The changing distribution of arm circumferences in NHANES III and NHANES 2000 and its impact on the utility of the 'standard adult' blood pressure cuff.
MedLine Citation:
PMID:  14688551     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
BACKGROUND: Accurate blood pressure measurement is dependent on using a blood pressure cuff that is appropriate to the patient's arm circumference. OBJECTIVE: This study identifies the change in distribution of arm circumferences in the United States and its impact on usage of the 'standard adult' cuff. METHOD: The most current National Health and Nutritional Examination Survey (NHANES) data, available on the website (http://www.cdc.gov/nchswww/nchshome.htm), covers NHANES III (Cycle 1, 1988-1991; 8381 subjects and Cycle 2, 1991-1994; 8566 subjects) and NHANES 2000 (1999-2000; 4,444 subjects). The weighted change in arm circumference between NHANES III as a whole and NHANES 2000 was calculated. Correlates for increased arm circumference were obtained via multivariate analysis. The predicted change in blood pressure cuff usage based on the changing prevalence of arm circumferences was calculated. RESULTS: The mean arm circumference for the whole population increased significantly from NHANES III to NHANES 2000 (31.83 +/- 0.08 cm versus 32.86 +/- 0.15 cm, p < 0.001) and in the hypertension population without reaching statistical significance (33.07 +/- 0.16 to 33.61 +/- 0.30 cm, p = 0.11). When adjusted regressions were performed, the increases in arm circumference were due to increasing weight in both the whole population and the hypertensives. The numbers of Americans predicted to require the 'standard adult' cuff to accurately measure blood pressure decreased from 76.2% to 66.3% while the number of Americans increased from 42.2% to 45%. CONCLUSIONS: The increasing prevalence of overweight and obese Americans found in NHANES III and NHANES 2000 has led to larger mean arm circumferences in hypertensives and the total population. This increased frequency of larger arm circumferences predicts that the 'large adult' cuff will be increasingly required in clinician's offices for accurate blood pressure measurement.
Authors:
John W Graves; Kent R Bailey; Sheldon G Sheps
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Blood pressure monitoring     Volume:  8     ISSN:  1359-5237     ISO Abbreviation:  Blood Press Monit     Publication Date:  2003 Dec 
Date Detail:
Created Date:  2003-12-22     Completed Date:  2004-12-07     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  9606438     Medline TA:  Blood Press Monit     Country:  England    
Other Details:
Languages:  eng     Pagination:  223-7     Citation Subset:  IM    
Affiliation:
Division of Hypertension, Mayo Clinic and Mayo Foundation, Rochester, Minnesota 55905, USA. graves.john@mayo.edu
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Adult
Arm / anatomy & histology*
Blood Pressure Determination / methods*,  trends
Health Surveys
Humans
National Institutes of Health (U.S.)
United States
Comments/Corrections
Comment In:
Blood Press Monit. 2004 Apr;9(2):99; author reply 99-100   [PMID:  15096907 ]

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Tolerancing and budget in design and production of test lenses for calibration of focimeters.
Next Document:  Validation of a two-axis accelerometer for monitoring patient activity during blood pressure or ECG ...