Document Detail


The prediction of fetal lung maturity from the surface tension characteristics of amniotic fluid.
MedLine Citation:
PMID:  1242728     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
In recent years fetal lung maturity has been assessed by chemical determination of lung surfactant components in the amniotic fluid. The variation in the results, however, limits the clinical usefulness of these methods. To establish reliable criteria for fetal lung maturity 98 specimens of amniotic fluid were obtained in the 23rd to 41st week of gestation and their surface properties measured in the surface balance (Fig 1). A continuous rise in surface activity of amniotic fluid was observed during this period (Fig. 2). In the evaluation of the surface activity of amniotic fluid y-min appears to be the most suitable parameter because it shows a considerable change during the course of pregnancy and has low variations (Fig. 3). In 64 prematures amniotic fluid was obtained during delivery and its surface properties measured. The correlation of clinical symptoms of the premature with y-min of the amniotic fluid makes it possible to predict the fetal lung maturity at a given y-min value (Fig. 4). When the results are arranged according to the incidence of RDS (lethal RDS, recovered from RDS and without RDS) three y-min-ranges can be clearly distinguished. When y-min of the amniotic fluid is over 27 dyn/cm the probability of lethal RDS is 100%, whereas when y-min is under 17 dyn/cm a mature lung can be expected. In the range between 27 to 17 dyn/cm any degree of lung maturity can be encountered. By division of this range in two additional ones a more accurate prediction of fetal lung maturity is possible: In the y-min-range 27-23 dyn/cm RDS-probability is approximately 70%, in the range 23-17 dyn/cm it is only 30% (Fig. 4). Measurements of surface activity of the amniotic fluid make it possible to predict fetal lung maturity and estimate RDS-probability.
Authors:
E Müller-Tyl; J Lempert
Related Documents :
3946508 - Amniotic fluid phosphatidylglycerol and phosphatidylcholine phosphorus as predictors of...
843488 - A critical evaluation of tests used to assess gestational age.
3024688 - Assessment of the datex relaxograph during anaesthesia and atracurium-induced neuromusc...
6623138 - Amniotic fluid phosphatidylglycerol: a predictor of fetal lung maturity using conventio...
6491068 - Left atrial isomerism associated with asplenia: prenatal echocardiographic detection of...
9541368 - Effect of lead on fetal growth in a canadian smelter city, 1961-1990.
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Journal of perinatal medicine     Volume:  3     ISSN:  0300-5577     ISO Abbreviation:  J Perinat Med     Publication Date:  1975  
Date Detail:
Created Date:  1976-02-19     Completed Date:  1976-02-19     Revised Date:  2004-11-17    
Medline Journal Info:
Nlm Unique ID:  0361031     Medline TA:  J Perinat Med     Country:  GERMANY, WEST    
Other Details:
Languages:  eng     Pagination:  47-52     Citation Subset:  IM    
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Amniotic Fluid / analysis*
Female
Fetus*
Gestational Age
Humans
Infant, Newborn
Infant, Premature
Lung / growth & development*,  physiopathology
Pregnancy
Probability
Pulmonary Surfactants / analysis*
Respiratory Distress Syndrome, Newborn / physiopathology
Surface Tension
Chemical
Reg. No./Substance:
0/Pulmonary Surfactants

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Dosimetry of several DTPA radiopharmaceuticals in cisternography.
Next Document:  Analysis of Duboisia myoporoides R. Br. and Duboisia leichhardtii F. Muell.