Document Detail


A comparison between QLAB and TomTec full volume reconstruction for real time three-dimensional echocardiographic quantification of left ventricular volumes.
MedLine Citation:
PMID:  17894576     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
OBJECTIVES: To compare the interobserver variability and accuracy of two different real time three-dimensional echocardiography (RT3DE) analyzing programs. METHODS: Forty-one patients (mean age 56 +/- 11 years, 28 men) in sinus rhythm with a cardiomyopathy and adequate 2D image quality underwent RT3DE and magnetic resonance imaging (MRI) within one day. Off-line left ventricular (LV) volume analysis was performed with QLAB V4.2 (semiautomated border detection with biplane projections) and TomTec 4D LV analysis V2.0 (primarily manual tracking with triplane projections and semiautomated border detection). RESULTS: Excellent correlations (R(2) > 0.98) were found between MRI and RT3DE. Bland-Altman analysis revealed an underestimated LV end-diastolic volume (LV-EDV) for both TomTec (-9.4 +/- 8.7 mL) and QLAB (-16.4 +/- 13.1 ml). Also, an underestimated LV end-systolic volume (LV-ESV) for both TomTec (-4.8 +/- 9.9 mL) and QLAB (-8.5 +/- 14.2 mL) was found. LV-EDV and LV-ESV were significantly more underestimated with QLAB software. Both programs accurately calculated LV ejection fraction (LV-EF) without a bias. Interobserver variability was 6.4 +/- 7.8% vs. 12.2 +/- 10.1% for LV-EDV, 7.8 +/- 9.7% vs. 13.6 +/- 11.2% for LV-ESV, and 7.1 +/- 6.9% vs. 9.7 +/- 8.8% for LV-EF for TomTec vs. QLAB, respectively. The analysis time was shorter with QLAB (4 +/- 2 minutes vs. 6 +/- 2 minutes, P < 0.05). CONCLUSIONS: RT3DE with TomTec or QLAB software analysis provides accurate LV-EF assessment in cardiomyopathic patients with distorted LV geometry and adequate 2D image quality. However, LV volumes may be somewhat more underestimated with the current QLAB software version.
Authors:
Osama I I Soliman; Boudewijn J Krenning; Marcel L Geleijnse; Attila Nemes; Robert-Jan van Geuns; Timo Baks; Ashraf M Anwar; Tjebbe W Galema; Wim B Vletter; Folkert J ten Cate
Related Documents :
11839406 - Respiratory motion compensation for 3-d freehand echocardiography.
7234656 - Real time computerization of two-dimensional echocardiography.
10577576 - Transthoracic echocardiography using second harmonic imaging: diagnostic alternative to...
9788456 - New concept in echocardiography: harmonic imaging of tissue without use of contrast agent.
17357736 - Mask design for optical microlithography--an inverse imaging problem.
21084456 - Studying hypertension in ocular fundus images using hausdorff dispersion ordering.
Publication Detail:
Type:  Comparative Study; Journal Article    
Journal Detail:
Title:  Echocardiography (Mount Kisco, N.Y.)     Volume:  24     ISSN:  0742-2822     ISO Abbreviation:  Echocardiography     Publication Date:  2007 Oct 
Date Detail:
Created Date:  2007-09-26     Completed Date:  2008-01-24     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  8511187     Medline TA:  Echocardiography     Country:  United States    
Other Details:
Languages:  eng     Pagination:  967-74     Citation Subset:  IM    
Affiliation:
Department of Cardiology, Thoraxcenter, Erasmus University Medical Center, Dr. Molewaterplein 40, 3015 GD Rotterdam, The Netherlands.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Algorithms
Cardiomyopathies / physiopathology,  ultrasonography*
Echocardiography, Three-Dimensional*
Female
Humans
Image Processing, Computer-Assisted
Linear Models
Magnetic Resonance Imaging
Male
Middle Aged
Observer Variation
Ventricular Dysfunction, Left / pathology,  ultrasonography*

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Evaluation of left atrial size in patients with atrial arrhythmias: comparison of standard 2D versus...
Next Document:  Blood flow imaging-a new angle-independent ultrasound modality for the visualization of flow in atri...