The effect of applied sensor contact force on pulse transit time.
MedLine Citation:
PMID:  16772666     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
Pulse transit time (PTT) is usually determined as the time interval between the peak of the electrocardiogram (ECG) R wave and a characteristic point of the peripheral pulse measured by photoplethysmography. However, it was found that the photoplethysmogram (PPG) is affected by the contact force between the photoplethysmographic sensor and the measurement site, i.e. finger. Therefore, we hypothesized that the PTT may be altered by the applied sensor contact force. An ECG and PPG were recorded simultaneously from 30 healthy subjects using 12 magnitudes of contact force (0.1 N-1.8 N). Three characteristic points of the PPG were selected to determine the PTT, including the points near the foot (PTT1), on the systole phase (PTT2) and near the peak (PTT3). Both PTT1 and PTT2 increased significantly (p = 0.014 for PTT1 and p = 0.038 for PTT2) with the sensor contact force until the transmural force reached -0.1 N. With further increase in the contact force, they kept at an almost constant level. Such a changing trend was not found in PTT3. The results of this study suggest that the applied sensor contact force should be carefully controlled in PTT measurement to avoid diminishing its value as a diagnostic tool.
Authors:
X F Teng; Y T Zhang
Related Documents :
11117456 - Rate of force development and the lateralized readiness potential.
22026606 - Schooling behaviour of juvenile pacific bluefin tuna thunnus orientalis depends on thei...
15882796 - Anticipatory covariation of finger forces during self-paced and reaction time force pro...
22126616 - Fluorescence photobleaching of ala and ala-heptyl ester induced protoporphyrin ix durin...
16391496 - Timing and communicative functions of pitch contours.
24177966 - Circadian rhythm and fast responses to blue light of photosynthesis in ectocarpus (phae...
Publication Detail:
Type:  Journal Article; Research Support, Non-U.S. Gov't     Date:  2006-05-26
Journal Detail:
Title:  Physiological measurement     Volume:  27     ISSN:  0967-3334     ISO Abbreviation:  Physiol Meas     Publication Date:  2006 Aug 
Date Detail:
Created Date:  2006-06-14     Completed Date:  2006-10-05     Revised Date:  2006-11-15    
Medline Journal Info:
Nlm Unique ID:  9306921     Medline TA:  Physiol Meas     Country:  England    
Other Details:
Languages:  eng     Pagination:  675-84     Citation Subset:  IM    
Affiliation:
The Joint Research Center for Biomedical Engineering, Department of Electronic Engineering, The Chinese University of Hong Kong, Shatin, NT, Hong Kong.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Adult
Blood Pressure / physiology
Body Temperature / physiology
Electrocardiography*
Female
Heart Rate / physiology
Humans
Male
Photoplethysmography
Pulsatile Flow / physiology*
Pulse*
Time

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Experimental analysis of pendelluft flow generated by HFOV in a human airway model.
Next Document:  Evaluation of blood pressure changes using vascular transit time.