Abstract/OtherAbstract:
BACKGROUND: Although monopolar radiofrequency treatment is effective in the improvement of skin laxity, the pain and cost that are associated with this method suggest the need for alternative treatment options. Recently, an infrared device with contact cooling has been shown to be effective in the treatment of skin laxity, with ultrastructural changes observed that are similar to those that are observed following treatment with a monopolar radiofrequency device. However, no control was included in previous studies. OBJECTIVE: To conduct a prospective, split-face, single-blinded study to look at the efficacy and complications among Asians of treatment for skin tightening with an infrared device with contact cooling. METHOD: Thirteen Chinese women were treated. An infrared device with contact cooling (Titan, Cutera, Brisbane, CA) was used to treat one side of the face and the untreated side served as the control. The treatment was performed twice with a 4-week interval between the treatments and the patients were followed up by subjective assessment using a structured questionnaire 1 and 3 months after the second (and last) treatment. In all cases, pre- and post-treatment clinical photographs were taken. Two independent observers assessed the photographs. RESULTS: Twenty-three percentage of patients reported mild improvement, 15% reported moderate improvement, and 54% reported significant improvement 3 months after their second (and last) treatment. In terms of objective assessment, 41% of patients were identified to have some degree of improvement of the treated side 3 months after their second treatment. Compared with the untreated side, the treated side improved significantly (P = 0.031) at 1 and 3 months after the second treatment. Blistering occurred in one patient, which had resolved completely by the 3-month follow-up visit. CONCLUSION: An infrared device with contact cooling can be used effectively and safely for the treatment of skin laxity, especially in smaller anatomical areas.
Authors:
Henry H Chan; C S Yu; S Shek; C K Yeung; T Kono; W I Wei
Related Documents :
18349665 - Percutaneous collagen induction therapy: an alternative treatment for scars, wrinkles, ...
1298025 - Ivomec, a treatment against rabbit mange.
11490185 - The influence of hair shave on the infection rate in neurosurgery. a prospective study.
3347665 - Skin sensation after suction lipectomy: a prospective study of 50 consecutive patients.
15150185 - Treatment of complicated urinary tract infection in adults: combined analysis of two ra...
9915185 - A simple preparation of autologous fibrin glue for skin-graft fixation.
Publication Detail:
Type:  Controlled Clinical Trial; Journal Article    
Journal Detail:
Title:  Lasers in surgery and medicine     Volume:  40     ISSN:  0196-8092     ISO Abbreviation:  Lasers Surg Med     Publication Date:  2008 Feb 
Date Detail:
Created Date:  2008-03-04     Completed Date:  2008-06-03     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  8007168     Medline TA:  Lasers Surg Med     Country:  United States    
Other Details:
Languages:  eng     Pagination:  146-52     Citation Subset:  IM    
Affiliation:
Division of Dermatology, Department of Medicine, University of Hong Kong, Hong Kong SAR, China. hhlchan@hku.hk
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Aged
Asian Continental Ancestry Group*
China
Female
Follow-Up Studies
Humans
Infrared Rays / therapeutic use*
Laser Therapy / instrumentation*,  methods
Middle Aged
Prospective Studies
Single-Blind Method
Skin Aging / pathology,  radiation effects*

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Treatment of resistant tattoos using a new generation Q-switched Nd:YAG laser: influence of beam pro...
Next Document:  Selective transcutaneous delivery of energy to porcine soft tissues using Intense Ultrasound (IUS).