Document Detail


Wrong biochemistry results: two case reports and observational study in 5310 patients on potentially misleading thyroid-stimulating hormone and gonadotropin immunoassay results.
MedLine Citation:
PMID:  12406989     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
BACKGROUND: Immunoassays are used in almost all medical and surgical specialties, but they suffer from interference from proteins such as antibodies in some patients' sera. Such interferences are usually reported in the literature only as case reports after the introduction of a new assay. METHODS: We undertook a prospective observational study on 5310 patients for whom the common immunoassay tests for thyroid-stimulating hormone (TSH) and/or gonadotropins were requested. All TSH and gonadotropin results were critically assessed for a mismatch between the clinical details and analytical results to identify samples suspected of analytical unreliability. These were tested further by three approaches to screen for interference. RESULTS: From the 5310 sets of results, 59 patients' samples were identified as suspect and were tested further. Analytically incorrect results were found in 28 (0.53% of the total studied). The magnitude of interference varied, but in 23 of 28 patients (82%), it was considered large enough to have a potentially adverse effect on cost and/or the clinical care of these patients. Two cases, described in detail, illustrate the adverse effect of error on patient care and cost, and the second highlights the difficulties and limitations of current approaches for identifying interference and inaccuracy in immunoassays. CONCLUSIONS: Because millions of TSH/gonadotropin tests are carried out in UK hospital laboratories alone, our data suggest that thousands of patients could be adversely affected by errors from interferences. Early identification of interference in cases with unusual results could be valuable.
Authors:
Adel A A Ismail; Paul L Walker; Julian H Barth; Kryzsztof C Lewandowski; Rick Jones; William A Burr
Related Documents :
16123969 - Quality assurance, efficiency indicators and cost-utility of the evaluation workup for ...
16368049 - Predictors of high-cost managed care patients with acute coronary syndrome.
9284189 - The urological management of men with lower urinary tract symptoms, recorded using an i...
3861669 - Characteristics of dental teaching patients.
2104669 - Economies of scale, physician volume for neurosurgery patients, and the diagnosis-relat...
20031009 - Cost and resource utilization comparisons of second-generation antihistamines vs. monte...
18302319 - Frontotemporal dementia: a clinically complex diagnosis.
950629 - Demonstration of articular effusions and popliteal cysts with ultrasound.
10078749 - Gch1 mutation in a patient with adult-onset oromandibular dystonia.
Publication Detail:
Type:  Case Reports; Journal Article    
Journal Detail:
Title:  Clinical chemistry     Volume:  48     ISSN:  0009-9147     ISO Abbreviation:  Clin. Chem.     Publication Date:  2002 Nov 
Date Detail:
Created Date:  2002-10-30     Completed Date:  2002-11-07     Revised Date:  2004-11-17    
Medline Journal Info:
Nlm Unique ID:  9421549     Medline TA:  Clin Chem     Country:  United States    
Other Details:
Languages:  eng     Pagination:  2023-9     Citation Subset:  IM    
Affiliation:
Department of Clinical Biochemistry, at Pinderfields General Hospital, Mid Yorkshire Hospitals NHS Trust, Wakefield, West Yorkshire WF1 4DG, United Kingdom. dr.ismail@panp-tr.northy.nhs.uk
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Aged
Aged, 80 and over
Antibodies, Heterophile / blood
False Positive Reactions
Female
Gonadotropins / blood*
Humans
Immunoassay
Male
Middle Aged
Prospective Studies
Reference Values
Thyrotropin / blood*
Chemical
Reg. No./Substance:
0/Antibodies, Heterophile; 0/Gonadotropins; 9002-71-5/Thyrotropin
Comments/Corrections
Comment In:
Clin Chem. 2002 Nov;48(11):1871-2   [PMID:  12406970 ]

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Effects of temperature on stability of blood homocysteine in collection tubes containing 3-deazaaden...
Next Document:  Clinical performance of an in-line, ex vivo point-of-care monitor: a multicenter study.