Document Detail


A new technique for right heart catheterization with a Swan-Ganz balloon catheter via femoral vein in the patient with dilated right heart chambers, utilizing a modified transseptal-type sheath.
MedLine Citation:
PMID:  1830829     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
Right heart catheterization with a Swan-Ganz balloon catheter via femoral vein in the patient with dilated right atrium and ventricle is frequently difficult due to excessive catheter coiling in the dilated atrium. A new technique is described in this situation. By using a modified transseptal-type sheath positioned counterclockwise in right atrium as an introducing sheath, a balloon catheter can be easily advanced to the distal pulmonary artery by smooth counterclockwise direction and secure support from this sheath.
Authors:
H H Lee; P R Mahrer
Related Documents :
22675269 - Prenatal diagnosis of an aneurysm of the vein of galen by three-dimensional power and c...
22295739 - Incidence of the accessory internal thoracic artery and its safety area in the thoracic...
22306219 - Bilateral internal thoracic artery grafting is superior to other forms of multiple arte...
22737259 - Feasibility of using intravascular ultrasonography for assessment of giant cavernous an...
22293879 - Sex-specific association of anthropometric measures of body composition with arterial s...
155629 - Nonsurgical removal of intravascular foreign bodies.
21550909 - Preliminary experience with optical coherence tomography imaging to evaluate carotid ar...
23692659 - Alternative perfusion technique without axillary artery cannulation during combined aor...
24059889 - High resolution ct angiography in detection of an aneurysm of the vein of galen as a so...
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Catheterization and cardiovascular diagnosis     Volume:  23     ISSN:  0098-6569     ISO Abbreviation:  Cathet Cardiovasc Diagn     Publication Date:  1991 May 
Date Detail:
Created Date:  1991-09-06     Completed Date:  1991-09-06     Revised Date:  2004-11-17    
Medline Journal Info:
Nlm Unique ID:  7508512     Medline TA:  Cathet Cardiovasc Diagn     Country:  UNITED STATES    
Other Details:
Languages:  eng     Pagination:  54-6     Citation Subset:  IM    
Affiliation:
Section of Cardiology, Kaiser Permanente Harbor City Medical Center, CA 90710.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Cardiomegaly / pathology
Catheterization, Swan-Ganz / instrumentation*
Femoral Vein
Heart Atria
Heart Catheterization / instrumentation,  methods*
Humans
Comments/Corrections
Comment In:
Cathet Cardiovasc Diagn. 1991 Oct;24(2):151   [PMID:  1742786 ]
Cathet Cardiovasc Diagn. 1991 Dec;24(4):322   [PMID:  1756575 ]

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Proximal rupture and intracoronary entrapment of a rotating device during low-speed rotational coron...
Next Document:  Leukocyte adhesion in host defense and tissue injury.