| The level of accuracy and agreement in measures of FEO2, FECO2 and VE between the Cosmed K4b2 portable, respiratory gas analysis system and a metabolic cart. | |
| | |
MedLine Citation:
|
PMID: 11702919 Owner: NLM Status: MEDLINE |
Abstract/OtherAbstract:
|
This study aimed to assess the accuracy of the Cosmed K4b2 (Cosmed, Italy) portable metabolic system that measures FEO2, FECO2 and VE on a breath by breath basis. For gas concentration comparisons, expired air from 20 subjects performing treadmill running was collected in a 600 litre chain compensated Collins Tissot tank and analysed for FEO2 and FECO2 using a laboratory metabolic cart and the Cosmed K4 b2 metabolic system. For ventilation comparisons, serial steady state VE (STPD) values were measured on 10 subjects using the Cosmed K4b2 ventilation turbine and a Morgan ventilation monitor during a continuous treadmill running protocol at ascending speeds of 8, 11 and 14 km x h(-1). The Cosmed K4b2 FEO2 and FECO2 measures were significantly lower (P < 0.001) than the metabolic cart values. Pearson correlation coefficients (r) and the standard error of measurement (SEM) demonstrated a high association between the Cosmed and the metabolic cart measures (FEO2 r =0 .971, SEM 0.071: FECO2 r = 0.925, SEM 0.087). Cosmed VE (l x min(-1)) measures were significantly greater than Morgan values at running speeds of 8 kmh(-1) (P < 0.001) and 11 kmh(-1) (P < 0.001) but not significantly different at 14 km x h(-1) (P > 0.05). When VE measures at the three running speeds were combined, the mean difference between instrument measures ranged between 3.5 - 4.0 l x min(-1) but the values were highly correlated (r= 0.982, P<0.01; SEM 3.03). Linear regression analysis revealed the following regression equations to predict metabolic cart values from Cosmed measures: FEO2 = 0.852+0.963 Cosmed (R2 = 0.940, P<0.00 1), FECO2 = 0.627+0.878 Cosmed (R2=0.856, P<0.001), VE = -2.50+0.984 Cosmed (R2 = 0.965. P < 0.001). The results indicated that the Cosmed K4b2 unit assessed here produced measures of FEO2, FECO2 and VE that had strong correlation to values obtained from a metabolic cart. However, linear regression analysis may further improve the accuracy of Cosmed K4b2 measures when compared to metabolic cart values. |
| | |
Authors:
|
H C Pinnington; P Wong; J Tay; D Green; B Dawson |
Related Documents
:
|
11395819 - Is laparoscopic appendectomy safe in pregnant women? 1404579 - Longitudinal evaluation of uterine myoma growth during pregnancy. a sonographic study. 12601839 - In-utero development of the fetal colon and rectum: sonographic evaluation. 439089 - Reliability factors of delivery due dates. 17497529 - Balloon-based in vitro mdi aerosol deposition experiments on the effects of mouthpiece ... 16308899 - Analysis of z-score distribution for the quality control of fetal ultrasound measuremen... 9874289 - Changes in the weight of the thymus after birth and in pregnancy in mice. 10739529 - Fetal exposure to an intra-amniotic inflammation and the development of cerebral palsy ... 17765669 - Prediction and perinatal outcomes of fetal growth restriction. |
Publication Detail:
|
Type: Comparative Study; Evaluation Studies; Journal Article |
Journal Detail:
|
Title: Journal of science and medicine in sport / Sports Medicine Australia Volume: 4 ISSN: 1440-2440 ISO Abbreviation: J Sci Med Sport Publication Date: 2001 Sep |
Date Detail:
|
Created Date: 2001-11-12 Completed Date: 2002-02-26 Revised Date: 2006-11-15 |
Medline Journal Info:
|
Nlm Unique ID: 9812598 Medline TA: J Sci Med Sport Country: Australia |
Other Details:
|
Languages: eng Pagination: 324-35 Citation Subset: IM |
Affiliation:
|
Department of Human Movement and Exercise Science, The University of Western Australia. |
Export Citation:
|
APA/MLA Format Download EndNote Download BibTex |
| MeSH Terms | |
Descriptor/Qualifier:
|
Adolescent Adult Carbon Dioxide / analysis* Exercise / physiology Female Humans Male Oxygen / analysis* Pulmonary Ventilation* Reproducibility of Results Respiratory Function Tests / instrumentation*, standards* Sensitivity and Specificity |
| Chemical | |
Reg. No./Substance:
|
124-38-9/Carbon Dioxide; 7782-44-7/Oxygen |