Document Detail


The effect of different sampling intervals on the measurement of intrapartum fetal heart rate variability.
MedLine Citation:
PMID:  9083315     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
OBJECTIVE: To test the hypothesis that increasing the sampling interval affects the intrapartum fetal heart rate (FHR) variability measurement. METHODS: Fetal electrocardiograms were obtained from women in labor. Using the peak of the fetal R wave, the R-R interval and FHR were calculated on a beat-to-beat basis. Retrospectively, the original data were repartitioned using different intervals (2-900 seconds) to generate a window of measurement (epoch). The mean value for each epoch and the last FHR in that epoch (epochal value) were compared with published animal and human data. Errors were quantified by comparing the epochal and mean values for each epoch. Fetal heart rate variability between epochs and within each epoch was compared. RESULTS: Fetal heart rate and R-R interval were measured in 146 cases. The FHR had a normal distribution (mean 140.1 beats per minute, +/- standard deviation [SD] 15.6, skew -0.07), but its inverse, the R-R interval, was not normally distributed (mean 432 milliseconds, +/- SD 52.4, skew 1.78). Using a single value for an epoch duration of 2 seconds resulted in an error that was similar to the within-epoch variability (+/- SD of 2.2 beats per minute difference between mean and epochal value compared to +/- SD of 2 beats per minute within epoch) but which increased with epoch duration. CONCLUSION: An epoch duration of 2 seconds and a single sampled value within this period may be appropriate for measurement of both medium and long-term variability in any computerized intrapartum FHR interpretation system. Fetal heart rate (not R-R interval, because of its normal distribution) should be used to design such a computerized system.
Authors:
M A Wilcox; W Wang; D S Sahota; R R Dawkins; T K Chung; A M Chang
Related Documents :
16594915 - Fetal pulse oximetry and wavelet analysis of the fetal heart rate in the evaluation of ...
20701515 - Fetal loss in threatened abortion after demonstration of fetal cardiac activity in a lo...
7360445 - Documentation of recent fetal demise with simultaneous maternal and fetal heart rate mo...
3970095 - The distribution of accelerations of the human fetal heart rate at 38 to 40 weeks' gest...
15140105 - Extra-pair paternity does not result in differential sexual selection in the mutually o...
12555985 - Case-control study of early-term abortions (early fetal losses) associated with mare re...
Publication Detail:
Type:  Clinical Trial; Comparative Study; Journal Article    
Journal Detail:
Title:  Obstetrics and gynecology     Volume:  89     ISSN:  0029-7844     ISO Abbreviation:  Obstet Gynecol     Publication Date:  1997 Apr 
Date Detail:
Created Date:  1997-04-25     Completed Date:  1997-04-25     Revised Date:  2009-10-26    
Medline Journal Info:
Nlm Unique ID:  0401101     Medline TA:  Obstet Gynecol     Country:  UNITED STATES    
Other Details:
Languages:  eng     Pagination:  577-80     Citation Subset:  AIM; IM    
Affiliation:
Department of Obstetrics and Gynaecology, The Chinese University of Hong Kong.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Adult
Bias (Epidemiology)
Electrocardiography / methods
Female
Heart Rate, Fetal*
Humans
Labor, Obstetric*
Pregnancy
Time Factors
Comments/Corrections
Comment In:
Obstet Gynecol. 1997 Aug;90(2):318-9   [PMID:  9241319 ]

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Risk factors for recurrence of hemorrhagic endovasculitis of the placenta.
Next Document:  A randomized comparison between misoprostol and dinoprostone for cervical ripening and labor inducti...