The in vitro and in vivo ultrasonographic appearances of the angio-seal percutaneous closure device.
MedLine Citation:
PMID:  12413919     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
PURPOSE: To assess the ultrasound appearances of the Angio-Seal device in an animal model and in twenty patients following catheterization of the femoral artery. MATERIALS AND METHODS: Ten patients were scanned within 8 hours of their procedure (early group) and 10 at two to four days (delayed group) using Acuson Aspen and Sequoia scanners. Colour flow images were taken and Doppler spectral analysis was performed proximal proximal to, at and distal to the Angio-Seal device. Early and delayed in vitro images were taken in a water bath in which the Angio-Seal device was deployed across a normal porcine aorta for comparison. RESULT: In the ten early patients colour and Doppler drop out were seen in 100 percent and 90 percent respectively compared with 90 percent and 60 percent in the delayed group. The device was seen in 30 percent and 90 percent in early and delayed groups respectively. In the in vitro study the components of the device were seen and a posterior acustic shadow noted. This shadow was less obvious and the polymer anchor more easily seen in the delayed group. CONCLUSION: The Angio-Seal device produces a consistent artifact when scanned soon after deployment. These appearances could potentially be mistaken for a vascular occlusion by the unwary in the appropriate clinical setting of acute post catheterisation lower limb ischaemia however an awareness of the normal sonographic appearances of this device would make this misinterpretation unlikely.
Authors:
R A Corkill; P M Hughes; J C C Elford; C A Roobottom
Related Documents :
11934099 - Observation on the integrity of the blood-brain barrier after microbubble destruction b...
21879979 - Comparison of cross-sectional anatomy and computed tomography of the tarsus in horses.
19323809 - Ultrasound in evaluation of post-interventional femoral vein obstruction: a case report.
8671479 - Comparison between hysterosalpingo-contrast sonography and sonographically controlled s...
18330869 - Learning curve for doppler assessment of ductus venosus flow at 11 + 0 to 13 + 6 weeks'...
8836509 - A case of large neonatal arteriovenous malformation with heart failure. color doppler s...
15181969 - Isolated oculomotor nerve palsy due to head injury.
19298289 - Assessment of the blood supply to the lingual surface of the mandible for reduction of ...
8960729 - Accumulation of hypointense lesions ("black holes") on t1 spin-echo mri correlates with...
Publication Detail:
Type:  In Vitro; Journal Article    
Journal Detail:
Title:  Clinical radiology     Volume:  57     ISSN:  0009-9260     ISO Abbreviation:  Clin Radiol     Publication Date:  2002 Oct 
Date Detail:
Created Date:  2002-11-04     Completed Date:  2002-12-16     Revised Date:  2006-11-15    
Medline Journal Info:
Nlm Unique ID:  1306016     Medline TA:  Clin Radiol     Country:  England    
Other Details:
Languages:  eng     Pagination:  930-6     Citation Subset:  IM    
Affiliation:
The Department of Radiology, Derriford Hospital, Plymouth, Devon PL6 8DH, UK.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Absorbable Implants
Angiography / adverse effects
Angioplasty, Transluminal, Percutaneous Coronary
Animals
Artifacts*
Collagen / therapeutic use*
Femoral Artery / surgery
Hemostasis, Surgical / instrumentation*
Humans
Models, Animal
Regional Blood Flow
Swine
Ultrasonography, Doppler, Duplex / methods*
Chemical
Reg. No./Substance:
9007-34-5/Collagen

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Magnetic resonance imaging appearances of the uterus following microwave endometrial ablation.
Next Document:  The use of carbon suspension as an adjunct to wire localisation of impalpable breast lesions.