Will they fit? Development of a measurement device to assess body habitus compatibility with MRI bore diameter for emergency trauma imaging.
MedLine Citation:
PMID:  22198736     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
Excessive obesity poses a significant limitation to radiographic magnetic resonance imaging (MRI), particularly related to aperture or bore diameter due to the patient's girth. Determination of whether a patient will fit into the bore of the MRI scanner is currently accomplished using patient height, weight, and MRI technician experience. These simple methods have proven unreliable. We sought to develop a device and method which could accurately determine whether a patient would fit into the MRI scanner. We developed an MRI template prototype which was tested against the standard radiology methods in a pilot study (n = 6). We then performed a prospective validation study in adult human volunteers (n = 100) to assess the accuracy of the MRI template. We collected height, weight, shoulder and pelvis girth/diameter for each study participant to evaluate the body dimension measurements that would assist in determination of whether a patient would fit into the MRI scanner. Using the MRI template, we determined that 11 of the 100 study participants would not fit in the MRI scanner and 10 were confirmed to not fit into the MRI aperture [positive predictive value (PPV) 0.91 (0.58-0.99); negative predictive value (NPV) 1.00 (0.95-1.00), sensitivity 1.00 (0.69-1.00), specificity 0.99 (0.93-0.99), likelihood ratio positive test 90 (12.81-632), likelihood ratio negative test 0, accuracy 99%]. In comparison, the body measurement method did not perform as well [PPV 0.66 (0.34-0.90), NPV 0.97 (0.92-0.99), sensitivity 0.80 (0.44-0.97), specificity 0.95 (0.89-0.98), likelihood ratio positive test 17.97 (6.56-49.2), likelihood ratio negative test 0.209 (0.06-0.72), accuracy 94%]. This study confirmed that the use of an MRI template is an accurate tool in determining whether an obese patient can fit through the MRI bore and be accommodated in the MRI scanner.
Authors:
Amanda Corwin; Adam Aresty; Suzanne Chong; Melissa Brunsvold; James R Evans; R Brent Gillespie; Lena M Napolitano
Related Documents :
11143246 - Distortion in magnetic resonance images obtained for stereotactic localization. case re...
21780166 - Magnetic resonance imaging following interstim®: an institutional experience with imag...
16000256 - Locating chronically implanted subdural electrodes using surface reconstruction.
20172796 - A fast and efficient method to compensate for brain shift for tumor resection therapies...
21302776 - Monte carlo calculation of imaging doses from diagnostic multidetector ct and kilovolta...
12637306 - Black holes on mr images of the brain of patients with björk-shiley heart valves: addi...
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2011-12-24
Journal Detail:
Title:  Emergency radiology     Volume:  -     ISSN:  1438-1435     ISO Abbreviation:  -     Publication Date:  2011 Dec 
Date Detail:
Created Date:  2011-12-26     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  9431227     Medline TA:  Emerg Radiol     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Affiliation:
Division of Acute Care Surgery, Department of Surgery, University of Michigan, Room 1C421 University Hospital 1500 East Medical Drive, 48109-0033, Ann Arbor, MI, USA.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Mating Disruption of Guatemalan Potato Moth Tecia Solanivora by Attractive and Non-Attractive Pherom...
Next Document:  Validation of prostate cancer risk-related loci identified from genome-wide association studies usin...