Document Detail


The effect of water molecular self-diffusion on quantitative high-resolution MRI polymer gel dosimetry.
MedLine Citation:
PMID:  14529209     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
In polymer gel dosimetry, magnetic resonance imaging (MRI) is used to determine the spin-spin relaxation rate (R2) which in turn can be correlated with absorbed dose to provide a map of the spatial distribution of the absorbed dose in the irradiated dosimeter. High accuracy, precision and reproducibility of these dose maps are essential. Moreover, for dose verification around brachytherapy sources used for intravascular brachytherapy, a high spatial resolution is required (typically 0.01-0.1 mm). To achieve these microscopic resolutions, strong imaging gradients are applied. The Brownian motion of water molecules in the presence of these strong magnetic field gradients causes an attenuation of the MR signal. When using a multiple spin-echo sequence, this may result in a significant deviation in the measured R2. The diffusion-related change in R2 at high resolutions was investigated experimentally and correlated with predictions that were obtained numerically and algebraically. Diffusion weighting is determined by the self-diffusion coefficient D, and imaging parameters, quantified by the b-factor. The b-factor was calculated for a multiple spin-echo sequence for different gradient strengths and gradient pulse durations. The variations in R2 that were observed when changing the matrix size and slice thickness are explained. It is shown that a linear correlation between the matrix size and the variation in R2 is based on the diffusion weighting caused by the read-out gradients and slice selective gradients. In conclusion, the essence of taking into account molecular self-diffusion to quantify variations in the measured dose-R2 response when using high-resolution MRI in polymer gel dosimetry is emphasized.
Authors:
C Hurley; Y De Deene; R Meder; J M Pope; C Baldock
Related Documents :
15678549 - Detection and correction of frequency instabilities for volumetric 1h echo-planar spect...
2085559 - Magnetic resonance imaging simulator: a teaching tool for radiology.
9695149 - Detection of acute stroke with diffusion-weighted mri.
18297299 - Magnetic resonance imaging with the digisonic sp neurelec cochlear implant.
16598719 - Fast spin echo sequences with very long echo trains: design of variable refocusing flip...
3968259 - Frequency shift artifacts in mr imaging.
17702279 - Predicting wafer-lot output time with a hybrid fcm-fbpn approach.
16359979 - Gadolinium radiologic contrast is a useful alternative for hysterosalpingography in pat...
2135169 - Brain perfusion in acute encephalitis: relationship to prognosis studied using spect.
Publication Detail:
Type:  Comparative Study; Evaluation Studies; Journal Article; Research Support, Non-U.S. Gov't; Validation Studies    
Journal Detail:
Title:  Physics in medicine and biology     Volume:  48     ISSN:  0031-9155     ISO Abbreviation:  Phys Med Biol     Publication Date:  2003 Sep 
Date Detail:
Created Date:  2003-10-07     Completed Date:  2004-05-19     Revised Date:  2006-11-15    
Medline Journal Info:
Nlm Unique ID:  0401220     Medline TA:  Phys Med Biol     Country:  England    
Other Details:
Languages:  eng     Pagination:  3043-58     Citation Subset:  IM    
Affiliation:
School of Physical and Chemical Sciences, Queensland University of Technology, Brisbane, Queensland 4001, Australia.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Algorithms*
Artifacts
Computer Simulation
Diffusion
Gels / chemistry*,  radiation effects*
Linear Energy Transfer
Magnetic Resonance Imaging / methods*
Materials Testing / methods*
Models, Chemical*
Polymers / chemistry,  radiation effects
Quality Control
Radiometry / instrumentation,  methods*
Reproducibility of Results
Sensitivity and Specificity
Water / chemistry*
Chemical
Reg. No./Substance:
0/Gels; 0/Polymers; 7732-18-5/Water

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Monte Carlo simulations of a scintillation camera using GATE: validation and application modelling.
Next Document:  Medical personnel and patient dosimetry during coronary angiography and intervention.