BACKGROUND: Esophageal varices are a frequent source of bleeding in patients with cirrhosis. Elevated intravariceal pressure is associated with variceal bleeding. There is no simple, easy-to-use device for noninvasive measurement of intravariceal pressure. The purposes of this study were to develop a noninvasive method for measuring intravariceal pressure, and to develop a model of esophageal varices that can be used to test this pressure measurement device. METHODS: A variceal pressure measurement device was constructed by placing a 20 MHz US transducer in a latex balloon catheter sheath and attaching the catheter to a pressure transducer. The pressure measurement device was passed though the accessory channel of a large-channel endoscope and tested in blinded fashion by using tip deflection to compress each of 4 variceal models with the device. The pressure within each model was measured 10 times by 2 separate investigators blinded to the actual pressures. The mean (SD) pressure was calculated for each model. The variceal models were made of nitrocellulose dialysis tubing filled with water. Each "varix" had the same diameter but a different intraluminal pressure (5.5, 10, 15, 21.5 mm Hg). OBSERVATIONS: The correlation coefficient between the actual and measured "varix" pressures for the first investigator (L.S.M.) was r = 0.96: 99% CI [0.93, 0.98]. For the varix models with pressures of 21.5, 15, 10, and 5.5 the percent errors were, respectively, 9.5, 3.9, 5.1, and 0.7. The correlation coefficient between the actual and measured varix pressures for the second investigator (Q.D.) was r = 0.97: 99% CI [0.94, 0.98]. For the varix models with pressures of 21.5, 15, 10, and 5.5 the percent errors were, respectively, 10.3, 3.4, 9.8, and 1.1. The correlation coefficient between the 2 investigators (L.S.M., Q.D.) for the varix model pressures was r = 0.97: 99% CI [0.95, 0.99]. CONCLUSION: The variceal pressure measuring device developed for this study measured intravariceal pressure in a model varix with a low percent error and high correlation to the actual pressures. Intraobserver and interobserver variability was low. |
| | |
Authors:
|
Elan S Miller; Joseph K Kim; Jasneet Gandehok; Mak Hara; Qing Dai; Aslam Malik; Aaron Miller; Larry Miller |
Related Documents
:
|
3256414 - Postprandial haemodynamic changes: a source of bias in cardiovascular research affected... 6989344 - Positive pressure respiratory assist for wheelchair-mobile persons. 20615734 - Comparison of high definition oscillometric and doppler ultrasonic devices for measurin... 15233664 - A new ultrasound-guided esophageal variceal pressure-measuring device. 21402734 - Doppler flow spectra of the superior vena cava in a rat model of chronic pulmonary hype... 7041594 - Role of sympathetic nervous system activity in the blood pressure response to long-term... |
Publication Detail:
|
Type: Journal Article |
Journal Detail:
|
Title: Gastrointestinal endoscopy Volume: 56 ISSN: 0016-5107 ISO Abbreviation: Gastrointest. Endosc. Publication Date: 2002 Aug |
Date Detail:
|
Created Date: 2002-07-29 Completed Date: 2002-09-19 Revised Date: 2004-11-17 |
Medline Journal Info:
|
Nlm Unique ID: 0010505 Medline TA: Gastrointest Endosc Country: United States |
Other Details:
|
Languages: eng Pagination: 284-91 Citation Subset: IM |
Affiliation:
|
Temple University Hospital, Philadelphia, Pennsylvania 19140, USA. |
Export Citation:
|
APA/MLA Format Download EndNote Download BibTex |
| MeSH Terms | |
Descriptor/Qualifier:
|
Balloon Dilatation
/
instrumentation* Endosonography Esophageal and Gastric Varices / physiopathology* Esophagoscopes* Humans Models, Cardiovascular Pressure Transducers |
From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine
Previous Document: Novel magnified endoscopic findings of microvascular architecture in intramucosal gastric cancer.
Next Document: Usefulness of EUS-guided fine needle aspiration (EUS-FNA) in the diagnosis of functioning neuroendoc...