Document Detail


A model-constrained Monte Carlo method for blind arterial input function estimation in dynamic contrast-enhanced MRI: II. In vivo results.
MedLine Citation:
PMID:  20679695     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
Accurate quantification of pharmacokinetic model parameters in tracer kinetic imaging experiments requires correspondingly accurate determination of the arterial input function (AIF). Despite significant effort expended on methods of directly measuring patient-specific AIFs in modalities as diverse as dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI), dynamic positron emission tomography (PET), and perfusion computed tomography (CT), fundamental and technical difficulties have made consistent and reliable achievement of that goal elusive. Here, we validate a new algorithm for AIF determination, the Monte Carlo blind estimation (MCBE) method (which is described in detail and characterized by extensive simulations in a companion paper), by comparing AIFs measured in DCE-MRI studies of eight brain tumor patients with results of blind estimation. Blind AIFs calculated with the MCBE method using a pool of concentration-time curves from a region of normal brain tissue were found to be quite similar to the measured AIFs, with statistically significant decreases in fit residuals observed in six of eight patients. Biases between the blind and measured pharmacokinetic parameters were the dominant source of error. Averaged over all eight patients, the mean biases were +7% in K(trans), 0% in k(ep), -11% in v(p) and +10% in v(e). Corresponding uncertainties (median absolute deviation from the best fit line) were 0.0043 min(-1) in K(trans), 0.0491 min(-1) in k(ep), 0.29% in v(p) and 0.45% in v(e). The use of a published population-averaged AIF resulted in larger mean biases in three of the four parameters (-23% in K(trans), -22% in k(ep), -63% in v(p)), with the bias in v(e) unchanged, and led to larger uncertainties in all four parameters (0.0083 min(-1) in K(trans), 0.1038 min(-1) in k(ep), 0.31% in v(p) and 0.95% in v(e)). When blind AIFs were calculated from a region of tumor tissue, statistically significant decreases in fit residuals were observed in all eight patients despite larger deviations of these blind AIFs from the measured AIFs. The observed decrease in root-mean-square fit residuals between the normal brain and tumor tissue blind AIFs suggests that the local blood supply in tumors is measurably different from that in normal brain tissue and that the proposed method is able to discriminate between the two. We have shown the feasibility of applying the MCBE algorithm to DCE-MRI data acquired in brain, finding generally good agreement with measured AIFs and decreased biases and uncertainties relative to the use of a population-averaged AIF. These results demonstrate that the MCBE algorithm is a useful alternative to direct AIF measurement in cases where acquisition of high-quality arterial input function data is difficult or impossible.
Authors:
Matthias C Schabel; Edward V R DiBella; Randy L Jensen; Karen L Salzman
Related Documents :
23648805 - Evaluating the impact of database heterogeneity on observational study results.
24197965 - Modelling remediation scenarios in historical mining catchments.
23181935 - Towards a practical o(nlogn) phylogeny algorithm.
16978665 - Estimation of contrast agent concentration in intra- and extra-vascular spaces of brain...
21247905 - A functional-structural model of rice linking quantitative genetic information with mor...
23505645 - Biogeographic and species richness patterns of gastropoda on the southwestern atlantic.
Publication Detail:
Type:  Journal Article; Research Support, N.I.H., Extramural; Research Support, Non-U.S. Gov't     Date:  2010-08-03
Journal Detail:
Title:  Physics in medicine and biology     Volume:  55     ISSN:  1361-6560     ISO Abbreviation:  Phys Med Biol     Publication Date:  2010 Aug 
Date Detail:
Created Date:  2010-08-03     Completed Date:  2010-11-16     Revised Date:  2013-03-28    
Medline Journal Info:
Nlm Unique ID:  0401220     Medline TA:  Phys Med Biol     Country:  England    
Other Details:
Languages:  eng     Pagination:  4807-23     Citation Subset:  IM    
Affiliation:
Utah Center for Advanced Imaging Research, Department of Radiology, University of Utah Health Sciences Center, 729 Arapeen Drive, Salt Lake City, UT 84108-1218, USA. matthias.schabel@hsc.utah.edu
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Algorithms
Arteries / pathology*
Brain / blood supply*,  pathology
Brain Neoplasms / pathology
Computer Simulation
Contrast Media / pharmacology
Humans
Magnetic Resonance Imaging / methods*
Models, Statistical
Monte Carlo Method*
Reproducibility of Results
Time Factors
Grant Support
ID/Acronym/Agency:
EB005077/EB/NIBIB NIH HHS; R01 EB000177/EB/NIBIB NIH HHS; R01 EB000177/EB/NIBIB NIH HHS
Chemical
Reg. No./Substance:
0/Contrast Media
Comments/Corrections

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Noise measurement from magnitude MRI using local estimates of variance and skewness.
Next Document:  Treatment plan adaptation for MRI-guided radiotherapy using solely MRI data: a CT-based simulation s...