A comparison of different experimental methods for general recombination correction for liquid ionization chambers.
MedLine Citation:
PMID:  23060077     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
Radiation dosimetry of highly modulated dose distributions requires a detector with a high spatial resolution. Liquid filled ionization chambers (LICs) have the potential to become a valuable tool for the characterization of such radiation fields. However, the effect of an increased recombination of the charge carriers, as compared to using air as the sensitive medium has to be corrected for. Due to the presence of initial recombination in LICs, the correction for general recombination losses is more complicated than for air-filled ionization chambers. In the present work, recently published experimental methods for general recombination correction for LICs are compared and investigated for both pulsed and continuous beams. The experimental methods are all based on one of two approaches: either measurements at two different dose rates (two-dose-rate methods), or measurements at three different LIC polarizing voltages (three-voltage methods). In a comparison with the two-dose-rate methods, the three-voltage methods fail to achieve accurate corrections in several instances, predominantly at low polarizing voltages and dose rates. However, for continuous beams in the range of polarizing voltages recommended by the manufacturer of the LICs used, the agreement between the different methods is generally within the experimental uncertainties. For pulsed beams, the agreement between the methods is poor. The inaccuracies found in the results from the three-voltage methods are associated with numerical difficulties in solving the resulting equation systems, which also make these methods sensitive to small variations in the experimental data. These issues are more pronounced for the case of pulsed beams. Furthermore, the results suggest that the theoretical modelling of initial recombination used in the three-voltage methods may be a contributing factor to the deviating results observed.
Authors:
Jonas Andersson; Franz-Joachim Kaiser; Faustino Gómez; Oliver Jäkel; Juan Pardo-Montero; Heikki Tölli
Related Documents :
18244757 - A robust position/force learning controller of manipulators via nonlinear hinfinity con...
19273007 - Adaptive sliding-mode control for nonlinear systems with uncertain parameters.
17411267 - Interactions between short-term and long-term cardiovascular control mechanisms.
17418847 - Embedded model control: application to web winding.
24672307 - Fixed point results for generalized chatterjea type contractive conditions in partially...
11900127 - Passively q-switched quasi-three-level laser and its intracavity frequency doubling.
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2012-10-12
Journal Detail:
Title:  Physics in medicine and biology     Volume:  57     ISSN:  1361-6560     ISO Abbreviation:  Phys Med Biol     Publication Date:  2012 Oct 
Date Detail:
Created Date:  2012-10-12     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  0401220     Medline TA:  Phys Med Biol     Country:  -    
Other Details:
Languages:  ENG     Pagination:  7161-7175     Citation Subset:  -    
Affiliation:
Department of Radiation Sciences, Radiation Physics, University of Umeå, SE-901 85 Umeå, Sweden.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Highly Efficient Electrocatalytic Hydrogen Production by MoS(x) Grown on Graphene-Protected 3D Ni Fo...
Next Document:  Patterns of HIV and sexually transmitted infection testing among men who have sex with men couples i...