The internal ventricular venting loop catheter. A new, simplified, single cannulation approach for a ventricular assist system.
MedLine Citation:
PMID:  8003756     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
The internal ventricular venting loop (IVVL) catheter is a coaxial, two lumen, bidirectional flow cannula introduced peripherally and advanced intraluminally to the pulmonary artery by its flow directed, balloon tipped inner tubing in a right ventricular assist system (RVAS), or to the left ventricle over a guide wire under fluoroscopy in a left ventricular assist system (LVAS). Its use was successfully tested in six acute canine experiments using a small IVVL catheter. Hemodynamic responses to increasing roller pump flow rates, to a maximum of 1 L/min, were initially measured. Then, hemodynamic changes to 600 ml/min, after left anterior descending artery ligation (in IVVL-LVAS) and 300 ml/min after right coronary artery ligation (in IVVL-RVAS) were regularly recorded every 15 min until cardiac arrest. The IVVL-LVAS was able to significantly decrease the pulmonary capillary wedge pressure, while the IVVL-RVAS was able to significantly decrease the central venous pressure. The IVVL system was able to partially unload the ventricles and restore about 33-60% of the cardiac output. However, it could not effectively support the heart during arrest. Thus, the IVVL catheter can facilitate simple and effective single cannulation for either RVAS or LVAS. This approach may enable ordinary cardiac centers to make use of already available blood pumps for temporary, inexpensive, and less invasive application of partially assisted circulation when intra aortic balloon pump assistance fails.
Authors:
W C Orejola; F Zhou; L Ying-Long; S Briseno; H A Mekhjian; D Bregman
Related Documents :
11899176 - Right ventricular dysfunction and organ failure in left ventricular assist device recip...
9080176 - Novacor lvad bridge to transplantation in peripartum cardiomyopathy.
312706 - Temporary left ventricular bypass: factors affecting patient survival.
12406156 - Nonlinear controller for ventricular assist devices.
6840136 - Negative lung thallium-201 uptake in right ventricular infarction.
1451546 - Electrophysiologic follow-up in dogs receiving intracoronary ethyl alcohol injection.
Publication Detail:
Type:  Journal Article; Research Support, Non-U.S. Gov't    
Journal Detail:
Title:  ASAIO journal (American Society for Artificial Internal Organs : 1992)     Volume:  40     ISSN:  1058-2916     ISO Abbreviation:  ASAIO J.     Publication Date:    1994 Apr-Jun
Date Detail:
Created Date:  1994-07-18     Completed Date:  1994-07-18     Revised Date:  2007-11-15    
Medline Journal Info:
Nlm Unique ID:  9204109     Medline TA:  ASAIO J     Country:  UNITED STATES    
Other Details:
Languages:  eng     Pagination:  181-5     Citation Subset:  IM    
Affiliation:
Department of Surgery, St. Joseph's Hospital and Medical Center, Paterson, NJ 07503.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Animals
Biocompatible Materials
Dogs
Equipment Design
Heart Catheterization / instrumentation*
Heart-Assist Devices*
Hemodynamics / physiology
Male
Polyurethanes
Pulsatile Flow
Silicone Elastomers
Chemical
Reg. No./Substance:
0/Biocompatible Materials; 0/Polyurethanes; 0/Silicone Elastomers

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Prosthetic valve endocarditis. An analysis of the outcome in 32 cases.
Next Document:  Uptake of 3H-7-cholesterol along the arterial wall at an area of stenosis.