Document Detail


The effect of balloon angioplasty on vasa vasorum blood flow in canine coronary arteries.
MedLine Citation:
PMID:  2147349     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
To assess the effects of balloon dilatation on vasa vasorum flow, we performed percutaneous transluminal coronary angioplasty on the circumflex arteries of 12 dogs. Left anterior descending and circumflex coronary vasa vasorum flows were measured with radioactive microspheres at baseline, during, and 10 minutes after a 3-minute, 8 atm balloon inflation. With inflation, vasa vasorum flow at the balloon dilatation site profoundly decreased (from 0.25 +/- 0.08 to 0.03 +/- 0.01 ml/min/gm). The flow returned to normal within 10 minutes after deflation. This effect was not mediated by hemodynamic deterioration during coronary occlusion and did not occur in the contralateral coronary artery. Endomyocardial flow in the distribution of the dilated artery decreased markedly during balloon inflation (from 1.14 +/- 1.9 to 0.08 +/- 0.04 ml/min/gm), which confirmed coronary occlusion. We conclude that a prolonged decrease in vasa vasorum flow is not produced by experimental balloon angioplasty, which makes it unlikely that a sustained vasa vasorum flow reduction plays a role in the maintenance of patency or the induction of restenosis.
Authors:
A C Eisenhauer; K Alker; R Kloner; R V Matthews
Related Documents :
1253189 - Effects of drugs on the negative (backflow) component of velocity patterns in the dog a...
7059329 - Regional distribution of cardiac output in unanesthetized baboons during +gz stress wit...
9006289 - Determination of coronary flow measurements by transesophageal echocardiography: depend...
3922209 - Effect of intracoronary nitroglycerin on myocardial blood flow and distribution in paci...
9813749 - Absolute volumetric coronary blood flow measurement with digital subtraction angiography.
9093529 - Perfusion-induced changes in cardiac contractility and oxygen consumption are not endot...
22585749 - Blood glucose determination: plasma or serum?
15576619 - Hematotoxicity in workers exposed to low levels of benzene.
7810709 - Effects of endothelium-derived nitric oxide on skin and digital blood flow in humans.
Publication Detail:
Type:  Comparative Study; Journal Article    
Journal Detail:
Title:  American heart journal     Volume:  120     ISSN:  0002-8703     ISO Abbreviation:  Am. Heart J.     Publication Date:  1990 Dec 
Date Detail:
Created Date:  1991-01-09     Completed Date:  1991-01-09     Revised Date:  2006-11-15    
Medline Journal Info:
Nlm Unique ID:  0370465     Medline TA:  Am Heart J     Country:  UNITED STATES    
Other Details:
Languages:  eng     Pagination:  1285-91     Citation Subset:  AIM; IM    
Affiliation:
Heart Institute of the Hospital of the Good Samaritan, Los Angeles, California 90017.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Angioplasty, Balloon* / instrumentation,  methods
Animals
Blood Flow Velocity / physiology
Blood Pressure / physiology
Coronary Angiography
Coronary Circulation / physiology*
Dogs
Female
Heart Rate / physiology
Male
Vasa Vasorum / physiology*

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine