The biomechanical effects of a deepened articular cavity during dynamic motion of the wrist joint.
MedLine Citation:
PMID:  22289408     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
BACKGROUND: A deepened articular cavity of the distal radius due to a metaphyseal comminution zone is associated with early osteoarthritis and reduced joint motion. As this deformity has not been investigated biomechanically, the purpose of this study was to evaluate the effects of a deepened articular cavity on contact biomechanics and motion range in a dynamic biomechanical setting. METHODS: Six fresh frozen cadaver forearms were tested in a force controlled test bench during dynamic flexion and extension and intact mean contact pressure and contact area as well as range of motion were evaluated. Malunion was then simulated and intraarticular as well as motion data were obtained. Intact and malunion data were compared for the scaphoid and lunate facet and the total radial joint surface. FINDINGS: Due to malunion simulation, cavity depth increased significantly. Motion decreased significantly to 54-69% when compared to the intact state. Malunion simulation led to a significant decrease of contact area in maximum extension for all locations (by ~50%). In maximum flexion and neutral position, contact area decrease was significant for the scaphoid fossa (by 51-54%) and the total radial joint surface (by 47-50%). Contact pressure showed a significant increase in maximum extension in the scaphoid fossa (by 129%). INTERPRETATION: Already a small cavity increase led to significant alterations in contact biomechanics of the radiocarpal joint and to a significant range of motion decrease. This could be the biomechanical cause for degenerative changes after the investigated type of malunion. We think that restoration of the normal distal radius shape can minimize osteoarthritis risk post trauma and improve radiocarpal motion.
Authors:
Stefanie Erhart; Werner Schmoelz; Rohit Arora; Martin Lutz
Related Documents :
11214328 - Acceptance of fresh chicken meat presented under three light sources.
22422028 - Mechanical determinants of 100-m sprint running performance.
20449058 - Progress and perspective of polymer white light-emitting devices and materials.
9056078 - A led light calibration source for dual-wavelength microscopy.
7775338 - Gas density does not affect pulmonary acoustic transmission in normal men.
3341158 - The effect of stimulus predictability and age on human tracking eye movements.
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2012-1-28
Journal Detail:
Title:  Clinical biomechanics (Bristol, Avon)     Volume:  -     ISSN:  1879-1271     ISO Abbreviation:  -     Publication Date:  2012 Jan 
Date Detail:
Created Date:  2012-1-31     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  8611877     Medline TA:  Clin Biomech (Bristol, Avon)     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Copyright Information:
Copyright © 2012 Elsevier Ltd. All rights reserved.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  E-cigarettes: promise or peril?
Next Document:  Flavone is efficient to protect zebrafish fins from UV-induced damage.