Document Detail


An asymptotic solution for the contact of two biphasic cartilage layers.
MedLine Citation:
PMID:  7798285     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
This study addresses the hypothesis that interstitial fluid plays a major role in the load support mechanism of articular cartilage. An asymptotic solution is presented for two contacting biphasic cartilage layers under compression. This solution is valid for identical thin (i.e. epsilon = h'/a'0 << 1), frictionless cartilage layers, and for the 'early' time response (i.e. t' << (h')2/HAk) after the application of a step load. An equilibrium asymptotic solution is also presented (i.e.t'-->infinity). Here h' is the thickness, a'0 is a characteristic contact radius, HA is the aggregate modulus and k is the permeability of the cartilage layer. A main conclusion from this analysis is that the fluid phase of cartilage plays a major role in providing load support during the first 100-200 s after contact loading. Further, the largest component of stress in cartilage is the hydrostatic pressure developed in the interstitial fluid. For tissue fluid volume fraction (porosity) in the range 0.6 < or = phi f < or = 0.8, k = O(10(-15) m4/Ns) and HA = O(1 MPa), the peak magnitude of the principal effective (or elastic) stress may be as low as 14% of the peak hydrostatic pressure within the tissue, or the contact stress at the surface. In effect, the interstitial fluid shields the solid matrix from high normal stresses and strains. The asymptotic solution also shows that pressure-sensitive film measurements of intra-articular contact stress do not measure the elastic stress at the surface, but they rather provide a measure of the interstitial fluid pressure. Finally, this analysis provides strong support for the hypothesis that, if sudden loading causes shear failure within the cartilage-bone layer structure, this failure would take place at the cartilage-bone interface, and the plane of failure would be either parallel or perpendicular to this interface.
Authors:
G A Ateshian; W M Lai; W B Zhu; V C Mow
Related Documents :
2527695 - Foot bearing pressure in patients with unilateral diabetic foot ulcers.
23121615 - Evaluation of the aspirant trial evaluation of vàclavìk j, sedlàk r, plachy m, et al...
20156245 - The effects of different saddle pads on forces and pressure distribution beneath a fitt...
12443955 - The influence of simulated wear upon the ability of insoles to reduce peak pressures du...
21171985 - Increased plasma soluble endoglin levels as an indicator of cardiovascular alterations ...
8987195 - Salt intake and blood pressure in rural and metropolitan mexico.
Publication Detail:
Type:  Journal Article; Research Support, Non-U.S. Gov't    
Journal Detail:
Title:  Journal of biomechanics     Volume:  27     ISSN:  0021-9290     ISO Abbreviation:  J Biomech     Publication Date:  1994 Nov 
Date Detail:
Created Date:  1995-01-26     Completed Date:  1995-01-26     Revised Date:  2009-11-11    
Medline Journal Info:
Nlm Unique ID:  0157375     Medline TA:  J Biomech     Country:  UNITED STATES    
Other Details:
Languages:  eng     Pagination:  1347-60     Citation Subset:  IM; S    
Affiliation:
Department of Mechanical Engineering, Columbia University, New York, NY 10032.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Adhesiveness
Algorithms
Bone and Bones / physiology
Cartilage, Articular / metabolism,  physiology*,  ultrastructure
Elasticity
Extracellular Space / physiology
Friction
Humans
Hydrostatic Pressure
Lubrication
Models, Biological*
Permeability
Porosity
Reproducibility of Results
Rheology
Stress, Mechanical
Synovial Fluid / metabolism,  physiology*
Time Factors
Viscosity
Weight-Bearing

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  A model of foot placement during gait.
Next Document:  Skeletal muscle stiffness in static and dynamic contractions.