Document Detail


The effect of object speed and direction on the performance of 3D speckle tracking using a 3D swept-volume ultrasound probe.
MedLine Citation:
PMID:  22025168     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
Three-dimensional (3D) soft tissue tracking using 3D ultrasound is of interest for monitoring organ motion during therapy. Previously we demonstrated feature tracking of respiration-induced liver motion in vivo using a 3D swept-volume ultrasound probe. The aim of this study was to investigate how object speed affects the accuracy of tracking ultrasonic speckle in the absence of any structural information, which mimics the situation in homogenous tissue for motion in the azimuthal and elevational directions. For object motion prograde and retrograde to the sweep direction of the transducer, the spatial sampling frequency increases or decreases with object speed, respectively. We examined the effect object motion direction of the transducer on tracking accuracy. We imaged a homogenous ultrasound speckle phantom whilst moving the probe with linear motion at a speed of 0-35 mm s⁻¹. Tracking accuracy and precision were investigated as a function of speed, depth and direction of motion for fixed displacements of 2 and 4 mm. For the azimuthal direction, accuracy was better than 0.1 and 0.15 mm for displacements of 2 and 4 mm, respectively. For a 2 mm displacement in the elevational direction, accuracy was better than 0.5 mm for most speeds. For 4 mm elevational displacement with retrograde motion, accuracy and precision reduced with speed and tracking failure was observed at speeds of greater than 14 mm s⁻¹. Tracking failure was attributed to speckle de-correlation as a result of decreasing spatial sampling frequency with increasing speed of retrograde motion. For prograde motion, tracking failure was not observed. For inter-volume displacements greater than 2 mm, only prograde motion should be tracked which will decrease temporal resolution by a factor of 2. Tracking errors of the order of 0.5 mm for prograde motion in the elevational direction indicates that using the swept probe technology speckle tracking accuracy is currently too poor to track homogenous tissue over a series of volume images as these errors will accumulate. Improvements could be made through increased spatial sampling in the elevational direction.
Authors:
Emma J Harris; Naomi R Miller; Jeffrey C Bamber; J Richard N Symonds-Tayler; Philip M Evans
Related Documents :
8035218 - Climbing fiber responses of purkinje cells to retinal image movement in cat cerebellar ...
9373958 - Characterization and modeling of p-type electrosensory afferent responses to amplitude ...
1194888 - Repetitive spikes in photoreceptor axons of the scorpion eye. invertebrate eye structur...
8730068 - Fractal noise strength in auditory-nerve fiber recordings.
6540198 - The control of rapid limb movement in the cat. iv. updating of ongoing isometric respon...
1957808 - Orientation in time: implications for psychopathology and psychotherapy.
Publication Detail:
Type:  Evaluation Studies; Journal Article     Date:  2011-10-25
Journal Detail:
Title:  Physics in medicine and biology     Volume:  56     ISSN:  1361-6560     ISO Abbreviation:  Phys Med Biol     Publication Date:  2011 Nov 
Date Detail:
Created Date:  2011-11-01     Completed Date:  2012-02-27     Revised Date:  2014-03-19    
Medline Journal Info:
Nlm Unique ID:  0401220     Medline TA:  Phys Med Biol     Country:  England    
Other Details:
Languages:  eng     Pagination:  7127-43     Citation Subset:  IM    
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Humans
Imaging, Three-Dimensional / methods*
Motion
Phantoms, Imaging
Respiration
Sensitivity and Specificity
Transducers
Ultrasonography / instrumentation,  methods*
Grant Support
ID/Acronym/Agency:
10588//Cancer Research UK

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  RNAi mediated gene knockdown and transgenesis by microinjection in the necromenic Nematode Pristionc...
Next Document:  Bio-inspired materials for parsing matrix physicochemical control of cell migration: A Review.