Objectives: To compare bicarbonate kinetics and acid base status in HD and HDF for the same patient; and to investigate the effect of patient physiologic parameters on these kinetics. Methods: In order to monitor HCO3- kinetics during dialysis, acid-base parameters, pH, blood gases partial pressures, and HCO3- concentrations were recorded during 3 regular dialysis (HD) and 3 on-line post-dilution HDF sessions performed on 12 patients, using same dialysis fluid with a 38 mmol/l HCO3- concentration. HCO3- mass transfers through the hemodialyzers membranes and into the patients were continuously calculated during the sessions from HCO3- concentrations, together with HCO3-dialysance. The"apparent" HCO3-gain was calculated by integrating over time the instantaneous mass transfer from dialyzer and re-infusion fluid to the patient. A second method consisted in calculating the patient apparent bicarbonate space (ABS) and HCO3- mass (ABS times plasma concentration) at beginning and end of session. Results: No significant differences were observed between acid base parameters at the end of HD and HDF sessions. In contrast to urea clearances, HCO3- dialysances decayed with time during sessions from 110 to 140 ml/min to about 40 ml/min after one hour. The net HCO3- gain was taken as the difference between final and initial HCO3-masses. This net gain was in average 63% of apparent gain in HD and 74% in HDF. Conclusions: Uremic acidosis was well corrected without risk of alkalosis. An unexpected result was the continuous decay of bicarbonate dialysance both in HD and HDF during runs.
Authors:
Hélène Morel; Michel Y Jaffrin; Clément Lux; Marianne Renou; Claire Fessier; Abir Petit; Philippe Morinière; Cécile Legallais
Related Documents :
10206806 - Sonographically guided fine needle aspiration biopsy of abdominal lymph nodes: experien...
11002366 - Follow-up of morphologically reactive lymphoid proliferations in fine-needle aspirates ...
3704666 - Studies of the bone marrow in polycythemia vera and the evolution of myelofibrosis and ...
2306956 - Pneumothorax following transbronchial biopsy. low diagnostic yield with routine chest r...
9804466 - Cardiac troponin i in patients receiving renal replacement therapy.
20374346 - The manifestations of vasculopathy in systemic sclerosis and its evidence-based therapy.
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2012-4-11
Journal Detail:
Title:  The International journal of artificial organs     Volume:  -     ISSN:  1724-6040     ISO Abbreviation:  -     Publication Date:  2012 Apr 
Date Detail:
Created Date:  2012-4-16     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  7802649     Medline TA:  Int J Artif Organs     Country:  -    
Other Details:
Languages:  ENG     Pagination:  0     Citation Subset:  -    
Affiliation:
Technological University of Compiègne, Dept of Biological Engineering, Compiègne - France.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Cubic Molecularly Imprinted Polymer Nanoparticles with a Fluorescent Core.
Next Document:  Computational modeling of effects of mechanical shaking on hemodynamics in hollow fibers.