Document Detail


A comparison of the Pentax Airway Scope™ with the Airtraq™ in an infant manikin.
MedLine Citation:
PMID:  22506698     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
We compared the Pentax Airway Scope(TM) with the Airtraq(TM) optical laryngoscope in an infant manikin. Twenty-three anaesthetists randomly performed tracheal intubation: at rest, (a) with the Airway Scope and (b) with the Airtraq; and during chest compressions, (c) with the Airway Scope and (d) with the Airtraq. The success rate, modified Cormack and Lehane classification for glottic view, time taken to view the glottis, and time to place the tracheal tube were recorded. There was no difference in intubation success rate or quality of glottic view between the two devices. The median (IQR [range]) time taken to obtain a view of the glottis was 4.5 (3.7-6.4 [1.8-14.0]) s using the Airway Scope compared with 7.1 (5.5-9.6 [3.3-12.0]) s using the Airtraq (p = 0.001), and to successful placement of the tracheal tube was 8.3 (6.8-9.4 [3.7-20.7]) s using the Airway Scope compared with 11.2 (10.4-13.8 [4.9-23.7]) s using the Airtraq (p = 0.001). During chest compressions, the median (IQR [range]) time taken to view the glottis was 5.1 (4.0-7.2 [2.0-12.4]) s using the Airway Scope compared with 7.5 (5.0-13.2 [4.2-26.4]) s using the Airtraq (p = 0.006), and to successful placement of the tracheal tube was 9.5 (6.6-13.7 [4.5-16.2]) s using the Airway Scope compared with 11.7 (9.1-18.1 [6.2-37.4]) s using the Airtraq (p = 0.022). We conclude that both devices provided good quality views of the glottis and successful tracheal intubation in an infant manikin both at rest and during external chest compressions. Use of the Airway Scope resulted in a shorter time to view the glottis and perform successful tracheal intubation compared with the Airtraq.
Authors:
A Tampo; A Suzuki; S Sako; T Kunisawa; H Iwasaki; S Fujita
Related Documents :
6431068 - Prenatal exposure to polychlorinated biphenyls: effects on birth size and gestational age.
20383368 - Estimating personal pm2.5 exposures using co measurements in guatemalan households cook...
8092378 - The effect of paternal smoking on the birthweight of newborns whose mothers did not smo...
18571708 - Perinatal environmental tobacco smoke exposure alters the immune response and airway in...
16325598 - Noninvasive prenatal rhd genotyping by real-time polymerase chain reaction using plasma...
17590598 - Epidemiology of maternal mortality in saudi arabia.
Publication Detail:
Type:  Comparative Study; Journal Article     Date:  2012-04-16
Journal Detail:
Title:  Anaesthesia     Volume:  67     ISSN:  1365-2044     ISO Abbreviation:  Anaesthesia     Publication Date:  2012 Aug 
Date Detail:
Created Date:  2012-07-10     Completed Date:  2012-09-11     Revised Date:  2012-11-30    
Medline Journal Info:
Nlm Unique ID:  0370524     Medline TA:  Anaesthesia     Country:  England    
Other Details:
Languages:  eng     Pagination:  881-4     Citation Subset:  AIM; IM    
Copyright Information:
Anaesthesia © 2012 The Association of Anaesthetists of Great Britain and Ireland.
Affiliation:
Department of Emergency Medicine, Asahikawa Medical University Hospital, Asahikawa, Japan. atampo1031@gmail.com
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Humans
Infant
Intubation, Intratracheal / instrumentation*
Laryngoscopes*
Manikins*
Comments/Corrections
Comment In:
Anaesthesia. 2012 Nov;67(11):1276-7; author reply 1277   [PMID:  23033822 ]