Document Detail


A bench test to confirm the core features of volume-assured non-invasive ventilation.
MedLine Citation:
PMID:  20199647     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
Volume-assured non-invasive ventilation (NIV) theoretically guarantees minute ventilation with circuit leak compensation unlike other modes of NIV. Bench testing demonstrated that minute ventilation was maintained with varying lung compliance and resistance with minimal effect from circuit leak, confirming for the first time the core features of volume-assured NIV. BACKGROUND AND OBJECTIVE: Volume-assured non-invasive positive pressure ventilation (va-NIPPV) is a novel mode designed to adapt pressure support (PS) to achieve a target minute ventilation (TgV). This may optimize ventilation; however, no data confirm that va-NIPPV compensates appropriately for the changes in pulmonary mechanics and circuit leak seen in clinical practice. Bench testing assessed these principles. METHODS: A ventilator featuring a va-NIPPV mode was studied. A test lung with varying compliance and resistance, and pneumotachograph were used. Eight lung model settings were chosen: (i) low resistance and high compliance; (ii) low resistance and low compliance; (iii) high resistance and high compliance; and (iv) high resistance and low compliance, all with and without additional circuit leak. An expiration valve, respiratory rate of 15, inspiratory time of 1 s and PS between 3 and 21 cm H2O were used. Va-NIPPV was tested with varying TgV after establishing the range of minute ventilation possible in a pressure preset mode. RESULTS: At a TgV of 10 L/min, va-NIPPV delivered minute ventilation of (median (interquartile range) ): 11 (10.9-11, 10.2 (10.2-10.3), 12.4 (12.4-12.4) and 11.2 (10.9-11.2) L/min in test lung settings 1, 2, 3 and 4, respectively. Additional leak between 8-33 L/min had little effect. Similar results were seen at other TgV, within the ventilator's PS capabilities. CONCLUSIONS: These data confirm that va-NIPPV is able to approximate a preset TgV with varying lung compliance and resistance, and that additional circuit leak has little effect on the delivered minute ventilation.
Authors:
Nicholas S Oscroft; Ian E Smith
Related Documents :
20232047 - Comparison of high-frequency oscillation and tracheal gas insufflation versus standard ...
8827747 - Pressure support ventilation increases cardiac output in neonates and infants.
273387 - Vocal cord closure. a cause of upper airway obstruction during controlled ventilation.
17404557 - Noninvasive ventilation with positive airway pressure in paediatric intensive care.
7817907 - Effects of exercise on plasma level of brain natriuretic peptide in congestive heart fa...
17930767 - Influence of pressure on the boson peak: stronger than elastic medium transformation.
Publication Detail:
Type:  Evaluation Studies; Journal Article; Research Support, Non-U.S. Gov't    
Journal Detail:
Title:  Respirology (Carlton, Vic.)     Volume:  15     ISSN:  1440-1843     ISO Abbreviation:  Respirology     Publication Date:  2010 Feb 
Date Detail:
Created Date:  2010-03-04     Completed Date:  2010-06-21     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  9616368     Medline TA:  Respirology     Country:  Australia    
Other Details:
Languages:  eng     Pagination:  361-4     Citation Subset:  IM    
Affiliation:
Respiratory Support and Sleep Centre, Papworth Hospital NHS Foundation Trust, Papworth Everard, Cambridge, UK. nickoscroft@doctors.net.uk
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Airway Resistance / physiology
Humans
Lung / physiology
Lung Compliance / physiology
Models, Biological*
Positive-Pressure Respiration / instrumentation*,  standards*
Respiratory Mechanics / physiology

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Oxidative stress in non-small cell lung cancer patients after chemotherapy: Association with treatme...
Next Document:  The role of nasal CPAP in obstructive sleep apnoea syndrome due to mandibular hypoplasia.