Document Detail


An experimental study of the interface pressure profile during level walking of a new suspension system for lower limb amputees.
MedLine Citation:
PMID:  23157843     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
BACKGROUND: Different suspension systems that are used within prosthetic devices may alter the distribution of pressure inside the prosthetic socket in lower limb amputees. This study aimed to compare the interface pressure of a new magnetic suspension system with the pin/lock and Seal-In suspension systems. METHODS: Twelve unilateral transtibial amputees participated in the study. The subjects walked on a level walkway at a self-selected speed. The resultant peak pressure with the three different suspension systems was recorded using F-socket transducers. FINDINGS: There were significant statistical differences between the three studied suspension systems. Pair-wise analyses revealed that the mean peak pressure (kPa) was lower with the magnetic system than it was with the pin/lock system over the anterior and posterior aspects during one gait cycle (89.89 vs. 79.26 and 47.22 vs. 26.01, respectively). Overall, the average peak pressure values were higher with the Seal-In system than they were with the new magnetic lock and pin/lock system. INTERPRETATION: The new magnetic system might reduce the pressure within the prosthetic socket in comparison to the pin/lock and Seal-In system during one gait cycle. This is particularly important during the swing phase of gait and may reduce the pain and discomfort at the distal residual limb in comparison to the pin/lock system.
Authors:
Arezoo Eshraghi; Noor Azuan Abu Osman; Hossein Gholizadeh; Sadeeq Ali; Stefán Karl Sævarsson; Wan Abu Bakar Wan Abas
Related Documents :
3549583 - Double-blind, randomized, cross-over clinical trial of metoprolol and propranolol in mi...
1720483 - Does antihypertensive therapy affect the natural protection against thrombosis?
9756673 - An adsorption equation for an ultrathin fluid film.
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2012-11-14
Journal Detail:
Title:  Clinical biomechanics (Bristol, Avon)     Volume:  -     ISSN:  1879-1271     ISO Abbreviation:  Clin Biomech (Bristol, Avon)     Publication Date:  2012 Nov 
Date Detail:
Created Date:  2012-11-19     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  8611877     Medline TA:  Clin Biomech (Bristol, Avon)     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Copyright Information:
Copyright © 2012 Elsevier Ltd. All rights reserved.
Affiliation:
Department of Biomedical Engineering, Faculty of Engineering, University of Malaya, 50603 Kuala Lumpur, Malaysia. Electronic address: arezoo@um.edu.my.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Replacement of endoprosthetic implants within a two years follow-up period: a statutory health insur...
Next Document:  Functional neuroimages of cortical myoclonus altered by levetiracetam in a patient with sialidosis.