We report a home-made combustion apparatus for study of pressure-dependent laminar premixed flames with tunable vacuum ultraviolet photoionization mass spectrometry. The instrument consists of a flame chamber, a photoionization chamber with a single-stage sampling system, an ion transfer∕storage system, and an orthogonal-acceleration reflectron time-of-flight mass spectrometer. Preliminary results of fuel-rich C(2)H(4)∕O(2)∕Ar flames at pressures of 30, 150, and 760 Torr have been obtained with this instrument. Compared to previous instruments [T. A. Cool, A. McIlroy, F. Qi, P. R. Westmoreland, L. Poisson, D. S. Peterka, and M. Ahmed, Rev. Sci. Instrum. 76, 094102 (2005); F. Qi, R. Yang, B. Yang, C. Q. Huang, L. X. Wei, J. Wang, L. S. Sheng, and Y. W. Zhang, Rev. Sci. Instrum. 77, 084101 (2006)], performances of the new apparatus have higher mass resolution (∼3500 at m∕z = 40), better detection limit (<1 ppm), and broader dynamic range (better than 5 order of magnitude).
Authors:
Z Y Zhou; Y Wang; X F Tang; W H Wu; F Qi
Related Documents :
8845079 - 24-h ambulatory blood pressure in 352 normal danish subjects, related to age and gender.
2714829 - Development of a three-channel, 24-h ambulatory esophageal pressure monitor.
1653289 - Relationship between fasting plasma insulin and ambulatory blood pressure in young, non...
10226229 - Twenty-four-hour ambulatory blood pressure monitoring in the evaluation of antihyperten...
7490149 - Heritability of conventional and ambulatory blood pressures. a study in twins.
10226219 - Benefits of ambulatory blood pressure monitoring in the design of antihypertensive drug...
8315209 - Effects of anesthesia on sympathetic nerve rhythm: power spectral analysis.
23086669 - The relation between habitual sleep duration and blood pressure values in japanese male...
4064719 - Continuous, on-line, real-time measurement of cardiac output and derived cardiorespirat...
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  The Review of scientific instruments     Volume:  84     ISSN:  1089-7623     ISO Abbreviation:  Rev Sci Instrum     Publication Date:  2013 Jan 
Date Detail:
Created Date:  2013-02-07     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  0405571     Medline TA:  Rev Sci Instrum     Country:  United States    
Other Details:
Languages:  eng     Pagination:  014101     Citation Subset:  IM    
Affiliation:
National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei, Anhui 230029, People's Republic of China.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  An apparatus for concurrent measurement of thermoelectric material parameters.
Next Document:  An atomic layer deposition reactor with dose quantification for precursor adsorption and reactivity ...