Document Detail


Waveform descriptor for pulse onset detection of intracranial pressure signal.
MedLine Citation:
PMID:  21807549     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
We present an algorithm to identify the onset of intracranial pressure (ICP) pulses. The algorithm creates a waveform descriptor to extract the feature of each local minimum of the waveform and then identifies the onset by comparing the feature with a customized template. The waveform descriptor is derived by transforming the vectors connecting a given point and the local waveform samples around it into log-polar coordinates and ranking them into uniform bins. Using an ICP dataset consisting of 40933 normal beats and 306 segments of artifacts and noise, we investigated the performance of our algorithm (waveform descriptor, WD), global minimum within a sliding window (GM) and two other algorithms originally proposed for arterial blood pressure (ABP) signal (slope sum function, SSF and pulse waveform delineator, PUD). As a result, all the four algorithms showed good performance and WD showed overall better one. At a tolerance level of 30ms (i.e., the predicted onset and ground truth were considered as correctly matched if the distance between the two was equal or less than 30ms), WD achieved a sensitivity of 0.9723 and PPV of 0.9475, GM achieved a sensitivity of 0.9226 and PPV of 0.8968, PUD achieved a sensitivity of 0.9599 and PPV of 0.9327 and SSF, a sensitivity of 0.9720 and PPV of 0.9136. The evaluation indicates that the algorithms are effective for identifying the onset of ICP pulses.
Authors:
Li Yang; Mingxi Zhao; Chenglin Peng; Xiao Hu; Hua Feng; Zhong Ji
Related Documents :
10668779 - Catecholamine-induced hypertension in lumbosacral paraplegia: five case reports.
8150809 - Spectral analysis of blood pressure and heart rate variability in response to stress fr...
7963779 - Effect of clonidine on postpartum shivering after epidural analgesia: a randomized, con...
1683249 - Studies with abanoquil (uk-52,046) a novel quinoline alpha 1-adrenoceptor antagonist: i...
7899259 - Histamine-independent modulation of the neuropeptide y-induced pressor response by alph...
6273179 - Use of labetalol in hypertensive patients during discontinuation of clonidine therapy.
2316669 - Glomerulotubular balance in a mathematical model of the proximal nephron.
8289979 - The older hypertensive. assessment and treatment.
20670959 - Importance of dynamic dyssynchrony in the occurrence of hypertensive heart failure with...
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2011-7-30
Journal Detail:
Title:  Medical engineering & physics     Volume:  -     ISSN:  1873-4030     ISO Abbreviation:  -     Publication Date:  2011 Jul 
Date Detail:
Created Date:  2011-8-2     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  9422753     Medline TA:  Med Eng Phys     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Copyright Information:
Copyright © 2011 IPEM. Published by Elsevier Ltd. All rights reserved.
Affiliation:
111 Project Laboratory of Biomechanics and Tissue Repair, Bioengineering College, Chongqing University, Chongqing 400030, China.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Biomechanical analysis of the effects of implant diameter and bone quality in short implants placed ...
Next Document:  Epidemiology and characteristics of antimicrobial resistance in China.