Document Detail


An in vivo evaluation of a novel spiral cut flexible ureteral stent.
MedLine Citation:
PMID:  22386429     Owner:  NLM     Status:  In-Data-Review    
Abstract/OtherAbstract:
OBJECTIVE: The flow characteristics, ureteral conformance, and histopathologic changes of a novel spiral cut flexible ureteral stent (Percuflex Helical, Boston Scientific, Boston, MA) were evaluated in vivo in an acute and chronic porcine model.
MATERIALS AND METHODS: Flow characteristics and ureteral conformance of the novel stent were determined in 6 acute and 6 chronic swine models and compared with a control ureteral stent (Percuflex Plus, Boston Scientific). The flow characteristics were determined in vivo after ligating the renal vessels and via a nephrostomy tube delivering a standard rate of 0.9% saline at 35 cm H(2)O. Flows in the unobstructed ureter, normal stent, intraluminally obstructed stent, extraluminal obstructed stent, and both intraluminally and extraluminally obstructed conditions were determined. In the chronic animals, flow was determined at day 10, with the stent in place and immediately after stent removal. Conformance and hydronephrosis was assessed on pyelograms. Histopathologic changes were also evaluated in the chronic animals.
RESULTS: The acute and chronic flow characteristics in the novel stent were equivalent to the control stent. Size and weight of the kidney, degree of hydronephrosis, stent migration, and presence of urinary tract infection were also similar between the test and control stents. There were no differences seen in histopathologic grading or degree of encrustation in either stent. The novel stent appeared to conform better to the shape of the ureter in both acute and chronic animals.
CONCLUSION: The novel helical stent appears to drain as well as a standard stent and causes no increased degree of histopathologic changes in the ureter.
Authors:
Phillip Mucksavage; Donald Pick; Dana Haydel; Mohammed Etafy; David C Kerbl; Jason Y Lee; Cervando Ortiz-Vanderdys; Fatma Saleh; Stephania Olamendi; Michael K Louie; Elspeth M McDougall
Related Documents :
7327339 - Progression of aortic root dissection and cardiac tamponade. documented by sequential e...
2687719 - Spontaneous dissection of both extracranial internal carotid arteries.
8362439 - Intracerebral hemorrhage caused by transmural dissection of the anterior cerebral artery.
18434179 - Ascending aortic curvature as an independent risk factor for type a dissection, and asc...
19949589 - A case of coronary artery dissection after aortic replacement in acute type a aortic di...
6727509 - Intraoral ligation of the maxillary artery for posterior epistaxis.
18599269 - Optimal 3d reconstruction of coronary arteries for 3d clinical assessment.
24928069 - An uncommon presentation of eosinophilic granulomatosis with polyangiitis: a case report.
7567669 - Modified fontan procedure for left atrial isomerism: alternative technique.
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Urology     Volume:  79     ISSN:  1527-9995     ISO Abbreviation:  Urology     Publication Date:  2012 Mar 
Date Detail:
Created Date:  2012-03-05     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  0366151     Medline TA:  Urology     Country:  United States    
Other Details:
Languages:  eng     Pagination:  733-7     Citation Subset:  IM    
Copyright Information:
Copyright © 2012 Elsevier Inc. All rights reserved.
Affiliation:
Department of Urology, University of California, Irvine, Orange, California.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Laparoscopic repair of inguinal cystocele using cystoscopic light test.
Next Document:  Magnetic compression ostomy as new cystostomy technique in the rat: magnacystostomy.