitoring during major surgery becoming a standard of careBr J AnaesthYear: 2007994599
86. Benes J,Chytra I,Altmann P,et al. Intraoperative fluid optimization using stroke volume variation in high risk surgical patients: results of prospective randomized studyCrit CareYear: 2010143R11820553586
87. Walsh SR,Tang TY,Farooq N,Coveney EC,Gaunt ME. Perioperative fluid restriction reduces complications after major gastrointestinal surgerySurgeryYear: 20081434466818374042
88. Abbas SM,Hill AG. Comparison of stroke volume (SV) and stroke volume respiratory variation (SVV) measured by the axillary artery pulse-contour method and by aortic Doppler echocardiography in patients undergoing aortic surgery
89. Wenkui Y,Ning L,Jianfeng G,et al. Restricted peri-operative fluid administration adjusted by serum lactate level improved outcome after major elective surgery for gastrointestinal malignancySurgeryYear: 201014745425220004445
90. Rohde LE,Polanczyk CA,Goldman L,Cook EF,Lee RT,Lee TH. Usefulness of transthoracic echocardiography as a tool for risk stratification of patients undergoing major noncardiac surgeryAm J CardiolYear: 2001875505911230829
91. Echocardiographic evaluation of global left ventricular function during high thoracic epidural anesthesia
92. Cavallaro F,Marano C,Sandroni C,Dell'anna A. Systolic anterior motion causing hemodynamic instability and pulmonary edema during bleedingMinerva AnestesiolYear: 2010768653620661209
93. Skiles JA,Griffin BP. Transesophageal echocardiographic (TEE) evaluation of ventricular functionCardiol ClinYear: 20001846819711236160
94. Perrino AC Jr,Luther MA,O'Connor TZ,Cohen IS. Automated echocardiographic analysis. Examination of serial intraoperative measurementsAnesthesiologyYear: 1995832285927631950
95. Cevik Y,Dagertekin M,Basaran Y,Turen F,Pektas O. A new echocardiographic formula to calculate ejection fraction by using systolic excursion of mitral annulusAngiologyYear: 199546157637702201
96. Elnoamany MF,Abdelameed AK. Mitral annular motion as a surrogate for left ventricular function: correlation with brain natriuretic peptide levelsEur J EchocardiogrYear: 200671879816046188
97. Elkington T,Dobson A. Oesophageal Doppler and the ProSeal Laryngeal Mask AirwayAnaesthesiaYear: 20056082716029249
98. Kamath S,Chatterjee N,Acharya S,Singha SK. Transesophageal echocardiography induced airway obstruction in a patient in whom the trachea had been intubated via a LMA CTrachAnesth AnalgYear: 2009108135719299822

Article Categories:
  • Article

Keywords: Keywords Transesophageal echocardiography, hemodynamic monitoring, intraoperative, non-cardiac surgery..

Previous Document:  Sepsis-induced cardiomyopathy.
Next Document:  The use of echocardiography in the critically ill; the role of FADE (Fast Assessment Diagnostic Echo...