A new technique for right heart catheterization with a Swan-Ganz balloon catheter via femoral vein in the patient with dilated right heart chambers, utilizing a modified transseptal-type sheath.
MedLine Citation:
PMID:  1830829     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
Right heart catheterization with a Swan-Ganz balloon catheter via femoral vein in the patient with dilated right atrium and ventricle is frequently difficult due to excessive catheter coiling in the dilated atrium. A new technique is described in this situation. By using a modified transseptal-type sheath positioned counterclockwise in right atrium as an introducing sheath, a balloon catheter can be easily advanced to the distal pulmonary artery by smooth counterclockwise direction and secure support from this sheath.
Authors:
H H Lee; P R Mahrer
Related Documents :
22792429 - Antegrade recanalization of parent artery after internal trapping of ruptured vertebral...
15851219 - Successful release of entrapped circumferential mapping catheters in patients undergoin...
22638999 - Three-year-old child with middle aortic syndrome treated by endovascular stent implanta...
18091549 - Prospective study of peripheral arterial catheter infection and comparison with concurr...
6744409 - Ergonovine provocative testing: description of a "double catheter technique".
22889979 - Onyx embolization of high flow spontaneous cervical vertebral arteriovenous fistula.
23401729 - Asymptomatic aortic dissection late after aortic valve replacement.
19138849 - Microembolic signals in subarachnoid hemorrhage.
1334789 - Correlation between sonographic and angiographic findings of extracranial carotid arter...
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Catheterization and cardiovascular diagnosis     Volume:  23     ISSN:  0098-6569     ISO Abbreviation:  Cathet Cardiovasc Diagn     Publication Date:  1991 May 
Date Detail:
Created Date:  1991-09-06     Completed Date:  1991-09-06     Revised Date:  2004-11-17    
Medline Journal Info:
Nlm Unique ID:  7508512     Medline TA:  Cathet Cardiovasc Diagn     Country:  UNITED STATES    
Other Details:
Languages:  eng     Pagination:  54-6     Citation Subset:  IM    
Affiliation:
Section of Cardiology, Kaiser Permanente Harbor City Medical Center, CA 90710.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Cardiomegaly / pathology
Catheterization, Swan-Ganz / instrumentation*
Femoral Vein
Heart Atria
Heart Catheterization / instrumentation,  methods*
Humans
Comments/Corrections
Comment In:
Cathet Cardiovasc Diagn. 1991 Oct;24(2):151   [PMID:  1742786 ]
Cathet Cardiovasc Diagn. 1991 Dec;24(4):322   [PMID:  1756575 ]

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Proximal rupture and intracoronary entrapment of a rotating device during low-speed rotational coron...
Next Document:  Leukocyte adhesion in host defense and tissue injury.