Document Detail


A comparison between disposable and reusable single fiber needle electrodes in relation to stimulated single fiber studies.
MedLine Citation:
PMID:  22119663     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
OBJECTIVE: To compare disposable and reusable single fiber needle recordings in relation to stimulated single fiber studies. METHODS: At least 10 potentials were sampled using each needle type from each patient with a minimum of 20 sampled potentials per patient. For successive patients either a disposable or reusable electrode was used first to remove effects of adaptation or fatigue. RESULTS: Eighteen patients were prospectively recruited. No significant difference was found between disposable and reusable needle use with respect to mean consecutive difference with mean values (± standard deviation) of 25.29±18.56 and 23.64±16.80, respectively (p>0.05). With regards to amplitude there was a significant difference between the two types with the biggest potentials recorded with disposable (339.85±236.45) compared to reusable needles (248.23±196.43) (p<0.001). More potentials were obtained with disposable (2.73±1.29) compared to reusable needles (2.33±1.11) per acquisition run with the difference being statistically significant (0.01<p<0.05). CONCLUSIONS: Disposable single fibre needle electrodes obtained MCD values were comparable to those obtained with reusable single fibre needle electrodes but the amplitudes of the potentials were higher. The greater number of potentials obtained per acquisition run means that the examination can be performed quicker. SIGNIFICANCE: Disposable single fiber needle use avoids the risk of prion infections and performs better than reusable needles.
Authors:
Eleftherios S Papathanasiou; Eleni Zamba-Papanicolaou
Related Documents :
9425493 - Leeches in the larynx.
9230763 - Sand aspiration with near-drowning. radiographic and bronchoscopic findings.
1456073 - Folate, vitamin b12 and cognitive impairment in patients with alzheimer's disease.
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2011-11-24
Journal Detail:
Title:  Clinical neurophysiology : official journal of the International Federation of Clinical Neurophysiology     Volume:  -     ISSN:  1872-8952     ISO Abbreviation:  -     Publication Date:  2011 Nov 
Date Detail:
Created Date:  2011-11-28     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  100883319     Medline TA:  Clin Neurophysiol     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Copyright Information:
Copyright © 2011 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.
Affiliation:
EMG Laboratory, Clinical Sciences, The Cyprus Institute of Neurology and Genetics, Nicosia, Cyprus.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Error monitoring functions in response to an external feedback when an explicit judgement is require...
Next Document:  Novel Tanshinone II A ternary solid dispersion pellets prepared by a single-step technique: In vitro...