A comparison between the oscillometric and the auscultatory method for ambulatory 24 h blood pressure monitoring.
MedLine Citation:
PMID:  10226224     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
OBJECTIVES: To investigate the compatibility between oscillometric and auscultatory methods, and to determine whether one is preferable over the other for ambulatory 24 h blood pressure monitoring. METHODS: For the blood pressure monitoring system we used an A&D TM 2421 device (Takeda), which enabled us to measure the blood pressure simultaneously with the two methods on the same arm. Our investigation included 281 patients (122 women and 159 men, aged 18-85 years) with suspected hypertension or undergoing treatment for hypertension. RESULTS: We obtained 23 531 measurements by the oscillometric method, which was 98% of the maximal possible number, and 81% of the maximal possible number were obtained by the auscultatory methjod. We were able to compare 98% of the paired measurements. The auscultatory method showed a uniform distribution of errors throughout the 24 h. Compared to the auscultatory method, the oscillometry method had fewer errors in the evenings, but more when the subjects were at work. There was a difference in paired single readings between the two methods amounting to 1.4+/-19 mmHg (mean+/-SD) for systolic and -2.4+/-18 mmHg for diastolic readings (auscultatory - oscillometric). The differences in mean values for the 281 cases of 24 h monitoring amounted to 0.7+/- 4 mmHg for systolic and -2.2+/-6 mmHg for diastolic measurements. For the mean systolic blood pressure, we found a difference of 0.3+/-4 mmHg in the daytime and 0.3+/-8 mmHg during the night. The mean diastolic pressures differed by -2.0+/-6 mmHg in the daytime and -1.6+/-8 mmHg during the night. We found only a weak correlation between the differences in the readings by the two methods and systolic blood pressure levels, age, pulse pressure and body mass index, and no correlations between these differences and the diastolic blood pressure levels. CONCLUSION: Although we found a considerable SD on single readings by the two methods, there was a good agreement between the mean values of the 24 h monitoring for the two methods. We obtained a significantly higher success rate by the oscillometric method. The findings suggest that, for this equipment, the oscillometric method is preferable for 24 h ambulatory blood pressure monitoring because it provides a much higher rate of successful readings.
Authors:
Wiinberg; Raymond; Bang; Malmqvist; Svendsen; Petersen
Related Documents :
16205444 - Automated assessment of blood pressure using bptru compared with assessments by a train...
17664684 - On measuring the instantaneous blood pressure in an artery via the tissue control method.
923554 - The value of arterial blood pressure measurement in assessing the prognosis in equine c...
2632744 - Comparison of finapres non-invasive beat-to-beat finger blood pressure with intrabrachi...
8070944 - Characterization of left ventricle function by analysis of pressure responses to steps ...
20825784 - Revolutionary advances in enhancing patient comfort on patients transported on a backbo...
Publication Detail:
Type:  JOURNAL ARTICLE    
Journal Detail:
Title:  Blood pressure monitoring     Volume:  1     ISSN:  1473-5725     ISO Abbreviation:  Blood Press Monit     Publication Date:  1996 Jun 
Date Detail:
Created Date:  1999-05-04     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  9606438     Medline TA:  Blood Press Monit     Country:  -    
Other Details:
Languages:  ENG     Pagination:  187-191     Citation Subset:  -    
Affiliation:
Frederiksberg Hospital, Department of Clinical Physiology, Frederiksberg, Denmark.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Auscultatory and oscillometric methods of ambulatory blood pressure monitoring, advantages and limit...
Next Document:  Beyond blood pressure measurements: monitoring of the appearance time of Korotkoff sounds.