| An evaluation study on the quietness of the ATS valve. | |
| | |
MedLine Citation:
|
PMID: 17592425 Owner: NLM Status: MEDLINE |
Abstract/OtherAbstract:
|
BACKGROUND: The closure sound of the ATS bileaflet mechanical valve is said to be quieter than that of the other mechanical valves. However, the reasons for this are still unknown. In this study, we investigated the reasons for the quietness of the ATS valve closure sound. PATIENTS AND METHODS: The valve closure sound was evaluated in 70 patients and in another 70 patients in whom the SJM valve had been used for single valve replacement, based on frequency analysis of the closure sound, measurement of the opening angle of the valve, cardiac function, and patient interviews. RESULTS: In the valve closure sound analysis, the mean peak frequency of the valve closure sound was 1.02 kHz for the ATS valve, and the mean pressure was 22.8+/-4.04 dB. The mean peak frequency of the closure sound of the SJM valve was1.02 kHz, with another intermittent peak at 3 to 9 kHz in the human audibility range. The mean sound pressure was 25.0+/-3.20 dB. The noise classification score was 2.07+/-1.95 points for the SJM valve, significantly higher as compared with that for the ATS valve which was 0.36+/-0.95 points. Multilateral examinations showed a significant difference in the mean opening angle between the ATS and the SJM valves: the angle was 76.6+/-4.67 degrees for the ATS valve and 82.3+/-2.05 degrees for the SJM valve. CONCLUSION: In view of the lower sound pressure in the human audibility range and lower patient awareness of the valve closure sound, the ATS valve would appear to be a superior mechanical valve when compared to the SJM valve from the point of view of the quality of life of the patients. The significant difference in the opening angle in patients with the ATS valve between those who were aware of the valve closure sound and those who were not suggested a possible association between the opening angle and the patient awareness of the valve closure sound. |
| | |
Authors:
|
Tomofumi Umeda |
Related Documents
:
|
23673175 - Bidirectional ventricular tachycardia of unknown etiology. 1261315 - Pacemaker-induced change in prosthetic valvular sounds. 7480415 - "lazarus stand forth" h. d. encounters freud. 21120705 - Gender differences in the phosphorus content of the sino-atrial nodes and other cardiac... 9687825 - Difference in systolic motion velocity of the left ventricular posterior wall in patien... 18525095 - Acute myocardial infarction found by multi-detector computed tomography ordered for sus... |
Publication Detail:
|
Type: Evaluation Studies; Journal Article |
Journal Detail:
|
Title: Annals of thoracic and cardiovascular surgery : official journal of the Association of Thoracic and Cardiovascular Surgeons of Asia Volume: 13 ISSN: 1341-1098 ISO Abbreviation: Ann Thorac Cardiovasc Surg Publication Date: 2007 Jun |
Date Detail:
|
Created Date: 2007-06-26 Completed Date: 2007-08-24 Revised Date: - |
Medline Journal Info:
|
Nlm Unique ID: 9703158 Medline TA: Ann Thorac Cardiovasc Surg Country: Japan |
Other Details:
|
Languages: eng Pagination: 172-7 Citation Subset: IM |
Affiliation:
|
Department of Cardiovascular Surgery, Nihon University School of Medicine, Tokyo, Japan. |
Export Citation:
|
APA/MLA Format Download EndNote Download BibTex |
| MeSH Terms | |
Descriptor/Qualifier:
|
Adult Aged Aged, 80 and over Aortic Valve Blood Pressure Female Heart Valve Prosthesis* Humans Male Middle Aged Mitral Valve Noise* Patient Satisfaction Prosthesis Design |
From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine
Previous Document: Outcomes and hemodynamics after aortic valve replacement: a comparison of stentless versus mechanica...