Document Detail


The distance between the vein and lesions predicts the requirement of carina ablation in circumferential pulmonary vein isolation.
MedLine Citation:
PMID:  21227954     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
Aims Additional ablation in the pulmonary vein (PV) carina region is sometimes required to achieve electrical isolation following circumferential pulmonary vein isolation (PVI). This study investigated the procedural predictors for the requirement of additional carina ablation to achieve complete electrical isolation with PVI. Methods and results Eighty patients with drug-refractory paroxysmal AF underwent circumferential PVI. After the first round of PVI, we placed circular catheters inside the veins to identify the residual PV potentials, and also performed electroanatomic mapping to observe the earliest activation sites during sinus rhythm. The requirement of an additional gap and carina ablation, and the optimal distance that predicted an incomplete PV block were assessed. In the first 40 patients, 43% of the ipsilateral PVs were electrically isolated after the initial PVI. Subsequent ablation of the gaps and ablation of the carina were required in the remaining 57% PVs. The only predictor of the requirement of carina ablation was the mean distance between the lesion-related scar and the ostia (P = 0.03). The longer the distance from the isolating lesions to the PV ostia (>8 mm) predicted an incomplete PV isolation after the first round of circumferential isolation. In the next 40 patients, a fixed distance of 8 mm to the PV ostia decreased the requirement of a carina ablation and resulted in a shorter procedure time (P < 0.05). Conclusions This study indicated the importance of complete linear lesions and additional carina ablation when the wide area circumferential PV isolation was applied.
Authors:
Yenn-Jiang Lin; Hsuan-Ming Tsao; Shih-Lin Chang; Li-Wei Lo; Ta-Chuan Tuan; Yu-Feng Hu; Wen-Chin Tsai; Chien-Jung Chang; Ching-Tai Tai; Kazuyoshi Suenari; Shih-Yu Huang; Tsu-Juey Wu; Shih-Ann Chen
Related Documents :
9291764 - Airway obstruction following internal jugular vein cannulation.
12674184 - Successful closure of iatrogenic femoral artery pseudoaneurysm: a new minimally invasiv...
16732444 - Pseudoaneurysm formation following carotid endarterectomy: two case reports and a liter...
11292914 - Treatment of ruptured anastomotic aneurysm by endograft.
15821384 - B-lynch brace suture: an effective method of conservative surgical management for place...
22843654 - C-reactive protein/interleukin-6 ratio as marker of the size of the uncomplicated thora...
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2011-1-11
Journal Detail:
Title:  Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology     Volume:  -     ISSN:  1532-2092     ISO Abbreviation:  -     Publication Date:  2011 Jan 
Date Detail:
Created Date:  2011-1-13     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  100883649     Medline TA:  Europace     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Affiliation:
1Division of Cardiology, Department of Medicine, Taipei Veterans General Hospital, 201, Sec. 2, Shih-Pai Road, Taipei, Taiwan, Republic of China.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  A novel manoeuvre for discerning supraventricular tachycardia mechanism.
Next Document:  Cardiac magnetic resonance imaging at 1.5 T in patients with cardiac rhythm devices.