Document Detail


The accuracy of community-based automated blood pressure machines.
MedLine Citation:
PMID:  10836778     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
BACKGROUND: Despite widespread use, the accuracy of community-based automated blood pressure machines has been questioned. We sought to determine if these machines are as accurate and reliable as those obtained by a clinician with a mercury manometer. METHODS: We randomly selected 25 pharmacies and compared blood pressure readings obtained from their automated machines with from a mercury manometer. We used 3 volunteers with arm circumferences at the low, medium, and high ends of the acceptable range of a normal adult cuff size. RESULTS: For the subject with the small arm size, store machines reported systolic pressure readings that were, on average, 10 mm Hg higher than those obtained by the clinician (P <.001) and diastolic pressures 9 mm Hg higher (P <.001). The mean systolic pressure readings for the subject with the medium arm size were not significantly different between the store machine and the mercury manometer, and the readings were only modestly different for diastolic pressure. For the subject with the large arm size, store machines reported diastolic pressure readings that were, on average, 8.3 mm Hg lower than those obtained using the mercury manometer (P <.001), but with no significant difference in the systolic pressure. CONCLUSIONS: We found that automated blood pressure machines from a representative community-based sample of pharmacies did not meet the accepted standards of accuracy and reliability. Accuracy of readings is especially uncertain for patients having arm sizes larger or smaller than average.
Authors:
D J Van Durme; M Goldstein; N Pal; R G Roetzheim; E C Gonzalez
Related Documents :
9095818 - Caring for the intra-aortic balloon pump patient. most frequently asked nursing questions.
8212948 - Blood pressure in the sow: an attempt of indirect measuring ante partum.
2400078 - Blood pressure measurement during transport. a comparison of direct and oscillotonometr...
20594078 - Comparison of doppler ultrasonography and high-definition oscillometry for blood pressu...
16858968 - Successful epidural blood patch treatment for spontaneous low cerebrospinal pressure he...
24750978 - β-blockers in hypertension: studies and meta-analyses over the years.
Publication Detail:
Type:  Clinical Trial; Journal Article; Randomized Controlled Trial; Research Support, Non-U.S. Gov't    
Journal Detail:
Title:  The Journal of family practice     Volume:  49     ISSN:  0094-3509     ISO Abbreviation:  J Fam Pract     Publication Date:  2000 May 
Date Detail:
Created Date:  2000-06-14     Completed Date:  2000-06-14     Revised Date:  2006-11-15    
Medline Journal Info:
Nlm Unique ID:  7502590     Medline TA:  J Fam Pract     Country:  UNITED STATES    
Other Details:
Languages:  eng     Pagination:  449-52     Citation Subset:  AIM; IM    
Affiliation:
Department of Family Medicine, University of South Florida, Tampa 33612, USA. dvandurm@hsc.usf.edu
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Adult
Automation*
Blood Pressure Determination / instrumentation*,  standards
Florida
Humans
Hypertension / prevention & control
Pharmaceutical Services
Reproducibility of Results

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine