A one-kilogram quartz resonator as a mass standard.
MedLine Citation:
PMID:  23357918     Owner:  NLM     Status:  In-Data-Review    
Abstract/OtherAbstract:
The SI unit of mass, the kilogram, is defined by a single artifact, the International Prototype Kilogram. This artifact, the primary mass standard, suffers from long-term instabilities that are neither well understood nor easily monitored. A secondary mass standard consisting of a 1-kg quartz resonator in ultrahigh vacuum is proposed. The frequency stability of such a resonator is likely to be far higher than the mass stability of the primary mass standard. Moreover, the resonator would provide a link to the SI time-interval unit. When compared with a laboratory-grade atomic frequency standard or GPS time, the frequency of the resonator could be monitored, on a continuous basis, with 10(-15) precision in only a few days of averaging. It could also be coordinated, worldwide, with other resonator mass standards without the need to transport the standards.
Authors:
John Vig; David Howe
Related Documents :
25459458 - Mr imaging with t2*- mapping for improved acetabular cartilage assessment in fai-a case...
24928498 - Magnetic resonance imaging assessed cortical porosity is highly correlated with μct po...
23371908 - Effects of the use of multiple scanners and of scanner upgrade in longitudinal voxel-ba...
25341408 - Preprocedural magnetic resonance imaging for image-guided catheter ablation of scar-rel...
18218008 - Effectiveness of real-time virtual sonography-guided radiofrequency ablation treatment ...
15236408 - Mr molecular imaging of early endothelial activation in focal ischemia.
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  IEEE transactions on ultrasonics, ferroelectrics, and frequency control     Volume:  60     ISSN:  1525-8955     ISO Abbreviation:  IEEE Trans Ultrason Ferroelectr Freq Control     Publication Date:  2013 Feb 
Date Detail:
Created Date:  2013-01-29     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  9882735     Medline TA:  IEEE Trans Ultrason Ferroelectr Freq Control     Country:  United States    
Other Details:
Languages:  eng     Pagination:  428-31     Citation Subset:  IM    
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Adaptive spectral estimators for fast flow-profile detection.
Next Document:  Influence of cell line and cell cycle phase on sonoporation transfection efficiency in cervical carc...