Document Detail


The finite element analysis of stresses in atherosclerotic arteries during balloon angioplasty.
MedLine Citation:
PMID:  10999364     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
Finite element models of diseased arteries subject to balloon dilation are used to study the stresses in the arterial wall and plaque at peak balloon pressures. These models incorporate large strain, simulate contact between the balloon and the inner artery, and the constituent materials are modeled as nonlinear elastic. In these analyses, balloon dilation pressures range from 300 to 450 kPa. The stress in the diseased artery is recorded under different stenosis levels dilated using different balloons and possible causes of restenosis and plaque rupture are discussed.
Authors:
V Gourisankaran; M G Sharma
Related Documents :
2772214 - Shear stress in the performance of esophageal dilation: comparison of balloon dilation ...
9133514 - Improved procedural results of coronary angioplasty with intravascular ultrasound-guide...
3158324 - Percutaneous balloon pulmonary valvuloplasty.
3654024 - Continuous wave doppler assessment of patients subjected to pulmonary balloon valvoplasty.
6419564 - Progressive thrombosis of brain arteriovenous malformations after embolization with iso...
18006164 - Sildenafil therapy in complex pulmonary atresia with pulmonary arterial hypertension.
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Critical reviews in biomedical engineering     Volume:  28     ISSN:  0278-940X     ISO Abbreviation:  Crit Rev Biomed Eng     Publication Date:  2000  
Date Detail:
Created Date:  2001-02-08     Completed Date:  2001-02-08     Revised Date:  2004-11-17    
Medline Journal Info:
Nlm Unique ID:  8208627     Medline TA:  Crit Rev Biomed Eng     Country:  UNITED STATES    
Other Details:
Languages:  eng     Pagination:  47-51     Citation Subset:  IM    
Affiliation:
Department of Engineering Science and Mechanics, The Pennsylvania State University, University Park 16802, USA. vijayg@aol.com
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Angioplasty, Balloon*
Arteries / pathology,  physiology*
Arteriosclerosis / pathology,  surgery*
Finite Element Analysis*
Humans
Nonlinear Dynamics
Recurrence
Stress, Mechanical*

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine