PURPOSE: To determine the accommodative accuracy of infants and young children before they had had any form of clinical intervention or treatment, in an attempt to determine the difference between 'normal' and 'abnormal' visual experience for these individuals.
METHODS: Nott retinoscopy was performed on 111 subjects in binocular viewing conditions at a viewing distance of 50 cm. The target was a naturalistic cartoon image with a broadband spatial frequency amplitude spectrum.
RESULTS: Accommodative accuracy was not related to age (4-90 months). In the group found to have no apparent clinical abnormality (n = 71), the mean lag in the more hyperopic meridian of the least ametropic eye was 0.34 diopters (D). When considering the group as a whole, those with less than approximately 4 D of hyperopia demonstrated similar lags, while those with higher hyperopia, amblyopia, or strabismus had more variable lags. An ROC analysis designed to detect hyperopia >5 D in any meridian, amblyopia and/or strabismus had an area under the curve of 0.90 (95% confidence interval [CI], 0.82 to 0.95), and for a lag criterion of 1.3 D had a sensitivity of 83.3% and a specificity of 96.5%.
CONCLUSIONS: These data from a relatively small but broad sampling of age and clinical status suggest that clinically normal young infants and children with low amounts of hyperopia have similar lags of accommodation from the first few months after birth. Subjects with greater than 4 D of hyperopia, or amblyopia or strabismus, have more variable lags and therefore evidence of abnormal visual experience.
Authors:
T Rowan Candy; Kathryn H Gray; Christy C Hohenbary; Don W Lyon
Publication Detail:
Type:  Journal Article; Research Support, N.I.H., Extramural     Date:  2012-01-17
Journal Detail:
Title:  Investigative ophthalmology & visual science     Volume:  53     ISSN:  1552-5783     ISO Abbreviation:  Invest. Ophthalmol. Vis. Sci.     Publication Date:  2012 Jan 
Date Detail:
Created Date:  2012-01-18     Completed Date:  2012-03-16     Revised Date:  2014-09-15    
Medline Journal Info:
Nlm Unique ID:  7703701     Medline TA:  Invest Ophthalmol Vis Sci     Country:  United States    
Other Details:
Languages:  eng     Pagination:  143-9     Citation Subset:  IM    
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Accommodation, Ocular / physiology*
Amblyopia / physiopathology*,  therapy
Child
Child, Preschool
Cross-Sectional Studies
Female
Humans
Hyperopia / physiopathology*
Infant
Male
Retinoscopy
Strabismus / physiopathology*,  therapy
Vision, Binocular / physiology
Grant Support
ID/Acronym/Agency:
R01 EY014460/EY/NEI NIH HHS; R01 EY014460/EY/NEI NIH HHS
Comments/Corrections

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Serum DJ-1/PARK 7 is a potential biomarker of choroidal nevi transformation.
Next Document:  ROC analysis of the accuracy of Noncycloplegic retinoscopy, Retinomax Autorefractor, and SureSight V...