A plea for consistent reliability in ambulatory blood pressure monitoring: an unusual case of software error in Spacelabs Report Management System 92506.
MedLine Citation:
PMID:  23080398     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
OBJECTIVE: Ambulatory blood pressure monitors are subject to extensive validation protocols, but no international guidelines on the software processing the collected raw data exist. Hence, there seems to be little or no control of ambulatory blood pressure monitoring (ABPM) software with respect to errors. In this paper, we wish to point out an important error in Spacelabs Report Management System 92506 software. METHODS: By chance, we noticed discrepancies in the Spacelabs Report Management System 92506 hourly average tabular as shown on-screen and on printout. To exclude the possibility of a random error, 97 ABPM reports were evaluated. In a random patient, we calculated the hourly averages by the arithmetic mean from all measurements. Similarly, the summary average of 24 h, daytime and night-time blood pressure was calculated both by the arithmetic mean of all measurements and by the mean of hourly averages in the respective periods. RESULTS: Evaluation of ABPM reports showed errors in 89 out of 97 (92%). In a random patient, the numerical difference between printout and on-screen hourly averages was considerable, ranging from -37 to 18 mmHg systolic and from -16 to 10 mmHg diastolic. Calculation on the basis of raw data established that on-screen hourly average tabular was correct, whereas printout values were erroneous. The erroneous values were also found in the exported hourly average tabular. CONCLUSION: If researchers base calculations on the use of erroneous data from printout or exported hourly average tabular, the results and hence the conclusions may be wrong. Focus on ABPM software is warranted.
Authors:
Niklas B Rossen; Klavs W Hansen
Related Documents :
6643538 - The effect of impact on the marrow pressure of long bones in vitro.
12219918 - The effect of frog pressure and downward vertical load on hoof wall weight-bearing and ...
14741308 - Temporal patterns of plantar pressures and lower-leg muscle activity during walking: ef...
11154928 - Foot pressure and radiographic outcome measures of lateral column lengthening for pes p...
17271458 - Preliminary look at why some vessels get atherosclerosis and others don't.
1352718 - Sympathoinhibitory effects of rilmenidine may be mediated by sites located below the br...
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2012-10-17
Journal Detail:
Title:  Blood pressure monitoring     Volume:  -     ISSN:  1473-5725     ISO Abbreviation:  Blood Press Monit     Publication Date:  2012 Oct 
Date Detail:
Created Date:  2012-10-19     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  9606438     Medline TA:  Blood Press Monit     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Affiliation:
Department of Medicine, Silkeborg Regional Hospital, Silkeborg, Denmark.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Cardiometabolic Risk in Adolescents: Associations with Physical Activity, Fitness, and Sleep.
Next Document:  C(2v) symmetrical two-photon polymerization initiators with anthracene core: synthesis, optical and ...