| A novel detachable filter to prevent thromboembolism during endovascular surgery. | |
| | |
MedLine Citation:
|
PMID: 22306217 Owner: NLM Status: Publisher |
Abstract/OtherAbstract:
|
OBJECTIVE: Thromboembolism remains a serious complication during endovascular surgery. Commercially available filter devices, which are unified with the stenting systems, provide short-time performance owing to the adhesion of thrombus to the filters themselves. We have, therefore, developed a new detachable filter that can be used in all major aortic branches and shows greater longevity. The present study assessed the efficacy of the new detachable filter and examined the feasibility of deploying and retrieving the filters. METHODS: We first performed in vitro studies. Our experimental flow model used silicon tubing to simulate the aortic branches. Polystyrene-divinylbenzene microspheres (100 and 200 μm in diameter), which simulated embolic particles, were injected into the tubing after the detachable filter was deployed. The capture efficacy (number of microspheres trapped in the detachable filter/total injected microspheres) was calculated. In the in vivo studies, the detachable filters were implanted into the carotid, visceral, and renal arteries of 5 mongrel dogs. Angiography was performed every 30 minutes. At 5 hours after implantation, each detachable filter was retrieved by a gooseneck snare catheter. RESULTS: In the in vitro studies, our detachable filters showed high capture efficacy, capturing 99.2% of the 100-μm microspheres and 99.4% of the 200-μm microspheres. In the in vivo studies, all detachable filters were successfully deployed into the major branches. Each angiographic study revealed smooth flow without any embolic obstruction of the filter. At 5 hours after deployment, all devices were completely retrieved by the snare catheter without aortic injury. CONCLUSIONS: The new detachable filter showed high efficacy in capturing the particles. All detachable filters were successfully deployed for 5 hours, and the filters were retrieved from the aortic branches without any complications. This novel detachable filter can help prevent serious distal thromboembolism during endovascular surgery. |
| | |
Authors:
|
Kyokun Uehara; Akira Marui; Yoshimasa Nagata; Mitsuru Sato; Takahide Takeda; Tadashi Ikeda; Ryuzo Sakata; Kanji Inoue |
Related Documents
:
|
22614527 - Stanford type a aortic dissection with intimal intussusception. 22503547 - Evaluation of possible subclinical atherosclerosis in adolescents with a family history... 9116787 - Comparison of heparinized and nonheparinized solutions for maintaining patency of arter... 1914397 - Complications of direct brachial artery puncture for arteriography: a comparison of tec... 9804477 - Monocusp valve and transannular patch reconstruction of the right ventricular outflow t... 17652917 - Spontaneous thrombosis of a venous malformation leading to intracerebral hemorrhage--ca... |
Publication Detail:
|
Type: JOURNAL ARTICLE Date: 2012-2-3 |
Journal Detail:
|
Title: The Journal of thoracic and cardiovascular surgery Volume: - ISSN: 1097-685X ISO Abbreviation: - Publication Date: 2012 Feb |
Date Detail:
|
Created Date: 2012-2-6 Completed Date: - Revised Date: - |
Medline Journal Info:
|
Nlm Unique ID: 0376343 Medline TA: J Thorac Cardiovasc Surg Country: - |
Other Details:
|
Languages: ENG Pagination: - Citation Subset: - |
Copyright Information:
|
Copyright © 2012 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved. |
Affiliation:
|
Department of Cardiovascular Surgery, Kyoto University Graduate School of Medicine, Kyoto, Japan. |
Export Citation:
|
APA/MLA Format Download EndNote Download BibTex |
| MeSH Terms | |
Descriptor/Qualifier:
|
|
From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine
Previous Document: Perioperative atrial tachycardia is associated with increased mortality in infants undergoing cardia...