A new pulse duplicator with a passive fill ventricle for analysis of cardiac dynamics.
MedLine Citation:
PMID:  20878198     Owner:  NLM     Status:  In-Process    
Abstract/OtherAbstract:
A new pulse duplicator was designed for evaluation of the performance of ventricular assist devices through pressure-volume (P-V) diagrams of the native heart. A linear drive system in combination with a pusher-plate mechanism was designed as a drive system to implement the passive fill mechanism during diastole of the mock ventricle. The compliances of the native heart during both diastole and systole were simulated by placing a ventricle sack made of soft latex rubber in a sealed chamber and by varying the air-to-fluid volume ratio inside the chamber. The ratio of the capacities of the systemic venous and pulmonary circuits was adjusted to properly reflect the effects of volume shift between them. As the air-to-fluid volume ratio was varied from 1:12.3 to 1:1.58, the contractility of the ventricle expressed by E (max) varied from 1.75 to 0.56 mmHg/ml with the mean V (0) of 4.58 ml closely mimicking those of native hearts (p < 0.05). Because the E (max) value of the normal human heart ranges from 1.3 to 1.6, with a value below 1.0 indicating heart failure, the mock ventricle is applicable in simulating the dynamics of the normal heart and the sick heart. The P-V diagram changes seen with rotary blood pump assistance revealed changes similar to those reported by other workers. The effects of the ventricular assist device, either pulsatile or continuous flow, on cardiac dynamics can be easily simulated with this system to derive design criteria for clinical circulatory assist devices.
Authors:
Yoshimasa Yokoyama; Osamu Kawaguchi; Tadahiko Shinshi; Ulrich Steinseifer; Setsuo Takatani
Related Documents :
12000008 - The inhibition of pro-inflammatory cytokines with pentoxifylline in the cardiopulmunary...
1653768 - Effects of three sodium-potassium adenosine triphosphatase inhibitors.
15007448 - Electrically actuated, pressure-driven microfluidic pumps.
7164228 - Control system for circulatory assist devices: determination of suitable control variab...
10675968 - Blood pressure and hormonal responses to short whole body cold exposure in subjects wit...
21885958 - Ambulatory blood pressure monitoring among patients with cerebrovascular disease.
Publication Detail:
Type:  Journal Article; Research Support, Non-U.S. Gov't     Date:  2010-09-28
Journal Detail:
Title:  Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs     Volume:  13     ISSN:  1619-0904     ISO Abbreviation:  J Artif Organs     Publication Date:  2010 Dec 
Date Detail:
Created Date:  2010-12-20     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  9815648     Medline TA:  J Artif Organs     Country:  Japan    
Other Details:
Languages:  eng     Pagination:  189-96     Citation Subset:  IM    
Affiliation:
Department of Artificial Organs, Institute of Biomaterials and Bioengineering, Tokyo Medical and Dental University, 2-3-10 Surugadai, Kanda, Chiyoda-ku, Tokyo, 101-0062, Japan.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Developmental trajectories of physical aggression: prediction of overt and covert antisocial behavio...
Next Document:  The effect of antifungal treatment on the vaginal flora of women with vulvo-vaginal yeast infection ...