| The clinical performance of the EGV1 self-monitoring blood glucose system. | |
| | |
MedLine Citation:
|
PMID: 22266375 Owner: NLM Status: Publisher |
Abstract/OtherAbstract:
|
BACKGROUND: The novel technique of blood volume detection can improve the reliability and accuracy of a self-monitoring blood glucose system. Self-management of diabetes can be improved, and the glycemic range can be efficiently controlled. METHODS: A total of 153 patients with diabetes mellitus participated in the clinical study. The accuracy, blood volume detection, interference, and altitude effect of the EGV1 self-monitoring blood glucose system were evaluated and compared among the fingerstick, alternative site testing, and venous blood. RESULTS: The EGV1 self-monitoring blood glucose system with fingertip demonstrated an excellent correlation with venous blood (linear regression analysis: slope=1.01, intercept=-0.8972mg/dl, r(2)=0.96), and with other brands of glucose systems (linear regression analysis: slope=0.99, intercept=+3.5632mg/dl, r(2)=0.94). The Clarke error grid analysis indicated that the results of fingertip and alternative sites were in the acceptable zones, A and B. The system required 0.6 ul of a blood sample to obtain an accurate reading, and was unaffected by several interferents and altitude. CONCLUSIONS: The EGV1 self-monitoring blood glucose system using various blood samples demonstrated acceptable accuracy and reliability compared to the laboratory reference and other self-monitoring blood glucose systems. |
| | |
Authors:
|
Chien-Chih Chen; Jui-Jane Lin; Sheng-Tien Hung; Peng-Ting Chun; Yiu-Kay Lai |
Related Documents
:
|
2923275 - Diameters and cross-sectional areas of branches in the human pulmonary arterial tree. 16508795 - Computational fluid dynamics: hemodynamic changes in abdominal aortic aneurysm after st... 8803635 - Influence of blood cells and blood flow on venous endothelium. 12700585 - Distributions of wall shear stress in venular convergences of mouse cremaster muscle. 15006575 - The width of a gastric tube has no impact on outcome after esophagectomy. 18697555 - Using flow information to support 3d vessel reconstruction from rotational angiography. |
Publication Detail:
|
Type: JOURNAL ARTICLE Date: 2012-1-14 |
Journal Detail:
|
Title: Clinica chimica acta; international journal of clinical chemistry Volume: - ISSN: 1873-3492 ISO Abbreviation: - Publication Date: 2012 Jan |
Date Detail:
|
Created Date: 2012-1-23 Completed Date: - Revised Date: - |
Medline Journal Info:
|
Nlm Unique ID: 1302422 Medline TA: Clin Chim Acta Country: - |
Other Details:
|
Languages: ENG Pagination: - Citation Subset: - |
Copyright Information:
|
Copyright © 2011. Published by Elsevier B.V. |
Affiliation:
|
Wei-Gong Memorial Hospital, Miaoli, Taiwan; The Institute of Biotechnology, College of Life Science, National Tsing Hua University, Hsinchu, Taiwan. |
Export Citation:
|
APA/MLA Format Download EndNote Download BibTex |
| MeSH Terms | |
Descriptor/Qualifier:
|
|
From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine
Previous Document: Regulation of Breast Cancer Resistant Protein (BCRP) by Peroxisome Proliferator-Activated Receptor A...
Next Document: The coiled coil motif in polymer drug delivery systems.