Document Detail


A new BOD estimation method employing a double-mediator system by ferricyanide and menadione using the eukaryote Saccharomyces cerevisiae.
MedLine Citation:
PMID:  19071604     Owner:  NLM     Status:  In-Data-Review    
Abstract/OtherAbstract:
A new biochemical oxygen demand (BOD) sensing method employing a double-mediator (DM) system coupled with ferricyanide and a lipophilic mediator, menadione and the eukaryote Saccharomyces cerevisiae has been developed. In this study, a stirred micro-batch-type microbial sensor with a 560muL volume and a two-electrode system was used. The chronamperometric response of this sensor had a linear response between 1muM and 10mM hexacyanoferrate(II) (r(2)=0.9995, 14 points, n=3, average of relative standard deviation and R.S.D.(av)=1.3%). Next, the optimum conditions for BOD estimation by the DM system (BOD(DM)) were investigated and the findings revealed that the concentration of ethanol, used to dissolve menadione, influenced the sensor response and a relationship between the sensor output and glucose glutamic acid concentration was obtained over a range of 6.6-220mgO(2)L(-1) (five points, n=3, R.S.D.(av) 6.6%) when using a reaction mixture incubated for 15min. Subsequently, the characterization of this sensor was studied. The sensor responses to 14 pure organic substances were compared with the conventional BOD(5) method and other biosensor methods. Similar results with the BOD biosensor system using Trichosporon cutaneum were obtained. In addition, the influence of chloride ion, artificial seawater and heavy metal ions on the sensor response was investigated. A slight influence of 20.0gL(-1) chloride ion and artificial seawater (18.4gL(-1) Cl(-)) was observed. Thus, the possibility of BOD determination for seawater was suggested in this study. In addition, no influence of the heavy metal ions (1.0mgL(-1) Fe(3+), Cu(2+), Mn(2+), Cr(3+) and Zn(2+)) was observed. Real sample measurements using both river water and seawater were performed and compared with those obtained from the BOD(5) method. Finally, stable responses were obtained for 14 days when the yeast suspension was stored at 4 degrees C (response reduction, 93%; R.S.D. for 6 testing days, 9.1%).
Authors:
Hideaki Nakamura; Kyota Suzuki; Hiroaki Ishikuro; Shintaro Kinoshita; Rui Koizumi; Seisaku Okuma; Masao Gotoh; Isao Karube
Related Documents :
22589794 - Cis-tetra-aqua-bis-{5-[4-(1h-imidazol-1-yl-κn(3))phen-yl]tetra-zolido}manganese(ii) di...
10751204 - Stimulation by iodide of h(2)o(2) generation in thyroid slices from several species.
22389114 - Atropoisomeric (p,n) ligands for the highly enantioselective pd-catalyzed intramolecula...
8927044 - Peroxo heteroligand vanadates(v): synthesis, spectra-structure relationships, and stabi...
3702854 - A theoretical study of the binding of phenothiazine derivatives to residues 82-93 of ca...
10951324 - Peptides containing the sulfonamide junction. 2. structure and conformation of z-tau-pr...
Publication Detail:
Type:  Journal Article     Date:  2006-11-13
Journal Detail:
Title:  Talanta     Volume:  72     ISSN:  1873-3573     ISO Abbreviation:  Talanta     Publication Date:  2007 Apr 
Date Detail:
Created Date:  2008-12-16     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  2984816R     Medline TA:  Talanta     Country:  England    
Other Details:
Languages:  eng     Pagination:  210-6     Citation Subset:  -    
Affiliation:
School of Bionics, Tokyo University of Technology, 1404-1 Katakura, Hachioji, Tokyo 192-0982, Japan; Research Center of Advanced Bionics (RCAB), National Institute of Advanced Industrial Science and Technology (AIST), Tokyo University of Technology, 1404-1 Katakura, Hachioji, Tokyo 192-0982, Japan.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Determination of atenolol at a graphite-polyurethane composite electrode.
Next Document:  A consensus least squares support vector regression (LS-SVR) for analysis of near-infrared spectra o...