A portable volume/flow calibrating syringe.
MedLine Citation:
PMID:  7128227     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
Two samples of a manual 3 L calibrating syringe which displays an electronically calculated FEF25-75% were evaluated to determine its suitability as a flow calibrator were evaluated. Room air was discharged into a manual spirometer system known to be accurate. The calibrator-determined values correlated very closely with the spirometer values over an FEF25-75% range of 0.4 to 9 L/sec. The differences between calibrator and spirometer FEF25-75% values were small (mean +/- 1 percent, greatest 3.7 percent) and of little importance clinically. This portable, simple to operate calibrating syringe provides accurate FEF25-75% and volume values. By adding flow calibrating capability to a recommended standard volume calibrating syringe, it will facilitate the routine calibration of spirometers in the laboratory and in the field. Since it uses displaced air, it can be used at altitude and with flow measuring instruments without the correction required for calibrators using CO2 cartridges.
Authors:
J W Shigeoka; R M Gardner; H W Barkman
Related Documents :
17953987 - A method for assessment of blood volume parameters in pregnant sheep using fluorescein-...
1049217 - The amount of blood withdrawn for diagnostic tests in critically ill patients.
127187 - Blood volume in inbred strain balb/c, cba/j and c57bl/10 mice determined by means of 59...
8697857 - Medication nebulizer performance. effects of diluent volume, nebulizer flow, and nebuli...
17066167 - Development of a respirometric biochip for embryo assessment.
23376517 - Effect of flow velocity on phytoplankton biomass and composition in a freshwater lake.
Publication Detail:
Type:  Journal Article; Research Support, U.S. Gov't, Non-P.H.S.    
Journal Detail:
Title:  Chest     Volume:  82     ISSN:  0012-3692     ISO Abbreviation:  Chest     Publication Date:  1982 Nov 
Date Detail:
Created Date:  1982-12-16     Completed Date:  1982-12-16     Revised Date:  2006-11-15    
Medline Journal Info:
Nlm Unique ID:  0231335     Medline TA:  Chest     Country:  UNITED STATES    
Other Details:
Languages:  eng     Pagination:  598-601     Citation Subset:  AIM; IM    
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Calibration
Humans
Spirometry / instrumentation,  standards
Syringes*
Vital Capacity / instrumentation*

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Surgery of descending aorta. A method of autotransfusion and intercostal artery preservation.
Next Document:  The UCLA population studies of chronic obstructive respiratory disease. 5. Agreement and disagreemen...