Document Detail


Width of the articular cartilage of the hip: quantification by using fat-suppression spin-echo MR imaging in cadavers.
MedLine Citation:
PMID:  1632354     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
OBJECTIVE: Use of MR imaging to measure the width of the articular cartilage has not been thoroughly investigated. The value of a selective fat-suppression spin-echo sequence in the quantitative assessment of articular cartilage of the hip was studied in cadavers. MATERIALS AND METHODS: Sagittal and coronal images were acquired in 10 cadaveric hips (age range at time of death, 62-81 years). On the coronal and sagittal MR images that were closest to the center of the femoral head, marks were placed every 30 degrees, with the midpoint of the femoral head used as a reference. Cartilage thickness was measured in 123 resulting locations. Sixty-three positions included both femoral and acetabular cartilages, and 60 positions included femoral cartilage without an acetabular counterpart. The findings were compared with corresponding anatomic sections. RESULTS: For the 60 locations containing only femoral cartilage, significant correlation between MR and anatomic sections was found (Pearson correlation coefficient = .34, p = .0089). Of the 63 locations containing both femoral and acetabular cartilages, the two cartilage layers could be differentiated on the MR images in 50 locations. In these 50, the MR and anatomic measurements of the femoral cartilage correlated significant (r = .58, p less than or equal to .0001). Measurements of the acetabular cartilage in these 50 locations yielded no significant correlation (r = .25, p = .08). When the entire cartilage (femoral plus acetabular) was measured in all 63 locations, the correlation between MR and anatomic measurements was .29 (p = .02). The correlation coefficients obtained in this investigation indicate considerable scattering of the data. CONCLUSION: Our results show that measurements of articular cartilage thickness of the hip on fat-suppression spin-echo MR images are not sufficiently accurate to be of clinical value.
Authors:
J Hodler; D Trudell; M N Pathria; D Resnick
Related Documents :
18412554 - Evaluation of dark circles of the lower eyelid: comparison between reflectance meters a...
22310524 - Cta combined with ct perfusion for assessing the efficacy of anti-angiogenic therapy in...
19159984 - T2 mapping of articular cartilage of glenohumeral joint with routine mri correlation--i...
3714994 - Magnetic resonance imaging of joint disease.
16161084 - Sensitivity encoding (sense) for contrast-enhanced 3d mr angiography of the abdominal a...
8423724 - Magnetization transfer imaging of the abdomen at 0.1 t: detection of hepatic neoplasms.
Publication Detail:
Type:  In Vitro; Journal Article; Research Support, Non-U.S. Gov't; Research Support, U.S. Gov't, Non-P.H.S.    
Journal Detail:
Title:  AJR. American journal of roentgenology     Volume:  159     ISSN:  0361-803X     ISO Abbreviation:  AJR Am J Roentgenol     Publication Date:  1992 Aug 
Date Detail:
Created Date:  1992-08-18     Completed Date:  1992-08-18     Revised Date:  2010-03-24    
Medline Journal Info:
Nlm Unique ID:  7708173     Medline TA:  AJR Am J Roentgenol     Country:  UNITED STATES    
Other Details:
Languages:  eng     Pagination:  351-5     Citation Subset:  AIM; IM    
Affiliation:
Department of Radiology, Veterans Affairs Medical Center, San Diego, CA 92161.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Aged
Aged, 80 and over
Cartilage, Articular / anatomy & histology*
Hip Joint / anatomy & histology*
Humans
Magnetic Resonance Imaging / methods*
Middle Aged
Reference Values

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Radiologic findings of diseases involving the maxilla and mandible.
Next Document:  The cruciate ligaments of the knee: correlation between MR appearance and gross and histologic findi...