Document Detail

The new ambient-pressure X-ray photoelectron spectroscopy instrument at MAX-lab.
Jump to Full Text
MedLine Citation:
PMID:  22898948     Owner:  NLM     Status:  In-Data-Review    
Abstract/OtherAbstract:
The new instrument for near-ambient-pressure X-ray photoelectron spectroscopy which has been installed at the MAX II ring of the Swedish synchrotron radiation facility MAX IV Laboratory in Lund is presented. The new instrument, which is based on a SPECS PHOIBOS 150 NAP analyser, is the first to feature the use of retractable and exchangeable high-pressure cells. This implies that clean vacuum conditions are retained in the instrument's analysis chamber and that it is possible to swiftly change between near-ambient and ultrahigh-vacuum conditions. In this way the instrument implements a direct link between ultrahigh-vacuum and in situ studies, and the entire pressure range from ultrahigh-vacuum to near-ambient conditions is available to the user. Measurements at pressures up to 10(-5) mbar are carried out in the ultrahigh-vacuum analysis chamber, while measurements at higher pressures are performed in the high-pressure cell. The installation of a mass spectrometer on the exhaust line of the reaction cell offers the users the additional dimension of simultaneous reaction data monitoring. Moreover, the chosen design approach allows the use of dedicated cells for different sample environments, rendering the Swedish ambient-pressure X-ray photoelectron spectroscopy instrument a highly versatile and flexible tool.
Authors:
Joachim Schnadt; Jan Knudsen; Jesper N Andersen; Hans Siegbahn; Annette Pietzsch; Franz Hennies; Niclas Johansson; Nils Mårtensson; Gunnar Ohrwall; Stephan Bahr; Sven Mähl; Oliver Schaff
Related Documents :
23804218 - Blood pressure evaluation using sphygmomanometry assisted by arterial pulse waveform de...
24059588 - New roles for old pathways? a circuitous relationship between reactive oxygen species a...
23211428 - Noninvasive determination of arterial elasticity and blood pressure. part i: arterial v...
23558598 - A "patient-tailored" treatment of hypertension with use of impedance cardiography: a ra...
10729858 - Effect of abdominal lipectomy on lipid profile, glucose handling and blood pressure in ...
1156038 - Observations of the role of body fluid volumes and plasma renin activity in the managem...
Publication Detail:
Type:  Journal Article     Date:  2012-08-07
Journal Detail:
Title:  Journal of synchrotron radiation     Volume:  19     ISSN:  1600-5775     ISO Abbreviation:  J Synchrotron Radiat     Publication Date:  2012 Sep 
Date Detail:
Created Date:  2012-08-17     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  9888878     Medline TA:  J Synchrotron Radiat     Country:  Denmark    
Other Details:
Languages:  eng     Pagination:  701-4     Citation Subset:  IM    
Affiliation:
Division of Synchrotron Radiation Research, Department of Physics, Lund University, Box 118, 221 00 Lund, Sweden.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine

Full Text
Journal Information
Journal ID (nlm-ta): J Synchrotron Radiat
Journal ID (iso-abbrev): J Synchrotron Radiat
Journal ID (publisher-id): J. Synchrotron Rad.
ISSN: 0909-0495
ISSN: 1600-5775
Publisher: International Union of Crystallography
Article Information
Download PDF
A full version of this article is available from Crystallography Journals Online.© Joachim Schnadt et al. 2012
open-access:
Received Day: 17 Month: 5 Year: 2012
Accepted Day: 18 Month: 7 Year: 2012
Print publication date: Day: 01 Month: 9 Year: 2012
Electronic publication date: Day: 07 Month: 8 Year: 2012
pmc-release publication date: Day: 07 Month: 8 Year: 2012
Volume: 19 Issue: Pt 5
First Page: 701 Last Page: 704
ID: 3423313
PubMed Id: 22898948
Publisher Id: ie5083
DOI: 10.1107/S0909049512032700
Coden: JSYRES
Publisher Item Identifier: S0909049512032700

The new ambient-pressure X-ray photoelectron spectroscopy instrument at MAX-lab Alternate Title:New X-ray photoelectron spectroscopy instrument at MAX-lab
Joachim Schnadta*
Jan Knudsena
Jesper N. Andersenab
Hans Siegbahnc
Annette Pietzschb
Franz Henniesb
Niclas Johanssona
Nils Mårtenssonc
Gunnar Öhrwallb
Stephan Bahrd
Sven Mähld
Oliver Schaffd
aDivision of Synchrotron Radiation Research, Department of Physics, Lund University, Box 118, 221 00 Lund, Sweden
bMAX IV Laboratory, Lund University, Box 118, 221 00 Lund, Sweden
cDepartment of Physics and Astronomy, Uppsala University, Box 516, 751 20 Uppsala, Sweden
dSPECS Surface Nano Analysis GmbH, Voltastrasse 5, 13355 Berlin, Germany
Correspondence: Correspondence e-mail: joachim.schnadt@sljus.lu.se

1.  Introduction  

Today, X-ray photoelectron spectroscopy (XPS) is one of the primary workhorses for electronic structure investigations of surfaces, vapours and liquids. The vast majority of all XPS instruments, whether home laboratory or synchrotron-based, operate under vacuum conditions, i.e. typically the sample environment pressure does not exceed 10−6 mbar. The primary rationale for operation in a vacuum is the strong inelastic electron scattering cross section in the kinetic energy range between a few and some hundreds of eV (see, for example, Schram et al., 1966; Schutten et al., 1966), which puts severe restrictions on the admissible path length of the photoelectrons through gas. However, the vacuum environment heavily limits the choice of sample; therefore, early on instruments were developed which could handle vapours by the introduction of differentially pumped gas cells into the vacuum chamber (Siegbahn et al., 1969). The first dedicated XPS instruments for liquids (Siegbahn & Siegbahn, 1973) and surfaces in a vapour atmosphere (Joyner et al., 1979) followed soon after. Since then, and until the beginning of the new century, the field of high-pressure X-ray photoelectron spectroscopy (HPXPS) [‘high’ implies pressures ‘only’ up to the mbar range, often instead called ambient-pressure X-ray photoelectron spectroscopy (APXPS)] developed continuously (Siegbahn, 1985; Littrell & Tatarchuk, 1986; Ruppender et al., 1990; Grunze et al., 1992), but slowly. It was with the advent of third-generation synchrotron radiation sources that APXPS experienced its breakthrough. These sources deliver a much higher photon flux than conventional X-ray and even second-generation synchrotron radiation sources. The high photon flux also implies a very large flux of photoelectrons, and APXPS measurements become much more feasible in spite of the large loss of photoelectron intensity owing to inelastic scattering in the ambient atmosphere. Moreover, pioneering groups at the ALS and BESSY were the first to use differentially pumped electrostatic lens systems in their electron energy analysers, which significantly increases the transmission of the high-pressure-adapted analysers (Ogletree et al., 2002, 2009; Bluhm et al., 2004). The two advances of new light sources and improved electron energy analysers have led to a strong increase in the number of publications using APXPS during the last ten years (for reviews see Salmeron & Schlögl, 2008; Knop-Gericke et al., 2009). A couple of instruments available to external users are now in use at the ALS, BESSY and the NSLS and the trend goes towards the installation of further instruments at synchrotron radiation facilities around the world, a number of which will be opened to external users in the future. In addition there exist both further home laboratory-based (e.g. by Pantförder et al., 2005) and private synchrotron-based instruments.

Here we present the new instrument for APXPS at beamline I511 on the MAX II ring, which was delivered in September 2010 to replace the previous ultrahigh-vacuum (UHV) end station for XPS and resonant inelastic X-ray scattering. The beamline (Denecke et al., 1999) is an undulator-based soft X-ray beamline delivering photons in the energy range between 50 and 1500 eV. The light is monochromated by a plane-grating monochromator, and the light is refocused by a set of Kirkpatrick–Baez (KB) optics (Kirk­patrick & Baez, 1948). The APXPS instrument is connected to the beamline via a differential pumping stage similar to that employed at beamline I3 of the MAX III ring (cf. Urpelainen et al., 2010). The efficient differential pumping stage allows measurements in gas pressures up to the 10−5 mbar range in the analysis chamber without any further instrumental measures.


2.  The APXPS end station  

In contrast to other APXPS set-ups our instrument (Fig. 1a) is capable of dual and combined ambient pressure and UHV use. This is made possible by the use of a retractable ‘high-pressure cell’ [Figs. 1(b)–1(d)], which can be docked to the front aperture of the SPECS PHOIBOS 150 NAP analyser (see http://www.specs.de/) for ambient pressure use. Only the cell is filled with gases or vapours, while the analysis chamber retains a pressure of around 10−6 mbar even when the pressure is increased to 10 mbar in the cell. After retraction of the high-pressure cell into a separate chamber, UHV conditions are achieved typically within less than an hour. For ambient-pressure operation the transferable sample is loaded into the high-pressure cell, which before gas exposure is locked off from the surrounding UHV of the analysis chamber by means of a door operated by the transfer wobblestick. The high-pressure cell carries an exchangeable nozzle which upon docking constitutes the interface towards the pre-lens stage of the analyser. As in other APXPS instruments the nozzle and further apertures in the electrostatic lens system of the analyser allow differential pumping, which brings the pressure down to 5 × 10−8 mbar or better at the multichannel plate detector and thus allows ambient-pressure use (Ogletree et al., 2002). Presently available nozzle orifices have diameters of 0.3 mm and 1 mm. For reference, with the 1 mm nozzle, at 2 mbar O2 pressure in the high-pressure cell, the pressure in the analysis chamber was measured to be  mbar, pre-lens  mbar, first pumping stage  mbar, second pumping stage  mbar, and detector  mbar.

A gas system with gas cleaning facilities supplies mixtures of presently up to three gases to the cell. The flow is regulated by separate flow controllers for each of the gases. The gas exit line of the cell, connected to a roughing pump, contains a pressure controller, and thus pressure, gas flow and gas mixture can be controlled independently. Both the gas supply and gas exit lines are connected to a quadrupole mass spectrometer (QMS) via leak valves, so that the gas composition before and after sample contact can be analysed. The sample temperature is measured with a chromel-alumel thermocouple wire pair mounted on the transferable sample holder. The thermocouple junction is in direct contact with the sample, while, with the sample in place for measurement, the other ends of the wires connect to cables to outside feedthroughs via a contact on the sample holder. Thus, the sample temperature is known to within the accuracy of the thermocouple measurement. Heating is achieved through electron bombardment of the vacuum side of the wall behind the sample seat; a water-cooling loop ensures that only the seat, and not the surrounding material, is heated.

The pressure in the cell is measured by a Pirani gauge on the exit line. As is seen from Fig. 1(e), this pressure scales linearly with the real pressure in the cell as evaluated by an absolute-pressure transducer. For pressure calibration one can also use the pressure measured in the pre-lens (Fig. 1f). This pressure, however, depends on the type of gas used as an effect of different orifice pumping speeds for different gases. The advantage of using the pre-lens pressure is that it can be used for real cell pressures down to  mbar, while the Pirani is limited to minimum pressures of around 0.1 mbar. This implies that the instrument as a whole is capable of in situ measurements over the entire pressure range from UHV to mbar, with measurements up to 10−5 mbar being performed directly in the analysis chamber and higher pressures in the high-pressure cell.

A particular feature of the chosen design concept with high-pressure cells is also that the cells can be exchanged easily. This allows for custom-made cells for different applications and chemical reactions. For example, we are in the course of developing a cell for APXPS measurements on liquids, which should go into operation later this year (Siegbahn et al., 2012). It is also conceivable to develop cells for, for example, corrosive gases, high-temperature applications, in situ electrochemical measurements, etc. Thus, the design concept opens for a highly flexible use of the APXPS instrument.


3.  Proof-of-principle measurement  

We have tested the set-up in a CO oxidation experiment over Pt(111). The data are reproduced in Fig. 2. Initially the Pt(111) single crystal was exposed to 0.15 mbar pure di-oxygen at 430 K [panel (a)]. Under these conditions the O 1s spectrum is dominated by a component at 530.0 eV binding energy assigned to atomic oxygen adsorbed on the surface (Björneholm et al., 1994) and two components at 537.4 eV and 538.5 eV both assigned to molecular oxygen in the gas phase. Subsequently, CO was mixed into the gas at a 9:1 O2:CO ratio and the same total pressure of 0.15 mbar. Panels (b)–(f) of Fig. 2 show the O 1s region for this gas mixing ratio and different sample temperatures between 450 and 535 K. The atomic oxygen component at 530.0 eV disappears as soon as CO is mixed into the gas, and instead two new components are observed at 531.0 eV and 532.6 eV, consistent with CO adsorbed in bridge and on-top sites, respectively (Björneholm et al., 1994). These O 1s fingerprints of CO persist until a sample temperature of 515 K is reached. In the O 1s spectrum measured at 535 K the two CO adsorbate-induced components are absent, and instead the atomic oxygen component at 530.0 eV reappears together with a new component at 535.6 eV, which is due to CO2 in the gas phase.

The evolution of the chemical reaction was also followed using the mass spectrometer mounted at the outlet of the high-pressure cell (Fig. 2g). Clearly, CO2 production is low at temperatures below 515 K; adsorbed CO completely covers the surface and limits the surface’s reactivity. Still, there is a steady increase of the CO2 signal and a corresponding decrease in CO signal. This low-temperature activity is in line with the previously reported onset temperature for CO oxidation over Pt(111) of 305 K (Burnett et al., 2004). Moreover, low-temperature reactivity over surface steps is further enhanced at the oxygen pressures used here (Lewis et al., 2005), which might further contribute to the measured catalytic activity below 515 K.

The large change of the CO2 and CO, and indeed also O2, mass spectrometer signals at 535 K shows that the production of CO2 is increased dramatically at this sample temperature. This is the same temperature at which the CO-related peak in the O 1s spectrum disappears and is replaced by a peak due to chemisorbed oxygen. Thus, although the reaction proceeds in a Langmuir–Hinshelwood mechanism (Ertl, 1994), no adsorbed CO is visible anymore in the O 1s spectrum (Fig. 2f). The reactivity is so high that the average CO coverage is too low to be observed; only the atomic oxygen coverage is seen for this highly active phase.


4.  Summary and conclusions  

This example shows that the new set-up can be used for performing APXPS experiments and, moreover, that it is possible to correlate the XPS results to mass spectra data provided by the mass spectrometer which is connected to the exit of the high-pressure cell. Hence, the instrument does not only allow XPS measurements on the same sample under UHV and near-ambient-pressure conditions, it also offers the user the additional dimension of simultaneous reaction data monitoring.

At present, the focus of the beamline is not optimised for our set-up. Indeed, the light spot is around 2–3 mm in diameter, which compares unfavourably with the focus size of the analyser, which for the 0.3 mm aperture is around 0.2 mm × 0.2 mm. A new beamline, the SPECIES beamline, has received funding, which features an elliptically polarising undulator, a collimated plane-grating monochromator, and optimised refocusing optics with a spot size of 0.1 mm. The SPECIES beamline will further improve the opportunities for APXPS experiments at the MAX IV Laboratory in the near future.


We are grateful to the Knut and Alice Wallenberg Foundation, which has funded the instrument described here. The authors would also like to acknowledge funding from Vetenskapsrådet (grant No. 2004-4404) and the Danish Council for Independent Research. Assistance by MAX IV Laboratory staff is gratefully acknowledged.


References
Björneholm, O., Nilsson, A., Tillborg, H., Bennich, P., Sandell, A., Hernns, B., Puglia, C. & Mårtensson, N. (1994). Surf. Sci.315, L983–L989.
Bluhm, H., Hävecker, M., Knop-Gericke, A., Kleimenov, E., Schlögl, R., Teschner, D., Bukhtiyarov, V. I., Ogletree, D. F. & Salmeron, M. (2004). J. Phys. Chem. B, 108, 14340–14347.
Burnett, D. J., Capitano, A. T., Gabelnick, A. M., Marsh, A. L., Fischer, D. A. & Gland, J. L. (2004). Surf. Sci.564, 29–37.
Denecke, R., Väterlein, R., Bässler, M., Wassdahl, N., Butorin, S., Nilsson, A., Rubensson, J. E., Nordgren, J., Mårtensson, N. & Nyholm, R. (1999). J. Electron Spectrosc. Relat. Phenom.101103, 971–977.
Ertl, G. (1994). Surf. Sci.299300, 742–754.
Grunze, M., Dwyer, D. J., Nassir, M. & Tasi, Y. (1992). ACS Symp. Ser.482, 169–182.
Joyner, R. W., Roberts, M. W. & Yates, K. (1979). Surf. Sci.87, 501–509.
Kirkpatrick, P. & Baez, A. V. (1948). J. Opt. Soc. Am.38, 766–774.
Knop-Gericke, A., Kleimenov, E., Hävecker, M., Blume, R., Teschner, D., Zafeiratos, S., Schlögl, R., Bukhtiyarov, V. I., Kaichev, V. V., Prosvirin, I. P., Nizovskii, A. I., Bluhm, H., Barinov, A., Dudin, P. & Kiskinova, M. (2009). Adv. Catal.52, 213–272.
Lewis, H. D., Burnett, D. J., Gabelnick, A. M., Fischer, D. A. & Gland, J. L. (2005). J. Phys. Chem. B, 109, 21847–21857.
Littrell, D. M. & Tatarchuk, B. J. (1986). J. Vac. Sci. Technol.4, 1608–1612.
Ogletree, D. F., Bluhm, H., Hebenstreit, E. D. & Salmeron, M. (2009). Nucl. Instrum. Methods Phys. Res. A, 601, 151–160.
Ogletree, D. F., Bluhm, H., Lebedev, G., Fadley, C. S., Hussain, Z. & Salmeron, M. (2002). Rev. Sci. Instrum.73, 3872–3877.
Pantförder, J., Pöllmann, S., Zhu, J. F., Borgmann, D., Denecke, R. & Steinrück, H.-P. (2005). Rev. Sci. Instrum.76, 014102.
Ruppender, H. J., Grunze, M., Kong, C. W. & Wilmers, M. (1990). Surf. Interface Anal.15, 245–253.
Salmeron, M. & Schlögl, R. (2008). Surf. Sci. Rep.63, 169–199.
Schram, B. L., Moustafa, H. R., Schutten, J. & de Heer, F. J. (1966). Physica, 32, 734–740.
Schutten, J., de Heer, F. J., Moustafa, H. R., Boerboom, A. J. H. & Kistemaker, J. (1966). J. Chem. Phys.44, 3924–3928.
Siegbahn, H. (1985). J. Phys. Chem.89, 897–909.
Siegbahn, S., Nordling, C., Johansson, G., Hedman, J., Heden, P. F., Hamrin, K., Gelius, U., Bergmark, T., Werme, L. O., Manne, R. & Baer, Y. (1969). ESCA Applied to Free Molecules. Amsterdam: North-Holland.
Siegbahn, H., Schnadt, J., Andersén, W., Maripuu, R. & Knudsen, J. (2012). Cell. In preparation.
Siegbahn, H. & Siegbahn, K. (1973). J. Electron Spectrosc. Relat. Phenom.2, 319–325.
Urpelainen, S., Huttula, M., Balasubramanian, T., Sankari, R., Kovala, P., Kukk, E., Nõmmiste, E., Aksela, S., Nyholm, R. & Aksela, H. (2010). AIP Conf. Proc.1234, 411–414.

Article Categories:
  • Research Papers

Keywords: ambient-pressure X-ray photoelectron spectroscopy, high-pressure X-ray photoelectron spectroscopy, X-ray photoelectron spectroscopy, in situ, operando, catalysis.

Previous Document:  Structure determination of Pt-coated Au dumbbells via fluctuation X-ray scattering.
Next Document:  Zone-doubled Fresnel zone plates for high-resolution hard X-ray full-field transmission microscopy.