The accuracy of power-spectrum analysis of heart-rate variability from annotated RR lists generated by Holter systems.
MedLine Citation:
PMID:  8081194     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
The accuracy of spectral analysis of heart-rate variability performed on annotated RR interval lists obtained from several commercial Holter systems was appraised. Five tape-recorder-based systems (Del Mar 750, Marquette 8000, Oxford Medilog Excel, Remco Cardioline AD 35 and Reynolds Pathfinder PA3) and four solid-state systems (Hewlett Packard 43420B, Marquette Seer, Oxford 6000FD2, Reynolds E-Ram) were considered. Two ECG signals with fixed real morphology but characterized by a different degree of modulation of the RR interval (reduced and normal variability) were fed into the recorders evaluated. The total power and the power in the very low-, low- and high-frequency bands were then estimated on all Holter-generated RR sequences. Spectral analysis was performed by both the autoregressive and fast-Fourier-transform methods. The estimation error of each parameter was statistically characterized and, for tape-recorder-based systems, inferential analysis was used to test for differences between recorders, tapes and times of recording. The centre and dispersion of the estimation error changed markedly from system to system. Some tape-recording systems showed large inter-recorder differences. The degree of spectral distortion was never uniform among selected bands. Solid-state systems performed better than tape-recording ones but both were limited in the accuracy by the quantization of RR interval measurement. The fast Fourier method yielded spectral estimates more stable than the autoregressive method. Our data clearly show that spectral analysis of very low-variability signals may be seriously affected by Holter recording and preprocessing of ECG signals.
Authors:
G D Pinna; R Maestri; A Di Cesare; R Colombo; G Minuco
Related Documents :
24806764 - Extracting representative information to enhance flexible data queries.
23652774 - Quantifying wikipedia usage patterns before stock market moves.
23333764 - Identifiability and estimation of multiple transmission pathways in cholera and waterbo...
23998504 - Modelling mitigation options to reduce diffuse nitrogen water pollution from agriculture.
22282374 - The factor structure of the 12-item general health questionnaire in a literate kenyan p...
21140524 - A guide to the design and analysis of small clinical studies.
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Physiological measurement     Volume:  15     ISSN:  0967-3334     ISO Abbreviation:  Physiol Meas     Publication Date:  1994 May 
Date Detail:
Created Date:  1994-10-11     Completed Date:  1994-10-11     Revised Date:  2004-11-17    
Medline Journal Info:
Nlm Unique ID:  9306921     Medline TA:  Physiol Meas     Country:  ENGLAND    
Other Details:
Languages:  eng     Pagination:  163-79     Citation Subset:  IM    
Affiliation:
Department of Biomedical Engineering, Clinica del Lavoro Foundation, IRCCS, Medical Centre of Rehabilitation, Montescano, Italy.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Electrocardiography
Electrocardiography, Ambulatory / instrumentation*,  standards
Fourier Analysis
Heart Rate / physiology*
Humans
Reference Values
Tape Recording

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Phantoms for studying the acceleration and turbulence of liquids using magnetic resonance imaging.
Next Document:  Quadrature-to-directional format conversion of Doppler signals using digital methods.