Document Detail


The development of binary Mg-Ca alloys for use as biodegradable materials within bone.
MedLine Citation:
PMID:  18191191     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
Binary Mg-Ca alloys with various Ca contents were fabricated under different working conditions. X-ray diffraction (XRD) analysis and optical microscopy observations showed that Mg-xCa (x=1-3 wt%) alloys were composed of two phases, alpha (Mg) and Mg2Ca. The results of tensile tests and in vitro corrosion tests indicated that the mechanical properties could be adjusted by controlling the Ca content and processing treatment. The yield strength (YS), ultimate tensile strength (UTS) and elongation decreased with increasing Ca content. The UTS and elongation of as-cast Mg-1Ca alloy (71.38+/-3.01 MPa and 1.87+/-0.14%) were largely improved after hot rolling (166.7+/-3.01 MPa and 3+/-0.78%) and hot extrusion (239.63+/-7.21 MPa and 10.63+/-0.64%). The in vitro corrosion test in simulated body fluid (SBF) indicated that the microstructure and working history of Mg-xCa alloys strongly affected their corrosion behaviors. An increasing content of Mg2Ca phase led to a higher corrosion rate whereas hot rolling and hot extrusion could reduce it. The cytotoxicity evaluation using L-929 cells revealed that Mg-1Ca alloy did not induce toxicity to cells, and the viability of cells for Mg-1Ca alloy extraction medium was better than that of control. Moreover, Mg-1Ca alloy pins, with commercial pure Ti pins as control, were implanted into the left and right rabbit femoral shafts, respectively, and observed for 1, 2 and 3 months. High activity of osteoblast and osteocytes were observed around the Mg-1Ca alloy pins as shown by hematoxylin and eosin stained tissue sections. Radiographic examination revealed that the Mg-1Ca alloy pins gradually degraded in vivo within 90 days and the newly formed bone was clearly seen at month 3. Both the in vitro and in vivo corrosion suggested that a mixture of Mg(OH)2 and hydroxyapatite formed on the surface of Mg-1Ca alloy with the extension of immersion/implantation time. In addition, no significant difference (p>0.05) of serum magnesium was detected at different degradation stages. All these results revealed that Mg-1Ca alloy had the acceptable biocompatibility as a new kind of biodegradable implant material. Based on the above results, a solid alloy/liquid solution interface model was also proposed to interpret the biocorrosion process and the associated hydroxyapatite mineralization.
Authors:
Zijian Li; Xunan Gu; Siquan Lou; Yufeng Zheng
Publication Detail:
Type:  Journal Article; Research Support, Non-U.S. Gov't     Date:  2008-01-11
Journal Detail:
Title:  Biomaterials     Volume:  29     ISSN:  0142-9612     ISO Abbreviation:  Biomaterials     Publication Date:  2008 Apr 
Date Detail:
Created Date:  2008-01-29     Completed Date:  2008-07-11     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  8100316     Medline TA:  Biomaterials     Country:  England    
Other Details:
Languages:  eng     Pagination:  1329-44     Citation Subset:  IM    
Affiliation:
LTCS, College of Engineering, Peking University, Beijing 100871, China.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Alloys / chemistry*,  pharmacology
Animals
Biocompatible Materials / chemistry,  pharmacology
Bone and Bones*
Calcium / chemistry*
Cell Line
Cell Survival / drug effects
Durapatite / chemistry
Magnesium / chemistry*
Mice
Rabbits
X-Ray Diffraction
Chemical
Reg. No./Substance:
0/Alloys; 0/Biocompatible Materials; 1306-06-5/Durapatite; 7439-95-4/Magnesium; 7440-70-2/Calcium

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Dermal matrix as a carrier for in vivo delivery of human adipose-derived stem cells.