Document Detail


Virtual axis finder: a new method to determine the two kinematic axes of rotation for the tibio-femoral joint.
MedLine Citation:
PMID:  20524747     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
The tibio-femoral joint has been mechanically approximated with two fixed kinematic axes of rotation, the longitudinal rotational (LR) axis in the tibia and the flexion-extension (FE) axis in the femur. The mechanical axis finder developed by Hollister et al. (1993, "The Axes of Rotation of the Knee," Clin. Orthop. Relat. Res., 290, pp. 259-268) identified the two fixed axes but the visual-based alignment introduced errors in the method. Therefore, the objectives were to develop and validate a new axis finding method to identify the LR and FE axes which improves on the error of the mechanical axis finder. The virtual axis finder retained the concepts of the mechanical axis finder but utilized a mathematical optimization to identify the axes. Thus, the axes are identified in a two-step process: First, the LR axis is identified from pure internal-external rotation of the tibia and the FE axis is identified after the LR axis is known. The validation used virtual simulations of 3D video-based motion analysis to create relative motion between the femur and tibia during pure internal-external rotation, and flexion-extension with coupled internal-external rotation. The simulations modeled tibio-femoral joint kinematics and incorporated 1 mm of random measurement error. The root mean squared errors (RMSEs) in identifying the position and orientation of the LR and FE axes with the virtual axis finder were 0.45 mm and 0.20 deg, and 0.11 mm and 0.20 deg, respectively. These errors are at least two times better in position and seven times better in orientation than those of the mechanical axis finder. Variables, which were considered a potential source of variation between joints and/or measurement systems, were tested for their sensitivity to the RMSE of identifying the axes. Changes in either the position or orientation of a rotational axis resulted in high sensitivity to translational RMSE (6.8 mm of RMSE per mm of translation) and rotational RMSE (1.38 deg of RMSE per degree of rotation), respectively. Notwithstanding these high sensitivities, corresponding errors can be reduced by segmenting the range of motion into regions where changes in either position or orientation are small. The virtual axis finder successfully increased the accuracy of the mechanical axis finder when the axes of motion are fixed with respect to the bones, but must be used judiciously in applications which do not have fixed axes of rotation.
Authors:
Michelle Roland; M L Hull; S M Howell
Related Documents :
19889417 - Differences in patellofemoral contact mechanics associated with patellofemoral pain syn...
24318557 - Chemical composition and efficacy of cephalic gland secretion ofarmitermes chagresi (is...
10710007 - Use of robotic technology for diathrodial joint research.
3335577 - Limits of movement in the human knee. effect of sectioning the posterior cruciate ligam...
10976967 - Hemifield visual motion stimulation: an example of interhemispheric crosstalk.
23615927 - Morphology-controlled preparation and enhanced simulated sunlight and visible-light pho...
Publication Detail:
Type:  Journal Article; Research Support, Non-U.S. Gov't    
Journal Detail:
Title:  Journal of biomechanical engineering     Volume:  132     ISSN:  1528-8951     ISO Abbreviation:  J Biomech Eng     Publication Date:  2010 Jan 
Date Detail:
Created Date:  2010-06-07     Completed Date:  2010-09-30     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  7909584     Medline TA:  J Biomech Eng     Country:  United States    
Other Details:
Languages:  eng     Pagination:  011009     Citation Subset:  IM    
Affiliation:
Biomedical Engineering Program, One Shields Ave., University of California, Davis, CA 95616, USA.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Algorithms*
Arthrometry, Articular / methods*
Computer Simulation
Humans
Knee Joint / anatomy & histology*,  physiology*
Models, Anatomic*
Models, Biological*
Range of Motion, Articular / physiology*

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Engineering silicone rubbers for in vitro studies: creating AAA models and ILT analogues with physio...
Next Document:  Age-dependent regional mechanical properties of the rat hippocampus and cortex.